8. SPECIFICATIONS

Power Source

12 V DC (AC adapter)

Current Consumption

150 mA

 

 

Slave Remote Controller

RS-485, screwless connector

 

 

Camera Control

RS-485, screwless connector

Switcher Control

RS-485, screwless connector

 

RS-232C, D-sub connector (9 pins, male)

 

 

Alarm Input

RS-232C, D-sub connector (9 pins, male)

 

 

Alarm Output / Control Input

Alarm output: 16 channels, NPN open collector output,

 

withstand voltage: 30 V DC, control current: 20 mA

 

Alarm input: 1 channel, no-voltage make contact input,

 

open coltage: 5 V DC, short-circuit current: 5 mA max.

 

Home position selection input: 1 channel, no-voltage make contact input,

 

open voltage: 5 V DC,

 

short-circuit current: 5 mA max.

 

D-sub connector (25 pins, female)

Display

LED indication of control status, alarm status, alarm hold status,

 

still picture status, defroster, auxiliary setting, auto panning, and lens speed

 

LCD indication of key entry confirmation

 

 

Alarm Signal

Continuous alarm tone (can be turned on and off)

 

 

Number of Unit Connections

Up to 2 (one to be set for MASTER unit, another for SLAVE unit)

Maximum Cable Distance

1.2 km* (between the Remote controller and the Combination cameras)

 

 

Operating Temperature

0 to +50°C

 

 

Operating Humidity

Under 90% (no due condensation produced)

Finish

Panel: Surface-treated steel plate, sand gray, paint

 

Sides: Rubber

 

 

Dimensions

326 (w) x 62 (h) x 185.2 (d) mm

 

 

Weight

1.8 kg (AC adapter excluded)

*Applies to the system where the unit and Combination camera are connected in a matched pair. Represents the total of connected cable distances if multiple Combination cameras or Interface units are connected in the system (when the CPEV-S cable thicker than 0.65 mm in diameter is used).

Note: The design and specifications are subject to change without notice for improvement.

• Accessories

 

D-sub connector (9 pins, male)

1

D-sub connector (25 pins, male)

1

C-RM500 complies with Part 15 of the FCC Rules.

Note

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Modifications

Any modifications made to this device that are not approved by TOA Corporation may void the authority granted to the user by the FCC to operate this equipment.