CFM Corporation 2467, 2468 manual Troubleshooting / Honeywell #8420 Gas Control System

Page 15

Dutchwest Natural Vent Gas Heater

Troubleshooting / Honeywell #8420 Gas Control System

NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position.

WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK.

SYMPTOM

POSSIBLE CAUSES

CORRECTIVE ACTION

1.

Spark ignitor will

A. Defective or misaligned

Using a match, light [ilot. If pilot lights, turn off pilot and

 

not light

electrode at the pilot

push the ignitor button again. If pilot will not light, check

 

 

 

gap at electrode and pilot - it should be 1/8” to have a

 

 

 

strong spark.

 

 

 

 

 

 

 

 

B. Defective ignitor (push

Push piezo ignitor button. Check for spark at electrode

 

 

button)

and pilot. If there is no spark at the pilot, and electrode

 

 

 

wire is properly connected, replace ignitor.

2.

Pilot will not stay lit

A. Defective pilot generator

Check pilot flame. It must impinge on the thermocouple

 

 

after carefully

(thermocouple)

or thermopile. NOTE: This pilot burner assembly uses

 

following the

 

both a thermocouple adn a thermopile. The thermo-

 

lighting instructions

 

couple operates the pilot flame. Tighten the thermo-

 

 

 

couple. The thermopile operates the main valve. (ON

 

 

 

and OFF) Clean and/or adjust pilot for maximum flame

 

 

 

impingement on thermocouple and thermopile.

 

 

B. Defective automatic valve

Turn valve knob to “Pilot”. Maintain flow to pilot; millivolt

 

 

 

operator

mete should read greater than 10mV. If the reading is

 

 

 

okay and the pilot does not stay on, replace the gas

 

 

 

valve. NOTE: An interrupter block (not supplied) must

 

 

 

be used to conduct this test.

 

 

 

 

 

 

 

C.Defective safety switch

Check the continuity accross the safety limit switch with

 

 

 

the unit cold. If there is no continuity, the safety switch

 

 

 

needs to be replaced.

 

 

 

 

3. Pilot lights, no gas

A. Remote switch or wires

Check rocker switch and wires for proper connection

 

to burner, valve

defective

Use jumper wires across terminals at rocker switch. If

 

knob ON, remote

 

burner lights, replace rocker switch. If okay, use jumper

 

switch (rocker

 

wires across rocker switch wires at the valve. If burner

 

switch) ON

 

lights, wires are faulty or connections are bad.

 

 

B. Thermopile may not gen-

1. Be sure wire connecitons from thermopile at gas

 

 

 

ate sufficient voltage

valve terminals are tight and thermopile is fully inserted

 

 

 

into pilot bracket.

 

 

 

2. One of the rocker switch wires may be grounded

 

 

 

Remove rocker switch wire form valve termianls. If

 

 

 

burner now stays lit, trace rocker switch wiring from

 

 

 

ground. It may be grounded to the appliance of the

 

 

 

gas supply line.

 

 

 

3. Check the thermopile with a millivolt meter. Take

 

 

 

reading at thermopile (“TP” and “TP/TH”) terminals of

 

 

 

gas valve. Should read 325 millivolts minimum while

 

 

 

holding valve knob depressed in PILOT position and

 

 

 

with rocker switch OFF. Replace faulty thermopile if

 

 

 

reading is below specified minimum.

 

 

C. Plugged burner orifice

Check burner orifices for debris, and remove.

 

 

 

D. Defective automatic valve

Turn knob to ON, place rocker switch to ON. Millivolt

 

 

 

operator

meter should read greater than 10mV. If the reading is

 

 

 

okay and the burner does not light, replace the valve.

4. Frequent pilot

A. Pilot flame may be too low

Clean and/or adjust pilot flame for maximum flame

 

 

outage

or high, (blowing or lifting).

impingement on thermocouple and thermopile.

 

 

causing the pilot to drop out

 

 

 

 

 

B. Possible blockage of the

Check the vent termianl for blockage.

 

 

vent terminal

 

 

 

 

 

 

 

 

 

30002008

15

Image 15
Contents Dutchwest Table of Contents Installation & Operating Instructions Dutchwest dimensions Dutchwest Natural Vent Gas Heater DimensionsHearth Requirements Parallel Installation Minimum Clearance Flue CenterlineAlcove Minimum Dimensions Ceiling ClearancesVenting Requirements and Options Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsVenting Requirements Passing Through a Combustible Wall or CeilingAttach the fan assembly to the fan bracket Install the Optional FanVenting System Assembly Connect the Gas Supply Line Thermostat Connection optional Install ON/OFF SwitchInstall the Log Set Burner InformationInstall the back, left and right logs Install the Stove FrontOperation Your First FirePilot and Burner Inspection What to do if YOU Smell GAS To Turn Off Gas To HeaterSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemConversion Precautions Conversion ProcedureFuel Conversion Instructions Remove pilot hood Injector Orifice Size Matrix Conversion to Natural Gas Input BTU/h Air ShutterConversion to LP Input BTU/h Air Shutter Maintenance Check the Gas Flame Regularly Gasket ReplacementStove Disassembly Inspect the Vent System AnnuallyBLK Wiring DiagramsTPH Description Part NumberFuel Conversion Kits Dutchwest Natural Vent Gas HeaterDecorative Rings Optional Accessories AvailableRemote Controls Fan KitsDutchwest Natural Vent Gas Heater If Warranty Service is NEEDED… Product Covered by this WarrantyProduit Couvert PAR LA Présente Garantie SI UN Service Sous Garantie EST REQUIS…CFM Specialty Home Products

2468, 2467, 2468 specifications

CFM Corporation has established itself as a powerhouse in the aviation industry, particularly through the design and manufacture of high-performance aircraft engines. Among its standout products are the CFM 2468 and 2467 engines, which have garnered attention for their state-of-the-art features, innovative technologies, and impressive performance characteristics.

The CFM 2468 engine is known for its remarkable efficiency and reliability. One of its primary features is the advanced fuel efficiency technology that minimizes fuel consumption while maximizing thrust. This is largely attributed to the inclusion of next-generation composites in the engine's fan blades and cases, which contribute to a lighter overall weight without compromising durability. As a result, operators benefit from lower operating costs, making the 2468 engine a cost-effective choice for airlines.

On the other hand, the CFM 2467 engine has been engineered with a focus on reducing noise pollution and emissions. This engine incorporates cutting-edge noise-reducing technologies, including a redesigned inlet and an innovative exhaust system that reduces noise levels significantly during operation. This makes the 2467 an ideal solution for airports in urban areas where noise regulations are stringent. Furthermore, the engine's environmentally friendly design complies with the latest emissions standards, which is increasingly important in today's aviation market.

Both engines utilize advanced digital technologies, including the latest in engine health monitoring systems. These systems provide real-time data analytics to operators, allowing for predictive maintenance and minimizing downtime. This technological integration not only enhances operational efficiency but also helps in extending the lifespan of the engines.

In terms of operational characteristics, both the CFM 2468 and 2467 engines are built to perform under a wide range of conditions. Their robust design ensures they can withstand various environmental challenges, from extreme temperatures to high humidity. Additionally, their modular design simplifies maintenance procedures, allowing for quicker turnaround times.

In summary, the CFM Corporation 2468 and 2467 engines exemplify the company's commitment to innovation, efficiency, and sustainability. With their advanced technologies and impressive features, these engines are set to redefine performance standards in the aviation industry, making them a preferred choice for airlines globally.