Install Optional Fan Kit

Vermont Castings UVS27 Vent-Free Gas Heater

Right

Side

Wingbolt

ST105

Fig. Secure right side to the back panel.

5.Lift the firebox assembly as a unit and slide it back to position it within the shell. The base of the firebox should rest on the side support shelves as in Figures 7 and 9. The side plates interlock with the firebox by use of a pair of steel tabs that engage with the ribs on the base of the firebox. (Fig. 9) Properly posi- tioned, the firebox will be level and locked in place. If not, adjust the levelling screws as required to keep the entire assembly level.

Steel Tab

Manual background Side Plate

Screw & Washer

Back Panel

Side

Plate Manual background

Support Shelf

ST106

ST125

Fig. 9 Install the firebox assembly,. Be sure steel tabs engage ribs on base of firebox.

Install Optional Fan Kit

1.

Attach the fan to the firebox by engaging the upper

 

flange of the fan skirt under the lower edge of the

 

shroud and secure the skirt with the four screws and

 

one star washer provided. (Fig. 10, 11)

2.

Feed the snapstat wire lead up between the inner

 

and outer rear shroud panels and secure the

 

snapstat to the upper right side of the inner shroud.

 

(Fig. 12)

Fig. 7 The sides must be at right angles to the back panel in order for the firebox to fit properly.

4.Connect the gas supply line to the burner control valve before you install the firebox. This may be a flexible line, (not supplied), or hard plumbing.

1/2” Gas Supply

1/2” NPT x 1/2” Flare Shutoff

Valve

3/8” Flex Line

(from Valve)

FP297a

Fig. 8 Typical gas supply installation.

3.

Secure the snapstat wire harness to the shroud

 

panel using the wire tie provided.

4.

Route the rheostat control switch and wire forward

 

under the stove. Use the wire tie to secure the fan

 

and rheostat wire harnesses together to the tubing

 

under the bottom heat shield.

5.

Install the rheostat onto the bracket to the left of the

 

valve. (Fig. 13)

10

20005004

Image 10
Contents Do not try to light any appli- ance Homeowner’s InstallationWHATTO DO IF YOU SMELL GAS INSTALLER / CONSUMER SAFETY INFORMATIONVermont Castings UVS27 Vent-FreeGas Heater Table Of Contents20005004 Vermont Castings UVS27 Vent-FreeGas Heater Installation & Operating Instructions20005004 20005004 Shell DimensionsVermont Castings UVS27 Vent-FreeGas Heater Freestanding StoveHearth Requirements Clearance RequirementsMinimum Clearances to Combustible Materials Vermont Castings UVS27 Vent-FreeGas HeaterUVS27R & UVS27M Vent-Free Certified to Gas SpecificationsGas Inlet and Manifold Pressures ANSI Z21.11.2a-2001 Unvented Heatersand Ventilation Vent Free FeaturesFresh Air Requirements for Combustion Provide For Adequate VentilationW A R N I N G W A R N I N GVermont Castings UVS27 Vent-FreeGas Heater 20005004Unpack the Firebox Assembly ProceduresShell / Firebox Assembly Vermont Castings UVS27 Vent-FreeGas HeaterVermont Castings UVS27 Vent-FreeGas Heater Install Optional Fan Kit20005004 Vermont Castings UVS27 Vent-FreeGas Heater Install ON/OFF Switch20005004 Vermont Castings UVS27 Vent-FreeGas Heater Glass & Catalyst InstallationThermostat Connection Optional 20005004Vermont Castings UVS27 Vent-FreeGas Heater Connect the Gas Supply Line20005004 Vermont Castings UVS27 Vent-FreeGas Heater Install Log Set20005004 Vermont Castings UVS27 Vent-FreeGas Heater Complete the Installation20005004 Operation Flame & Temperature AdjustmentFlame Characteristics Your First FireLighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTINGLighting and Operating Instructions To Turn Off Gas To HeaterPOSSIBLE CAUSE TroubleshootingCONDITION Vermont Castings UVS27 Vent-FreeGas HeaterCONDITION Troubleshooting cont’dVermont Castings UVS27 Vent-FreeGas Heater POSSIBLE CAUSECleaning Procedure MaintenanceFirebox Cleaning and Inspection Glass ReplacementRemove the Combustor Module Clean the Combustor ModuleCatalytic Combustor Replace The Combustor ModuleVermont Castings UVS27 Vent-FreeGas Heater ModelsUVS27R, UVS27M Vent Free Gas Heaters 20005004Vermont Castings UVS27 Vent-FreeGas Heater UVS27R, UVS27M Vent Free Gas HeatersModels 3030, 3031, 3032, 3033 continued 20005004Models 3030, 3031, 3032, 3033 continued UVS27R, UVS27M Vent Free Gas HeatersVermont Castings UVS27 Vent-FreeGas Heater Shell Enamel Part Numbers - HearthmountFan Kits Optional Accessories AvailableRemote Controls Glass / Catalyst Kit UVGODCFKIF WARRANTY SERVICE IS NEEDED… LIMITED LIFETIME WARRANTYPRODUCT COVERED BY THIS WARRANTY Vermont Castings UVS27 Vent-FreeGas Heater