Maintenance

1.It is important to keep the burner and the burner compartment clean. This must be done periodically, at least once per season.

2.Clean the brass trim using a soft clean cloth, slightly dampened with lemon oil and buff with a soft clean cloth. DO NOT use brass polish or household clean- ers as these products will damage the brass trim. Lemon oil can be obtained at supermarkets or hard- ware stores.

3.Periodically check and clean the air circulating blower wheel of any debris. Blower motors are prelubricated for extended bearing life. No further lubrication is required. WARNING: Disconnect power before servicing the air circulating blower.

4.The air filter should be inspected monthly and re- placed when necessary with a 16" x 16" x 1" filter.

5.When servicing, check all electrical wiring for loose connections.

WARNING: Disconnect power before serv- icing.

6.Contact your local representative to arrange an an- nual service program.

Cleaning the Standing

Pilot Control System

The burner and control system consist of:

burner tube

gas orifice

pilot assembly

thermopile

millivolt gas valve

Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician.

1.Turn off pilot light at gas valve.

2.Allow fireplace to cool if it has been operating.

3.Remove window frame assembly. (Refer to Window Frame Assembly Removal section.)

4.Remove logs.

5.Vacuum burner compartment especially around orifice primary air openings.

6.Visually inspect pilot. Brush or blow away any dust or lint accumulation.

7.Reinstall logs.

8.Ignite pilot - Refer to Lighting Instructions.

9.Reinstall window frame assembly.

To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not lifting or floating.

Typically, the top 3/8” to 1/2” (10mm or 13mm) of the thermopile should be engulfed in the pilot flame. (Refer to Page 21, Figure 40)

To adjust pilot burner: (by qualified service technician)

1.Remove pilot adjustment cap

2.Adjust pilot screw to provide properly sized flame.

3.Replace pilot adjustment cap.

The primary air shutter is set at factory and should only be adjusted, if necessary, by a qualified service technician.

10001195

25

Image 25
Contents Rear Direct Vent Model DVHVAC36 Table of Contents Please Review the Following Carefully Installation & Operating InstructionsDVHVAC36 Fireplace DimensionsLocating Your Gas Fireplace Unit AssemblyClearance to Combustibles Supply Air Duct Systems Framing and FinishingMantel Return Air PlenumFinal Finishing Gas Line InstallationHearth Gas Inlet & Manifold PressuresElectrical Specifications Typical gas supply installationGeneral Venting ElectricalLocation of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes Twist Lock PipesCorner Installation How to Use the Vent GraphRear Wall Installations Sidewall Venting GraphLocate vent opening on wall Vertical Sidewall Applications+ B = 17 5.2m Max Zero clearance sleeve is only required for combustible walls Vertical Sidewall InstallationsAlways install Horizontal vent Ing on a level Plane Below Grade InstallationVertical Through-the-Roof Applications Vertical Through-the-Roof InstallationTypical Ceil Twist Lock Venting Components Operating Instructions Flame Adjustment Setting Temperature RiseFlame Characteristics Lava RockInspecting the Venting System Ceramic Refractory InstallationInspecting the Venting/Heating Exchange System Mortar lines must be alignedTo Turn Off Gas To Heater Lighting & Operating InstructionsWhat to do if YOU Smell GAS SIT Nova 825 Millivolt Valve Troubleshooting the Gas Control SystemCleaning the Standing Pilot Control System MaintenanceDescription DVHVAC36DVHVAC36 Decorative Bay Window Optional AccessoriesDo not remove existing window frame as- sembly Remove all plastic from brass trimsDVHVAC36 Page Product Covered by this Warranty Limited Lifetime WarrantyAFUE% Efficiency Ratings