6.4.4. Automatic reset

Enables the function that automatically resets the camera to a fixed position if the camera is not operated for a preset time interval.

Step 1. Press the Menu key to display the menu screen.

Step 2. Tilt the joystick up or down to select "AUTO RETURN" and confirm it with the SET key. The setting will appear on Line 2.

A U T O R E T U R N 1 . O N

Step 3. Tilt the joystick left or right to select either of the following settings and confirm it with the SET key.

[Setting contents]

1. ON

Confirming this setting displays the screen for setting the time interval before Automatic

 

Reset occurs following camera operation.

 

A U T O

R E T U R N

 

1 . O N

1

0 S E C

Tilt the joystick left or right to select the reset interval: "10 SEC," "15 SEC," "20 SEC," "30 SEC," "1 MIN," "2 MIN," "3 MIN," "4 MIN" and "5 MIN." The selected time is confirmed with the SET key.

Note: "SEC" stands for seconds, and "MIN" for minutes.

2. OFF

Disables the Automatic Reset function.

Note: This selection is set to "2. OFF" by the factory.

27

Page 27
Image 27
TOA Electronics C-RM500 operating instructions T O R E T U R N 1 . O N, T O T U R N, E C, Automatic reset