Waterford Appliances E61-NG, E61-LP installation manual Safety Label, Duplicate Serial no

Page 4

4

For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve.

For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.

 

 

 

DUPLICATE SERIAL NO.

NOTE: Waterford units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

This is a copy of the label that accompanies each Waterford E61-NG Gas Insert Natural Gas. We have printed a copy of the contents here for your review. The safety label is located on the right side door panel.

205

SAFETY LABEL

Listed: VENT GAS FIREPLACE HEATER

Certified for/Certifiée pour: CANADA and U.S.A.

Report No. 476-1714-00 (Oct. 1999)

Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003, CAN/CGA 2.17-M91

FACTORY EQUIPPED FOR NATURAL GAS Model:E61NG ÉQUIPÉ A L'UISINE POUR GAZ NATURAL

DO NOT REMOVE OR COVER THIS LABEL /

NE PAS ENLEVER CETTE ÉTIQUETTE

Serial no./

205

No de serie

 

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel

Minimum supply pressure

5" WC/C.E. (1.25 kPa)

Manifold pressure High

3.8" WC/C.E. (0.94 kPa)

Manifold pressure Low

1.1" WC/C.E. (0.27 kPa)

Factory Equipped for Altitude 0-2000 ft.

Maximum Input

38,000

Btu/h (11.14 Kw/h)

Minimum Input

19,000

Btu/h (5.57 Kw/h)

Orifice size

#32 DMS

(2.9mm)

Altitude

0-2000 ft/pi

(0-610m)

Pression d'allimentation minimum

Pression à la tubulure d'échappement élevée Pression à la tubulure d'échappement basse

Débit Calorifique maximum

Débit Calorifique minimum

Dimensions de l'orifice

L'altitude

Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and

Propane Installation Codes, CSA B149.1.

FOR USE WITH GLASS DOORS CERTIFIED

WITH APPLIANCE ONLY.

This vented gas fireplace heater is

not for use with air filters. Not for use with solid fuel.

Electrical Supply (115 V, 1.13A, 60 Hz)

Approved for use with Emerald Zero Clearance Kit, Part No. 270-900.

Waterford E61 Gas

Convertible for Altitude 2000-4500 ft.

Maximum Input

36,100

Btu/h (10.57 Kw/h)

Débit Calorifique maximum

Minimum Input

18,000

Btu/h (5.28 Kw/h)

Débit Calorifique minimum

Orifice size

#33 DMS

(2.87mm)

Dimensions de l'orifice

Altitude

2000-4500 ft/pi (610-1372m)

L'altitude

Convertible to 27,000 Btu for Altitude 0 - 4500 ft. with Kit #: 260-920

Maximum Input

27,000 Btu/h (7.91 Kw/h)

Débit Calorifique maximum

Minimum Input

13,500 Btu/h (3.95 Kw/h)

Débit Calorifique minimum

Orifice size

#40 DMS

(2.49mm)

Dimensions de l'orifice

Altitude

0-4500 ft/pi

(0-1372m)

L'altitude

B

A

Minimum Clearances

to Combustibles/

Degagement Minimum

De Materiaux Combustibles

Unit to Sidewalls

A 9"/230mm

Top of Hob to mantel:

unshielded

B 16"/406mm

shielded

B 12"/305mm

To ceiling from top of stove: 36"/ 915mm

Fireplace Insert

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanenlty located,manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.

Made in Canada/Fabrique au Canada

FPI Fireplace Products International Ltd., Delta, BC, Canada

Floor Protector

A floor protector consisting of one layer of ½" thick WonderBoard , Durock , or equivalent extending at least 9" in front of the face of the unit and the full width of the front surface is required.

908-419b

Image 4
Contents Emerald Gas Fireplace Insert Models E61-NG Natural Gas E61-LP PropaneWaterford GAS Fireplace Insert Waterford E61 Gas Fireplace InsertTable of Contents Safety Label Duplicate Serial noCertified for/Certifiée pour Canada and U.S.A Installation Clearances to Combustibles Materials RequiredFloor Protection High Elevation GAS ConnectionVenting For Emerald E61 Gas Insert Using SIT 820 Nova Gas Valve Flue Liner InstallationConversion KIT From Natural GAS to Propane Model #260-960 Pilot assembly is now accessible for Steps 6 to New screws E supplied with the kit. Tighten screws securelyGAS Pipe Pressure Testing Natural Gas Kit # Propane Kit #Shroud Installation Aeration AdjustmentValve Description LOG Installation Diagram 1 Do not force logs downDiagram Optional Door GrillWiring Diagram Optional Remote ControlVerify proper operation after serv- icing Operating Instructions Maintenance Instructions Copy Lighting Plate InstructionsGas Control Valve Unit Body/FireboxMaintenance LOG Replacement CleaningGlass Replacement FAN MaintenanceThermodisc access is through the Fan Access Panel Valve MaintenanceTo remove fan Parts List Replacement / Spare Parts ListDescription Parts List Waterford E61 Gas Fireplace Insert Warranty ConditionsRegister your Waterford online at