7.6. Alarm Output/Control Input Terminal Connections

7.6.1. Pin functions

Shown below are the numbers and names of the Alarm I/O terminal pins.

C-RM500

Alarm output / control input terminal

13

1

25

14

Pin No.

Function

Pin No.

Function

1

Ground

14

Alarm Output 10

 

 

 

 

2

Alarm Output 1

15

Alarm Output 11

 

 

 

 

3

Alarm Output 2

16

Alarm Output 12

4

Alarm Output 3

17

Ground

 

 

 

 

5

Ground

18

Alarm Output 13

 

 

 

 

6

Alarm Output 4

19

Alarm Output 14

7

Alarm Output 5

20

Alarm Output 15

 

 

 

 

8

Alarm Output 6

21

Alarm Output 16

 

 

 

 

9

Ground

22

Alarm Output

10

Alarm Output 7

23

Alarm Input

 

 

 

 

11

Alarm Output 8

24

Home Position Selection Input

 

 

 

 

12

Alarm Output 9

25

Auxiliary Input

13

Ground

 

 

 

 

 

 

[Alarm Output Terminal] (Pin No. 1 – 16)

The terminal of the number corresponding to the alarm-activated camera number shorts with the ground terminal. Alarm output terminals 1 – 16 are the NPN open collector output.

Operating current: Maximum 20 V, 20 mA

[Alarm Output Terminal] (Pin No. 22)

This terminal is shorted with the ground terminal even when only one of the alarm input terminals receives an alarm signal. The alarm output terminal is the NPN open collector output.

Operating current: Maximum 20 V, 20 mA

[Alarm Input Terminal] (Pin No. 23)

Shorting this terminal with the ground terminal when "OTHER16," "OTHER16-64" or "OTHER" has been selected in the "SWITCHER" setting will sound a buzzer and cause the Alarm Reset indicator to flash while it is shorted. (Refer to p. 25 "Switchers.")

Open voltage: 5 V DC, short-circuit current: Maximum 5 mA

[Home Position Selection Input Terminal] (Pin No. 24)

When Auto-Return is performed while this terminal is being shorted to the ground terminal, the camera's operation follows the setting made for "2" in the "Home position" setting. (Refer to p. 28 "Home position.")

Open voltage: 5 V DC, short-circuit current: Maximum 5 mA

[Auxiliary Input] (Pin No. 25) Leave this input unconnected.

Open voltage: 5 V DC, short-circuit current: Maximum 5 mA