Waterford Appliances E61-NG, E61-LP New screws E supplied with the kit. Tighten screws securely

Page 10

INSTALLATION

the new screws (E) supplied with the kit. Tighten screws securely.

9)Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit.

3)Remove the door by lifting it slightly up and off the front face. Remove the 7 nuts that secure the front glass bracket holding the center glass in place.

Remove the 7 nuts holding the Front Glass

Bracket to the front face.

CAUTION: Don't let the glass drop.

4)Carefully remove the logs and embers.

5)Remove burner. See diagram below.

Note: Use a magnetic type screwdriver if possible.

Pilot assembly is now accessible for

steps 6) to 11).

8) Pull off the pilot cap to expose the pilot orifice.

6)Remove and discard the 3 pressure regu- lator mounting screws (A), pressure regu- lator tower (B) and diaphragm (C).

7)Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pres- sure regulator assembly to the valve using

10)Remove burner orifice with a 1/2" wrench and discard. Use a wrench to hold on to the elbow behind the orifice.

11)Reinstall new burner orifice LP stamped #50 and tighten.

12)Reverse steps 5) to 1).

13)Attach the label (Part#: 908-455) "This unit has been converted to Propane" on top of the Serial # decal.

14)Replace yellow "Natural Gas" label with red "Propane" label

15)Check for gas leaks.

16)Check inlet and outlet pressures.

17)Check operation of flame control.

18)Check for proper flame appearance and glow on logs.

10

Waterford E61 Gas Fireplace Insert

Image 10
Contents Emerald Gas Fireplace Insert Models E61-NG Natural Gas E61-LP PropaneWaterford GAS Fireplace Insert Waterford E61 Gas Fireplace InsertTable of Contents Safety Label Duplicate Serial noCertified for/Certifiée pour Canada and U.S.A Installation Clearances to Combustibles Materials RequiredFloor Protection High Elevation GAS ConnectionVenting For Emerald E61 Gas Insert Using SIT 820 Nova Gas Valve Flue Liner InstallationConversion KIT From Natural GAS to Propane Model #260-960 Pilot assembly is now accessible for Steps 6 to New screws E supplied with the kit. Tighten screws securelyGAS Pipe Pressure Testing Natural Gas Kit # Propane Kit #Shroud Installation Aeration AdjustmentValve Description Diagram LOG InstallationDiagram 1 Do not force logs down Optional Door GrillWiring Diagram Optional Remote ControlVerify proper operation after serv- icing Operating Instructions Gas Control Valve Maintenance InstructionsCopy Lighting Plate Instructions Unit Body/FireboxGlass Replacement MaintenanceLOG Replacement Cleaning FAN MaintenanceThermodisc access is through the Fan Access Panel Valve MaintenanceTo remove fan Parts List Replacement / Spare Parts ListDescription Parts List Waterford E61 Gas Fireplace Insert Warranty ConditionsRegister your Waterford online at