7.2. Connection to Combination Cameras

Connect the Combination camera's control cable to the unit's Camera Control terminal, making sure to match their polarities.

C-RM500 (Operation mode: "MASTER")

Camera control terminal

GND

Shielded twisted-pair cable

A

 

1

 

B

 

2

 

A

 

3

 

 

B4

5

Video output cable

Camera control cable

 

 

 

Monitor TV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination camera

[Connection cables]

Recommended cable type: CPEV-S type (shielded twisted-pair cable) thicker than 0.65 mm in diameter.

The maximum cable distance between the unit and the Combination camera is 1.2 km when connected in a matched pair. If multiple cameras are connected to a system, the maximum distance between connected equipment is 1.2 km in total.

Remote Controller

C-RM500

a

Combination

camera

b

Combination

camera

c

Combination

camera

a + b + c < 1.2 km

[Connected Camera Termination Switch Setting]

Make sure that the termination switches of the cameras connected to the system are set as follows.

Cameras other than the last connected camera: Termination switch OFF

Last connected camera:

Termination switch ON

Remote Controller

C-RM500

Combination

camera

Terminal switch

OFF

Combination

camera

Terminal switch

OFF

Combination

camera

Terminal switch

ON

43