OPERATING INSTRUCTIONS

LIGHTING INSTRUCTIONS :

1.Open the bottom louvers of the face plate to reach the control.

2.Turn the gas valve knob to the “OFF” position and wait 5 minutes.

Note : You have to depress the gas valve knob to turn from “PILOT” to “OFF” or from “OFF” to “PILOT”.

3.Turn the gas valve knob to “PILOT”.

4.Depress and hold the knob while lighting the pilot by pressing the pilot igniter button (RED button ). Keep the knob depressed for about 1 minute. Release the knob. The pilot should continue to burn by itself, if not, repeat step 4.

Note : You may need to press the pilot igniter button more than one time to light the pilot.

5.Turn the gas valve knob to the “ON” position.

6.Turn the face place mounted switch to the “ON” position. If you don’t have an additional wall switch , the main burner will come on. Otherwise, turn the wall switch to “ON” if you want the main burner to come on.

7.The other knob controls the gas flow and the power of the appliance.

SHUTDOWN INSTRUCTIONS

Main burner only : Turn off the face plate switch ( or wall switch ).

To relight the main burner, turn the switch on ( or the wall switch )

Pilot and Main burners : Turn the gas valve to the “OFF” position. Depress the knob to pass from the “PILOT” to “OFF” position.

FAN OPERATION :

To turn the air blower “ON” or “OFF”, activate the face plate switch connected to the yellow wires. The fan will not start if the appliance is cold. Operate the gas insert for at least 15 minutes to heat up the thermo-switch. The fan will also turn itself off about 20 minutes after extinction of the main flame.

Note: The speed control must also be on to allow fan to work.

17

Image 18
Contents FIREPLACE GAS INSERT INSTALLATION AND OPERATING INSTRUCTIONSFOR YOUR SAFETY FOR YOUR SAFETYTABLE OF CONTENTS GENERAL INFORMATION KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCEDO NOT MODIFY THIS APPLIANCE SPECIFICATIONS TOP, SIDE AND FRONT VIEWS INSTALLATION 11.Secure the liner to the 4” connector on the top of the ULTRA FLAME with three metal screws WARNING DO NOT USE OPEN FLAME TO CHECK LEAKS Distance between valve 25.Install a cap on the liner GLASS FRONT REMOVAL CLEANING AND INSTALLATION BURNER REMOVAL AND INSTALLATION LOG INSTALLATION FACE PLATE ASSEMBLY AND INSTALLATION INSTALLATIONS REFRACTORY PANELS INSTALLATIONS EMBERS KIT INSTALLATIONSOPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS SHUTDOWN INSTRUCTIONSFAN OPERATION MAINTENANCE INSTRUCTIONS PILOT BURNER ADJUSTMENTREPLACEMENT PARTS OPTIONAL PARTSLIMITED 5 YEARS WARRANTY