7.2. Connection to Combination Cameras
Connect the Combination camera's control cable to the unit's Camera Control terminal, making sure to match their polarities.
C-RM500  (Operation mode: "MASTER")
Camera control terminal  | 
GND  | 
Shielded 
A  | 
  | 1  | 
  | ||
B  | 
  | 2  | 
  | ||
A  | 
  | 3  | 
  | ||
  | 
B4
5
Video output cable
Camera control cable  | 
  | 
  | 
  | Monitor TV  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Combination camera
[Connection cables]
•Recommended cable type: 
•The maximum cable distance between the unit and the Combination camera is 1.2 km when connected in a matched pair. If multiple cameras are connected to a system, the maximum distance between connected equipment is 1.2 km in total.
Remote Controller
a
Combination
camera
b
Combination
camera
c
Combination
camera
a + b + c < 1.2 km
[Connected Camera Termination Switch Setting]
Make sure that the termination switches of the cameras connected to the system are set as follows.
Cameras other than the last connected camera: Termination switch OFF
Last connected camera:  | Termination switch ON  | 
Remote Controller
Combination
camera
Terminal switch
OFF
Combination
camera
Terminal switch
OFF
Combination
camera
Terminal switch
ON