Vermont Casting 3030, 3033 Clearance Requirements, Minimum Clearances to Combustible Materials

Page 5
Clearance Requirements

Vermont Castings UVS27 Vent-Free Gas Heater

Clearance Requirements

Minimum Clearances to

Combustible Materials

Maintain clearance, (empty space), between combus- tible materials and the heater as specified below for the appropriate firebox shell being installed.

Freestanding Stove

D

B Minimum Clearances toHearth RequirementsA Manual backgroundManual background C

 

 

ST101

Hearthmount

 

 

 

 

D

B

A

C

 

 

ST102

A: Mantel/Trim* ......................... 35” (889mm) / 2” (51mm)

B: Side Wall/Trim* ............................................. 2” (51mm)

C: Rear Wall ........................................................ 0” (0mm)

D: Max. Mantel Width .................................... 13” (330mm)

Alcove Clearances

B

 

 

 

B

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

ST103

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

A: Ceiling

35” (889mm)

B: Side Wall

2” (51mm)

C: Rear Wall

0” (0mm)

D: Max. Alcove Depth

13” (330mm)

 

A

 

 

 

 

B

 

 

 

C

 

 

S

D

 

 

T

E

 

 

 

 

 

U

 

F

 

V

 

G

 

 

W

 

 

 

 

 

X

H

 

 

 

Y

 

 

 

Z

 

 

 

ST599a

 

Mantel

 

Mantel from

Ref.

Shelf Depth

Ref.

Stove Top

A

13” (330mm)

S

35” (889mm)

B

11¹⁄₄” (286mm)

T

30” (762mm)

C

9³⁄₈” (241mm)

U

25” (635mm)

D

7¹⁄₂” (191mm)

V

20” (508mm)

E

5³⁄₄” (146mm)

W

15” (381mm)

F

4” (102mm)

X

10” (254mm)

G

2¹⁄₄” (57mm)

Y

5” (127mm)

H

1” (25mm)

Z

2” (51mm)

Hearth Requirements

The Freestanding Stove and Hearthmount Shell must be installed on rigid flooring. If the appliance is in- stalled on any combustible surface other than wood flooring, such as carpet or tile, a metal or wood panel must be installed to extend the full length and width of the unit.

WARNING

Do not install this heater in a bathroom or bedroom.

Installation of this heater must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 / NFPA54.

This heater creates warm air currents. These currents move heat to wall surfaces next to the heater. Installing the heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air such as tobacco smoke exist, may discolor walls.

Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

20005004

5

Image 5
Contents WHATTO DO IF YOU SMELL GAS Homeowner’s InstallationDo not try to light any appli- ance INSTALLER / CONSUMER SAFETY INFORMATION20005004 Table Of ContentsVermont Castings UVS27 Vent-FreeGas Heater 20005004 Installation & Operating InstructionsVermont Castings UVS27 Vent-FreeGas Heater Vermont Castings UVS27 Vent-FreeGas Heater Shell Dimensions20005004 Freestanding StoveMinimum Clearances to Combustible Materials Clearance RequirementsHearth Requirements Vermont Castings UVS27 Vent-FreeGas HeaterGas Inlet and Manifold Pressures Gas SpecificationsUVS27R & UVS27M Vent-Free Certified to ANSI Z21.11.2a-2001 Unvented HeatersFresh Air Requirements for Combustion Vent Free Featuresand Ventilation Provide For Adequate VentilationVermont Castings UVS27 Vent-FreeGas Heater W A R N I N GW A R N I N G 20005004Shell / Firebox Assembly Assembly ProceduresUnpack the Firebox Vermont Castings UVS27 Vent-FreeGas Heater20005004 Install Optional Fan KitVermont Castings UVS27 Vent-FreeGas Heater 20005004 Install ON/OFF SwitchVermont Castings UVS27 Vent-FreeGas Heater Thermostat Connection Optional Glass & Catalyst InstallationVermont Castings UVS27 Vent-FreeGas Heater 2000500420005004 Connect the Gas Supply LineVermont Castings UVS27 Vent-FreeGas Heater 20005004 Install Log SetVermont Castings UVS27 Vent-FreeGas Heater 20005004 Complete the InstallationVermont Castings UVS27 Vent-FreeGas Heater Flame Characteristics Flame & Temperature AdjustmentOperation Your First FireLighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTINGLighting Instructions To Turn Off Gas To HeaterCONDITION TroubleshootingPOSSIBLE CAUSE Vermont Castings UVS27 Vent-FreeGas HeaterVermont Castings UVS27 Vent-FreeGas Heater Troubleshooting cont’dCONDITION POSSIBLE CAUSEFirebox Cleaning and Inspection MaintenanceCleaning Procedure Glass ReplacementCatalytic Combustor Clean the Combustor ModuleRemove the Combustor Module Replace The Combustor ModuleUVS27R, UVS27M Vent Free Gas Heaters ModelsVermont Castings UVS27 Vent-FreeGas Heater 20005004Models 3030, 3031, 3032, 3033 continued UVS27R, UVS27M Vent Free Gas HeatersVermont Castings UVS27 Vent-FreeGas Heater 20005004Vermont Castings UVS27 Vent-FreeGas Heater UVS27R, UVS27M Vent Free Gas HeatersModels 3030, 3031, 3032, 3033 continued Shell Enamel Part Numbers - HearthmountRemote Controls Optional Accessories AvailableFan Kits Glass / Catalyst Kit UVGODCFKPRODUCT COVERED BY THIS WARRANTY LIMITED LIFETIME WARRANTYIF WARRANTY SERVICE IS NEEDED… Vermont Castings UVS27 Vent-FreeGas Heater