Regency C34-NG2, C34-LP2 System Data, GAS Connection, High Elevation, GAS Pipe Pressure Testing

Page 24

INSTALLATION

SYSTEM DATA

(For 0 to 4,500 feet altitude)

Orifice Sizes:

 

 

Burner

Natural Gas

#36

Burner

Propane

#52

 

 

Max. Input Rating

 

Natural Gas

32,000 Btu/h

 

Propane

32,000 Btu/h

 

Min. Input Rating

 

Natural Gas

16,000 Btu/h

 

Propane

16,000 Btu/h

 

 

 

Supply Pressure

 

Natural Gas

min.

5.0" w.c

 

max.

8.0" w.c.

Propane

min.

12.0" w.c.

 

max.

13.0" w.c.

 

 

Manifold Pressure High

 

Natural Gas

3.8" +/- 0.2" w.c.

Propane

11" +/- 0.2" w.c.

Manifold Pressure Low

 

Natural Gas

1.1" +/- 0.2" w.c.

Propane

2.9" +/- 0.2" w.c.

Electrical: 120V, 1.13A, 60 Hz.

Circulation Fan:(optional) 2 speed 75/125 CFM. Log Set: Ceramic fiber, 4 per set.

Output capacity:

The efficiency rating of the appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.

GAS CONNECTION

The gas connection is a 3/8" NPT rigid pipe. This pipe is supplied separately and must be in- stalled at the left rear of the unit. See page 2 for diagram. The gas line can be rigid pipe or to make installation easier, use a listed flexible connector and manual shut-off valve if allowed by local codes, or copper if approved. For minimum and maximum supply pressure see the System Data table.

Note: During any pressure testing of the gas supply piping system that exceeds test pressures of 1/2 psig, this appliance and its individ- ual shut-off valve must be discon- nected from the piping system. If test pressures equal to or less than 1/2 psig are used then this appliance must be isolated from the piping system by closing its individual manual shut-off valve during the testing.

HIGH ELEVATION

This unit is approved in Canada for altitude 0 to 4500 ft. (CAN1 2.17-M90) with the orifice sup- plied.

GAS PIPE PRESSURE

TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pres- sures over 1/2 psig (14" w.c.).

The manifold pressure is controlled by a regu- lator built into the gas control, and should be checked at the pressure test point.

Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1)Make sure the valve is in the "OFF" position.

2)Loosen the "IN" (# 7) and/or "OUT" (# 6) pressure tap(s), turning counterclockwise with a 1/8" wide flat screwdriver.

3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.

4)Light the pilot and turn the valve to "ON" position.

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.

6)When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Screw should be snug, but do not over tighten.

Valve Description

1)Gas cock knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection

5)Main Operator

6)Outlet Pressure Tap

7)Inlet Pressure Tap

8)Pilot Outlet

9)Main Gas Outlet

10)Flange Securing Screw Holes

11)Alternative TC Connection Point

12)Thermoelectric Unit

13)Additional Valve Mounting Hole

24

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater

Image 24
Contents C34 Classic Direct Vent Freestanding Gas Stove Information for MOBILE/MANUFACTURED Homes After First Sale Classic Direct Vent Freestanding Gas Stove To the New OwnerTable of Contents Safety Label Installation SpecificationsGeneral Safety Information Save These InstructionsInstallation Checklist Locating Your Classic GAS StoveCombustion and Ventilation AIR Optional FAN Installation Disconnect power supply Before servicingPedestal Assembly LEG and Bottom Shield AssemblyFan Removal Installation Safety Precautions for the InstallerExterior Vent Terminal Locations Rigid Pipe Venting Components List 4DT-AJBRigid Pipe Venting Systems Alternate Horizontal Termination CapsVenting Arrangements Examples Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT OptionalOut a square that the cap can be mounted on Planning Your Dura-Vent Installation DURA-VENT Termination KITDURA-VENT Venting Components DescriptionDura-Vent Basic Horizontal Kit # DURA-VENT Horizontal Installations Below Grade InstallationSnorkel Terminations Vertical Termination Offset Chart Cathedral CeilingsRound Support RDS & Square Support SQS Support extensions Round Rdse or square Sqse GeneralConverting a Factory Built Metal Chimney Regency Classic C34-2 Direct Vent Freestanding Gas HeaterConverting a Masonry Chimney GAS Pipe Pressure Testing System DataGAS Connection High ElevationLOG Installation FrameOption 2 Remote Wall Switch Option 1 Remote Control InstallationOption 3 Wall Thermostat Installation Door HandleWiring Diagram Operating Instructions Aeration Adjustment Copy of the Lighting Plate InstructionsMaintenance Glass Replacement Installing Valve AssemblyRemoving Valve Assembly GOLD-PLATED DoorsParts List Main AssemblyBurner Assembly & LOG SET Base Options Warranty ConditionsInstaller Please complete the following information

C34-LP2, C34-NG2 specifications

The Regency C34-LP2 and C34-NG2 are two exceptional offerings in the world of gas fireplaces, designed to bring both warmth and style to modern living spaces. These units are perfect for homeowners who appreciate the ambiance of a traditional fireplace but desire the convenience and efficiency of gas heating.

Starting with the design, both the C34-LP2 and C34-NG2 feature a sleek and contemporary aesthetic, easily integrating into various interior styles. The clean lines and large viewing area provide an unobstructed view of the flames, creating a focal point in any room. The glass front complements the modern decor while emphasizing the natural flicker of firelight.

One of the standout features of the C34 series is the dual burner system, which allows for enhanced flame control and efficiency. The design offers an impressive flame pattern that can be adjusted to suit the user's preference, whether they seek a cozy, intimate setting or a more robust fire experience. This versatility is especially appealing for entertaining guests or creating a romantic atmosphere at home.

Technologically, both models are equipped with advanced features to optimize performance. The electronic ignition system ensures reliable lighting, while the precision flame adjustment allows users to easily manipulate heat levels. This adaptability can lead to significant energy savings, making the C34 series not only environmentally conscious but also cost-effective.

In terms of technical specifications, the C34-LP2 is designed for liquid propane, while the C34-NG2 runs on natural gas, providing flexibility depending on the homeowner's fuel availability. Both models possess impressive heating capabilities, with an output sufficient to warm larger spaces, making them ideal for living rooms, dining areas, or open-concept homes.

Safety is also a priority with the C34 series. Equipped with a safety shutoff system and a glass front that remains cool to the touch, these units are designed to provide peace of mind for families. The option for a remote control adds an additional layer of convenience, allowing users to adjust settings from across the room.

Overall, the Regency C34-LP2 and C34-NG2 unite modern innovation with traditional comfort. With their stunning design, advanced technology, and excellent heating efficiency, these gas fireplaces are a valuable addition to any home, enhancing both aesthetic and functional appeal.