Drolet 7000 MVRLC, 36C03U TYPE 139 manual Distance between valve

Page 10
Distance between valve

-Install the wall switch in a convenient location. Route a proper sized wire from the switch or the thermostat to the gas valve.

Distance between valve

Wire gage

and switch

 

8’

22

12’

20

20’

18

32’

16

50’

14

- Connect the wires in serial with the face plate flame switch ( green wires ).

NOTE : DO NOT CONNECT THE WALL SWITCH WIRE OR THE VALVE TO 120 VOLTS POWER SUPPLY LINE. THE VALVE IS OPERATED BY ITS OWN MILLIVOLT SYSTEM.

19.If you want to turn the main burner ON and OFF using a wireless remote control, install the remote control module apart from the gas valve and as close to the front as possible. Connect the wires as shown.

9

Image 10
Contents FIREPLACE GAS INSERT INSTALLATION AND OPERATING INSTRUCTIONSFOR YOUR SAFETY FOR YOUR SAFETYTABLE OF CONTENTS GENERAL INFORMATION KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCEDO NOT MODIFY THIS APPLIANCE SPECIFICATIONS TOP, SIDE AND FRONT VIEWS INSTALLATION 11.Secure the liner to the 4” connector on the top of the ULTRA FLAME with three metal screws WARNING DO NOT USE OPEN FLAME TO CHECK LEAKS Distance between valve 25.Install a cap on the liner GLASS FRONT REMOVAL CLEANING AND INSTALLATION BURNER REMOVAL AND INSTALLATION LOG INSTALLATION FACE PLATE ASSEMBLY AND INSTALLATION INSTALLATIONS REFRACTORY PANELS INSTALLATIONS EMBERS KIT INSTALLATIONSSHUTDOWN INSTRUCTIONS OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONSFAN OPERATION MAINTENANCE INSTRUCTIONS PILOT BURNER ADJUSTMENTREPLACEMENT PARTS OPTIONAL PARTSLIMITED 5 YEARS WARRANTY