TOA Electronics C-RM500 Sequence key *1, *2, CH call key *1, *2, Menu key, LCD screen, SET key

Models: C-RM500

1 52
Download 52 pages 2.4 Kb
Page 7
Image 7

7.4-segment split-screen key *1, *2

Displays camera images in the 4-segment split- screen format. Subsequent depressions of this key can cycle through 4 separate groups of 4- segment split-screen displays.

8.Sequential 4-segment split-screen key *1 Sequentially cycles through all connected camera outputs of up to 4 groups of cameras at a preset time interval. Program sequencing and viewing intervals are set at the Smart Switcher when connected.

9.Group selector key *1, *2

Switches on-screen camera groups during 4-, 9- or 10-segment split-screen display.

10.Sequence key *1, *2

Sequences all connected camera outputs to the full screen at the specified time interval. (Viewing intervals are set at the switcher.)

11.CH call key *1, *2

Displays the camera number on the monitor for a preset period of time. This key is convenient for finding the camera number when no indication or only the camera name is displayed.

12.Menu key

Displays the menu on the Remote Controller's LCD screen for setting functions. To enable, press lightly with a pointed object. When the menu is opened and the desired item is selected, the screen under the setting will be displayed. Pressing the key again will close the setting screen and the display will disappear.

13.LCD screen

Displays character information for the setting menu, numeric keypad input status, current operation, etc.

14.Zoom key *3

Sets the Combination camera's zoom lens for "TELESCOPE" or "WIDE ANGLE" operation. The Zoom key can only be used while the Control indicator is on.

15.Focus key *3

Sets the Combination camera's zoom lens for "FAR" or "NEAR" operation. The Focus key can only be used while the Control indicator is on.

16.Lens speed key / Indicator *3

Adjusts the speed of lens operation when the Zoom or Focus key is pressed.

17.Joystick *3

Controls the attached pan/tilt head's horizontal and vertical movement. The joystick can only be used while the Control indicator is on.

18.Numeric keypad [0 – 9]

Used to enter the camera number, position number, abbreviated number, etc.

19.Clear key [C]

Used to correct entry errors. Also, turns off the buzzer when sounded by an activated alarm.

20.SET key

Used in conjunction with the numeric keypad to program the camera number or position number. Also, if pressed after entering the set abbreviated number with the numeric key, the camera image corresponding to that number can be displayed on the monitor.

21.Wiper key *3

Remotely controls the outdoor-use Combination camera's wiper. This key can only be used while the Control indicator is on.

22.Defroster key/Indicator *3

Remotely controls the outdoor-use Combination camera's defroster. This key can only be used while the Control indicator is on.

23.Auxiliary contact key / Indicator *3

Controls (makes or breaks) the Combination camera's Auxiliary Contact Output 1. The indicator is on when auxiliary contact is at make, and off when the contact is at break. This key can only be used when the Control indicator is on.

24.Auto key / Indicator *3

Enables or disables the Combination camera's automatic functions (Auto-Pan, Auto-Trace, and Preset Sequence). The Auto key can only be used when the Control indicator is on.

Auto-Pan

Automatically pans a camera pan/tilt head.

Auto-Trace

Automatically executes manual camera operations stored in memory.

Preset Sequence

Automatically sequences camera positions in the order of preset position numbers.

25.Auto-focus key / Indicator *3

Enables the Combination camera's Auto-Focus function. This key can only be used when the Control indicator is on.

26.Freeze screen key / Indicator *1, *2

Freezes camera images. However, sequential displays cannot be made still. The indicator flashes when there is a freeze image on the screen.

7

Page 7
Image 7
TOA Electronics C-RM500 Sequence key *1, *2, CH call key *1, *2, Menu key, LCD screen, Zoom key *3, Focus key *3, SET key