Vermont Casting 3030 Catalytic Combustor, Remove the Combustor Module, Clean the Combustor Module

Page 21
Catalytic Combustor

Vermont Castings UVS27 Vent-Free Gas Heater

Catalytic Combustor

The combustor should be cleaned annually to ensure optimal performance. Follow the procedure below.

Remove the Combustor Module

1.Be sure the heater is COLD.

2.Remove the top grille, screen and top plate. (Fig. 35)

3.Use the phillips screwdriver to remove the two sheet metal screws and washers that secure the combus- tor to the top of the firebox. (Fig. 36)

Clean the Combustor Module

1.Clean the outer surface of the filter with the brush attachment of your vacuum cleaner to remove loose dirt.

2.Submerge the filter in a mild soapy water solution. Rinse thoroughly with distilled water.

3.Replace in heater when dry.

Replace The Combustor Module

1.Set combustor on top of flat surface of firebox. Secure with the two sheet metal screws and wash- ers.

2.Replace the top plate, screen and grille.

ST114a

Fig. 35 Remove top plate, grille and screen.

ST709a

Fig. 36 Remove the catalytic combustor module.

20005004

21

Image 21
Contents WHATTO DO IF YOU SMELL GAS Homeowner’s InstallationDo not try to light any appli- ance INSTALLER / CONSUMER SAFETY INFORMATIONTable Of Contents Vermont Castings UVS27 Vent-FreeGas Heater20005004 Installation & Operating Instructions Vermont Castings UVS27 Vent-FreeGas Heater20005004 Vermont Castings UVS27 Vent-FreeGas Heater Shell Dimensions20005004 Freestanding StoveMinimum Clearances to Combustible Materials Clearance RequirementsHearth Requirements Vermont Castings UVS27 Vent-FreeGas HeaterGas Inlet and Manifold Pressures Gas SpecificationsUVS27R & UVS27M Vent-Free Certified to ANSI Z21.11.2a-2001 Unvented HeatersFresh Air Requirements for Combustion Vent Free Featuresand Ventilation Provide For Adequate VentilationVermont Castings UVS27 Vent-FreeGas Heater W A R N I N GW A R N I N G 20005004Shell / Firebox Assembly Assembly ProceduresUnpack the Firebox Vermont Castings UVS27 Vent-FreeGas HeaterInstall Optional Fan Kit Vermont Castings UVS27 Vent-FreeGas Heater20005004 Install ON/OFF Switch Vermont Castings UVS27 Vent-FreeGas Heater20005004 Thermostat Connection Optional Glass & Catalyst InstallationVermont Castings UVS27 Vent-FreeGas Heater 20005004Connect the Gas Supply Line Vermont Castings UVS27 Vent-FreeGas Heater20005004 Install Log Set Vermont Castings UVS27 Vent-FreeGas Heater20005004 Complete the Installation Vermont Castings UVS27 Vent-FreeGas Heater20005004 Flame Characteristics Flame & Temperature AdjustmentOperation Your First FireLighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTINGLighting Instructions To Turn Off Gas To HeaterCONDITION TroubleshootingPOSSIBLE CAUSE Vermont Castings UVS27 Vent-FreeGas HeaterVermont Castings UVS27 Vent-FreeGas Heater Troubleshooting cont’dCONDITION POSSIBLE CAUSEFirebox Cleaning and Inspection MaintenanceCleaning Procedure Glass ReplacementCatalytic Combustor Clean the Combustor ModuleRemove the Combustor Module Replace The Combustor ModuleUVS27R, UVS27M Vent Free Gas Heaters ModelsVermont Castings UVS27 Vent-FreeGas Heater 20005004Models 3030, 3031, 3032, 3033 continued UVS27R, UVS27M Vent Free Gas HeatersVermont Castings UVS27 Vent-FreeGas Heater 20005004Vermont Castings UVS27 Vent-FreeGas Heater UVS27R, UVS27M Vent Free Gas HeatersModels 3030, 3031, 3032, 3033 continued Shell Enamel Part Numbers - HearthmountRemote Controls Optional Accessories AvailableFan Kits Glass / Catalyst Kit UVGODCFKPRODUCT COVERED BY THIS WARRANTY LIMITED LIFETIME WARRANTYIF WARRANTY SERVICE IS NEEDED… Vermont Castings UVS27 Vent-FreeGas Heater