Drolet 36C03U TYPE 139, 7000 MVRLC manual Specifications

Page 5

SPECIFICATIONS :

Dimensions :

 

 

 

 

 

height :

20”

 

 

 

width :

28”

 

 

 

depth :

15”

 

 

 

face plate :

44 5/16” x 27 1/2”

 

 

 

glass :

14 1/2 x 30 5/16

1400° F clear ceramic

Fuel :

 

Natural Gas

Propane

 

Input :

30 000

26 000 Btu/h

 

Manifold pressure :

3.5

11

in w.c.

 

Min inlet pressure :

5

11

in w.c.

 

Max inlet pressure :

7

14

in w.c.

Vent size :

4” Diam. listed gas liner

 

 

Valve :

Natural gas

Propane

 

 

 

White Rogers

Robertshaw

 

 

 

Model 36C03U TYPE 139 Model 7000 MVRLC

 

 

Millivolt operated

Millivolt operated

 

 

SIT

SIT

 

 

 

Nova model

Nova model

 

 

 

Millivolt operated

Millivolt operated

 

Blower :

Variable speed, 140 CFM

 

 

Thermo-switch : 120° F “ON” 110° F “OFF” bi-metal type

Efficiency : 74% heating

Clearances to combustibles :

mantel : 10” from top of face place

side wall : 0” from side of face plate

4

Image 5
Contents FOR YOUR SAFETY INSTALLATION AND OPERATING INSTRUCTIONSFIREPLACE GAS INSERT FOR YOUR SAFETYTABLE OF CONTENTS KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE GENERAL INFORMATIONDO NOT MODIFY THIS APPLIANCE SPECIFICATIONS TOP, SIDE AND FRONT VIEWS INSTALLATION 11.Secure the liner to the 4” connector on the top of the ULTRA FLAME with three metal screws WARNING DO NOT USE OPEN FLAME TO CHECK LEAKS Distance between valve 25.Install a cap on the liner GLASS FRONT REMOVAL CLEANING AND INSTALLATION BURNER REMOVAL AND INSTALLATION LOG INSTALLATION FACE PLATE ASSEMBLY AND INSTALLATION INSTALLATIONS EMBERS KIT INSTALLATIONS REFRACTORY PANELS INSTALLATIONSFAN OPERATION OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONSSHUTDOWN INSTRUCTIONS PILOT BURNER ADJUSTMENT MAINTENANCE INSTRUCTIONSOPTIONAL PARTS REPLACEMENT PARTSLIMITED 5 YEARS WARRANTY