Waterford Appliances E61-LP Maintenance, LOG Replacement Cleaning, Gasket, Glass Replacement

Page 17
WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SUR- FACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLYSUPERVISEDWHEN THEYAREINTHESAMEROOMAS THE APPLIANCE.
CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACEDONORNEARTHEAPPLI- ANCE.
7) Each time the appliance is lit, it may cause condensation and fog the glass. This con- densation and fog is normal and will disap- pear in a few minutes as the glass heats up.

MAINTENANCE

LOG REPLACEMENT &

CLEANING

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installa- tion.

NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s perform- ance which is not covered under warranty.

Cleaning the Log Set and Firebox

2)a) Remove the 7 nuts that secure the front glass bracket holding the center glass in place.

b)If removing the side glass, remove the 2 nuts that secure the retainers holding each side glass in place.

Never operate the appliance without

During the annual inspection and maintenance

the glass properly secured in place or

appointment, the service person should clean

with the door open.

dust, lint, and any light accumulation from the

 

logs and firebox area. An extra-soft brush

8) Periodically check the pilot flames. Correct

should be use don the logs as they are extreme-

flame pattern has three strong blue flames:

ly fragile; a vacuum cleaner may be used on the

1 flowing around the thermopile and 1

firebox. See the log installation instructions for

around the thermocouple, and 1 flowing

details on removing and replacing the logs.

across the rear of the burner (it does not

 

have to be touching the burner).

DOOR AND GLASS

 

 

GASKET

Remove the 7 nuts holding the

Front Glass Bracket to the front face. CAUTION: Don't let the glass drop.

Top View of pilot flame

Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear of the burner or thermopile.

Top View of pilot flame

Note: If you have an incorrect flame pat- tern, contact your Waterford deal- er for further instructions.

If the door gasket requires replacement use only the proper replacement gasket available from your Waterford dealer.

GLASS REPLACEMENT

Your Waterford stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement from an authorized Waterford dealer only, and follow our step-by-step instructions for re- placement.

1)Remove the door by lifting it slightly up and off the front face.

3)Remove the glass and replace with the new glass.

4)Install the front glass bracket and turn the nuts just enough to support the glass. Tight- en the nuts alternately. Avoid overtighten- ing the nuts as this may damage the glass.

FAN MAINTENANCE

If your fan requires maintenance or replace- ment, access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit

MUST NOT be operated without the fan access panel securely in place and cor- rectly sealed.

IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan mo- tors on a regular basis by vacuum- ing out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

Waterford E61 Gas Fireplace Insert

17

Image 17
Contents Models E61-NG Natural Gas E61-LP Propane Emerald Gas Fireplace InsertWaterford E61 Gas Fireplace Insert Waterford GAS Fireplace InsertTable of Contents Duplicate Serial no Safety LabelCertified for/Certifiée pour Canada and U.S.A Installation Floor Protection Materials RequiredClearances to Combustibles Venting GAS ConnectionHigh Elevation Conversion KIT From Natural GAS to Propane Model #260-960 Flue Liner InstallationFor Emerald E61 Gas Insert Using SIT 820 Nova Gas Valve New screws E supplied with the kit. Tighten screws securely Pilot assembly is now accessible for Steps 6 toNatural Gas Kit # Propane Kit # GAS Pipe Pressure TestingValve Description Aeration AdjustmentShroud Installation Diagram 1 Do not force logs down LOG InstallationDiagram Optional Door GrillVerify proper operation after serv- icing Optional Remote ControlWiring Diagram Operating Instructions Copy Lighting Plate Instructions Maintenance InstructionsGas Control Valve Unit Body/FireboxLOG Replacement Cleaning MaintenanceGlass Replacement FAN MaintenanceTo remove fan Valve MaintenanceThermodisc access is through the Fan Access Panel Replacement / Spare Parts List Parts ListDescription Parts List Waterford E61 Gas Fireplace Insert Conditions WarrantyRegister your Waterford online at