CFM Corporation 2467, 2468 manual Installation & Operating Instructions

Page 3

Dutchwest Natural Vent Gas Heater

Installation & Operating Instructions

The Dutchwest Natural Vent Room Heater, Model Nos. 2467 and 2468, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for Vented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Alti- tudes.

The installation of the Dutchwest Natural Vent Room Heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition and CSA B-149.1 Installation Code. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pres- sure at 3.5 inches w.c. for Natural Gas and 10 inches w.c. for LP gas at maximum input.)

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

Installation and replacement of gas piping, gas utilization equipment or accessories, and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) installation or replacement of gas piping, or (b), the connection, installation, repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction.

The Dutchwest Natural Vent Room Heater should be inspected before use and at least annually by a qualified service agency. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.

The Dutchwest Natural Vent Room Heater and its individual shut-off valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The Dutchwest Natural Vent Room Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply pip- ing system at test pressures equal to or less than 1/2 psig.

An accessible tap is located above the pilot/on-off knob for checking the inlet pressure.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

This appliance must be properly connected to a listed 4” (100mm) Type B venting system or to an approved masonry or factory-built chimney system. In Canada, a complete reline of Class A chimneys is required. This heater is equipped with a vent safety shutoff system.

This appliance must be properly connected to a venting system. WARNING: Operation of this heater when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possible death.

This appliance is approved for bedroom installations in the U.S. and Canada.

This appliance may be installed in an aftermarket* manufac- tured (mobile) home, where not prohibited by state or local codes.

The Dutchwest Natural Vent Room Heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, (latest edition), or of the current Canadian Elec- trical Code C22.1.

Due to high temperatures this appliance should be located out of traffic and away from furniture and draperies.

WARNING: This appliance is hot while in operation. Keep children, clothing, and furniture away. Contact may cause burns or ignition of combustible materials.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance.

Clothing or other flammable materials should not be placed on or near the appliance.

Any safety screen, glass or guard removed for servicing an appliance must be replaced prior to operating the appliance.

The appliance area must be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

The flow of combustion and ventilation air must not be obstructed. The installation must include adequate accessibility and clearance for servicing and proper operation.

WARNING: Do not operate the Room Heater with the glass panel removed, cracked or broken. Replacement of the panel should be done by a licensed or qualified service person.

Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Do not burn wood, trash or any other material for which this appliance was not designed. This appliance is designed to burn either natural gas or propane only.

This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

*Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer.

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

30002008

3

Image 3
Contents Dutchwest Table of Contents Installation & Operating Instructions Dutchwest dimensions Dutchwest Natural Vent Gas Heater DimensionsHearth Requirements Parallel Installation Minimum Clearance Flue CenterlineAlcove Minimum Dimensions Ceiling ClearancesVenting Requirements and Options Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsVenting Requirements Passing Through a Combustible Wall or CeilingAttach the fan assembly to the fan bracket Install the Optional FanVenting System Assembly Connect the Gas Supply Line Thermostat Connection optional Install ON/OFF SwitchInstall the Log Set Burner InformationInstall the back, left and right logs Install the Stove FrontOperation Your First FirePilot and Burner Inspection What to do if YOU Smell GAS To Turn Off Gas To HeaterSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemConversion Precautions Conversion ProcedureFuel Conversion Instructions Remove pilot hood Injector Orifice Size Matrix Conversion to Natural Gas Input BTU/h Air ShutterConversion to LP Input BTU/h Air Shutter Maintenance Check the Gas Flame Regularly Gasket ReplacementStove Disassembly Inspect the Vent System AnnuallyBLK Wiring DiagramsTPH Description Part NumberFuel Conversion Kits Dutchwest Natural Vent Gas HeaterDecorative Rings Optional Accessories AvailableRemote Controls Fan KitsDutchwest Natural Vent Gas Heater If Warranty Service is NEEDED… Product Covered by this WarrantyProduit Couvert PAR LA Présente Garantie SI UN Service Sous Garantie EST REQUIS…CFM Specialty Home Products

2468, 2467, 2468 specifications

CFM Corporation has established itself as a powerhouse in the aviation industry, particularly through the design and manufacture of high-performance aircraft engines. Among its standout products are the CFM 2468 and 2467 engines, which have garnered attention for their state-of-the-art features, innovative technologies, and impressive performance characteristics.

The CFM 2468 engine is known for its remarkable efficiency and reliability. One of its primary features is the advanced fuel efficiency technology that minimizes fuel consumption while maximizing thrust. This is largely attributed to the inclusion of next-generation composites in the engine's fan blades and cases, which contribute to a lighter overall weight without compromising durability. As a result, operators benefit from lower operating costs, making the 2468 engine a cost-effective choice for airlines.

On the other hand, the CFM 2467 engine has been engineered with a focus on reducing noise pollution and emissions. This engine incorporates cutting-edge noise-reducing technologies, including a redesigned inlet and an innovative exhaust system that reduces noise levels significantly during operation. This makes the 2467 an ideal solution for airports in urban areas where noise regulations are stringent. Furthermore, the engine's environmentally friendly design complies with the latest emissions standards, which is increasingly important in today's aviation market.

Both engines utilize advanced digital technologies, including the latest in engine health monitoring systems. These systems provide real-time data analytics to operators, allowing for predictive maintenance and minimizing downtime. This technological integration not only enhances operational efficiency but also helps in extending the lifespan of the engines.

In terms of operational characteristics, both the CFM 2468 and 2467 engines are built to perform under a wide range of conditions. Their robust design ensures they can withstand various environmental challenges, from extreme temperatures to high humidity. Additionally, their modular design simplifies maintenance procedures, allowing for quicker turnaround times.

In summary, the CFM Corporation 2468 and 2467 engines exemplify the company's commitment to innovation, efficiency, and sustainability. With their advanced technologies and impressive features, these engines are set to redefine performance standards in the aviation industry, making them a preferred choice for airlines globally.