DVHVAC36
Troubleshooting the Gas Control System
SIT NOVA 825 Millivolt Valve
NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "ON" position.
SYMPTOM | POSSIBLE CAUSES | CORRECTIVE ACTION |
1. Spark ignitor will not light | A. Defective or misaligned | Using a match, light pilot. If pilot lights, turn off |
| electrode at pilot. | pilot and push the red button again. If pilot will not |
|
| light - check gap at electrode and |
|
| 1/8" to have a strong spark. |
|
|
|
| B. Defective ignitor (Push Button) | Push Piezo Ignitor Button. Check for spark at |
|
| electrode and pilot. If no spark to pilot, and elec |
|
| trode wire is properly connected, replace ignitor. |
2. Pilot will not stay lit after | A. Defective pilot generator | Check pilot flame. Must impinge on thermo- |
carefully following lighting | (thermocouple) | couple/thermopile. Note: this pilot burner assem |
instructions. |
| bly utilizes |
|
| The thermocouple operates the main valve |
|
| operation (On and Off). Clean and or adjust pilot for |
|
| maximum flame impingement on thermopile and |
|
| thermocouple. |
|
|
|
| B. Defective automatic valve | Turn valve knob to “Pilot”. Maintain flow to pilot; |
|
| millivolt meter should read greater than 10 mV. If |
|
| the reading is okay and the pilot does not stay on, |
|
| replace the gas valve. Note: An interrupter block |
|
| (not supplied) must be used to conduct this test. |
3. Pilot burning, no gas to | A. Thermostat or wires defective | Check wall switch and wires for proper connections. |
main burner, Valve knob |
|
|
|
| |
"ON", thermostat "ON" | B. Thermopile may not be | 1. Be sure wire connections from thermopile at |
| generating sufficient | gas valve terminals are tight and thermopile is |
| millivoltage. | fully inserted into pilot bracket. |
|
| 2. One of the wall switch wires may be grounded. |
|
| Remove wall switch wires from valve terminals if |
|
| pilot now stays lit, trace wall switch wiring for |
|
| ground. May be grounded to fireplace or gas |
|
| supply. |
|
| 3. Check thermopile with millivolt meter. Take |
|
| reading at thermopile terminals of gas valve. |
|
| Should read 325 millivolts while holding valve |
|
| knob depressed in pilot position and wall switch |
|
| “Off”. Replace faulty thermopile if reading is below |
|
| specified minimum. |
|
|
|
| C. Plugged burner orifice. | Check burner orifices for debris and remove. |
|
|
|
| D. Defective automatic valve | Turn valve knob to “On”, place wall switch to “On” |
| operator. | millivolt meter should read greater than 100 mV. If |
|
| the reading is okay and the burner does not come |
| E. Transformer defective. | on, replace the gas valve. |
|
| |
| F. Power Not ON. |
|
| G. heat demand satisfied. |
|
4. Frequent pilot outage | A. Pilot flame may be too low | Clean and/or adjust pilot flame for maximum flame |
problem. | or blowing (high) causing the | impingement on thermopile and thermocouple. |
| pilot safety to drop out. |
|
|
|
|
| B. Possible blockage of the vent | Check the vent terminal for blockage |
| terminal. |
|
|
|
|