Vermont Casting 3033, 3030, 3031, 3032 manual Operation, Your First Fire, Pilot and Burner Inspection

Page 16
Operation

Vermont Castings UVS27 Vent-Free Gas Heater

Operation

Your First Fire

Read these instructions carefully and familiarize yourself with the burner controls shown on Page 18. Locate the pilot assembly, Figure 28. Follow the lighting instructions on Page 17 exactly.

During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within the first eight to ten hours, however, you can open a window to provide fresh air to alleviate the condition.

Pilot and Burner Inspection

Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figures 31 and 32. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the heater until the pilot flame is correct.

Follow regular maintenance procedures as described on Page 20.

Natural

Pilot

LP Pilot

ST673

Fig. 28 Pilot assembly location.

Flame & Temperature Adjustment

RN/RP Models

For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ adjustment knob located near the center of the gas control valve. (Fig. 29, 30)

16

Turn

 

 

 

counterclockwise

LO

HI

Turn clockwise

to decrease

 

to increase

 

 

flame height

 

 

flame height

 

 

 

HV102

 

 

 

 

Fig. 29 Flame adjustment knob for Honeywell Valve.

SIT 630

Turn

counterclockwise

 

HI

Turn clockwise

 

 

 

OFF

to decrease

to increase

 

LO

PILOT

flame height

flame height

 

 

 

 

 

 

 

 

HV117

Fig. 30 Flame adjustment knob for Eurosit Valve.

Flame Characteristics

It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the pictorial illustrated below. (Fig. 31, 32) If the flame patterns appear abnormal contact a qualified service provider for service and adjustment.

 

ST198

Fig. 31

Correct pilot flame appearance.

 

LG225

Fig. 32

Correct burner flame pattern.

 

20005004

Image 16
Contents Homeowner’s Installation WHATTO DO IF YOU SMELL GASDo not try to light any appli- ance INSTALLER / CONSUMER SAFETY INFORMATIONVermont Castings UVS27 Vent-FreeGas Heater Table Of Contents20005004 Vermont Castings UVS27 Vent-FreeGas Heater Installation & Operating Instructions20005004 Shell Dimensions Vermont Castings UVS27 Vent-FreeGas Heater20005004 Freestanding StoveClearance Requirements Minimum Clearances to Combustible MaterialsHearth Requirements Vermont Castings UVS27 Vent-FreeGas HeaterGas Specifications Gas Inlet and Manifold PressuresUVS27R & UVS27M Vent-Free Certified to ANSI Z21.11.2a-2001 Unvented HeatersVent Free Features Fresh Air Requirements for Combustionand Ventilation Provide For Adequate VentilationW A R N I N G Vermont Castings UVS27 Vent-FreeGas HeaterW A R N I N G 20005004Assembly Procedures Shell / Firebox AssemblyUnpack the Firebox Vermont Castings UVS27 Vent-FreeGas HeaterVermont Castings UVS27 Vent-FreeGas Heater Install Optional Fan Kit20005004 Vermont Castings UVS27 Vent-FreeGas Heater Install ON/OFF Switch20005004 Glass & Catalyst Installation Thermostat Connection OptionalVermont Castings UVS27 Vent-FreeGas Heater 20005004Vermont Castings UVS27 Vent-FreeGas Heater Connect the Gas Supply Line20005004 Vermont Castings UVS27 Vent-FreeGas Heater Install Log Set20005004 Vermont Castings UVS27 Vent-FreeGas Heater Complete the Installation20005004 Flame & Temperature Adjustment Flame CharacteristicsOperation Your First FireFOR YOUR SAFETY READ BEFORE LIGHTING Lighting and Operating InstructionsLighting Instructions To Turn Off Gas To HeaterTroubleshooting CONDITIONPOSSIBLE CAUSE Vermont Castings UVS27 Vent-FreeGas HeaterTroubleshooting cont’d Vermont Castings UVS27 Vent-FreeGas HeaterCONDITION POSSIBLE CAUSEMaintenance Firebox Cleaning and InspectionCleaning Procedure Glass ReplacementClean the Combustor Module Catalytic CombustorRemove the Combustor Module Replace The Combustor ModuleModels UVS27R, UVS27M Vent Free Gas HeatersVermont Castings UVS27 Vent-FreeGas Heater 20005004UVS27R, UVS27M Vent Free Gas Heaters Models 3030, 3031, 3032, 3033 continuedVermont Castings UVS27 Vent-FreeGas Heater 20005004UVS27R, UVS27M Vent Free Gas Heaters Vermont Castings UVS27 Vent-FreeGas HeaterModels 3030, 3031, 3032, 3033 continued Shell Enamel Part Numbers - HearthmountOptional Accessories Available Remote ControlsFan Kits Glass / Catalyst Kit UVGODCFKLIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTYIF WARRANTY SERVICE IS NEEDED… Vermont Castings UVS27 Vent-FreeGas Heater