6.4.6. I/O speed
Sets each control terminal's transfer rate.
Step 1. Press the Menu key to display the menu screen.
Step 2. Tilt the joystick up or down to select "I/O SPEED" then press the SET key to confirm the selection.
The screen for selecting the control terminal is displayed.
Step 3. Tilt the joystick left or right to select the control terminal. Select the control terminal from "CAMERA," "SWCHER" (switcher), "REMOTE" (Remote Control Unit), and "ALARM."
I / O S P E E D
2
I / O S P E E D
SET
C A M E R A
Step 4. Press the SET key to confirm the selected control terminal. The transfer rate is shown on Line 2. In this event, the current setting is displayed.
Step 5. Tilt the joystick left or right to select the transfer rate.
The transfer rate can be selected from "2400," "4800," "9600," "19200," and "38400."
Note
Set the same transfer rate as those of equipment connected to each control terminal.
Control Terminal | Factory Setting |
Camera | 38400 bps |
|
|
Switcher | 19200 bps |
Remote control unit | 19200 bps |
|
|
Alarm | 38400 bps |
3
I / O S P E E D
4
I/ O S P E E D
3 8 4 0 0
| UP |
LEFT | RIGHT |
| DOWN |
R E M O T E
SET
R E M O T E
Step 6. Press the SET key to confirm the set transfer rate.
The procedure returns to Step 3, and the settings are displayed on the LCD screen.
Step 7. To further set other control terminals, repeat Steps 3 – 6.
To return to the display of the setting item, press the Clear key.
5
I/ O S P E E D
1 9 2 0 0
6
| UP |
LEFT | RIGHT |
| DOWN |
R E M O T E
SET
29