Regency C34-NG2, C34-LP2 Installation Checklist, Locating Your Classic GAS Stove

Page 6

INSTALLATION

6)Never vent to another room or inside a building. Make sure that the vent is fitted as per the instructions starting on page 8.

7)Inspect the venting system annually for blockage and any signs of deterioration.

8)Venting terminals shall not be recessed into a wall or siding.

9)Any safety glass removed for servicing must be replaced prior to operating the appliance.

10)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)

Locate appliance, page 6, see Clearances

 

to Combustibles, page 6. Check Venting

 

Clearances, Vertical and Horizontal Termi-

 

nation requirements on pages 11 to 14.

2)

Install Optional Fan, page 7.

3)

Assemble stove base - pedestal or bottom

 

shield and legs, page 8.

4)

Install venting, either with the DV Stove

 

Horizontal Vent Kit (page 15) or the Dura-

 

Vent Termination kits (page 17). Check Vent

 

Restrictor setting, page 9. If converting a

 

Class-A Metal Chimney or Masonry Chim-

 

ney to a Direct Vent system, see instruc-

 

tions on pages 22 and 23.

5)

Make gas and electrical connections, page

 

24. Test the pilot. Must be as per diagram,

 

pages 28.

6)

Test gas pressure, page 24.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

3)Check for proper draft.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufac- turer.

LOCATING YOUR

CLASSIC

GAS STOVE

When selecting a location for your stove, en- sure that the clearances on this page are met as well as ensuring that there is adequate accessibility for servicing and proper opera- tion.

A)Cross Corner

B)Room Divider

C)Island

D)Flat on Wall

E)Flat on Wall Corner

F)Flush with Wall/Alcove

For Vent Termination requirements, see pages 10 to 11.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

CLEARANCES TO

COMBUSTIBLES

The clearances listed below are MINIMUM dis- tances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearanc- es do not coincide. For example, if the appliance is set as indicated in one of the diagrams but the back is too close, move the stove until the correct clearance to the back is obtained.

This unit can be installed on a solid combustible surface like a wood floor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with the unit) is installed.

This appliance may be installed only with the clearances as shown in the situations pictured. Do not combine clearances from one type of installation with another in order to achieve closer clearances.

Use the minimum clearances shown in the diagrams below:

 

C34 Clearance to Combustibles

A

Side Wall to Unit

10"/250mm

B

Back Wall to Unit

6"/ 150 mm

E

Side Wall to Unit

1.5"/ 38 mm

 

 

 

 

C34 Reference Dimensions

C

Back Wall to Flue Centerline

13"/330mm

D

Side Wall to Flue Centerline

22"/559mm

F

Side Wall to Flue Centerline

14"/356mm

7) Install log set, see page 25.

.

8)Install optional Wall Switch, Remote Control, or Wall Thermostat, page 26.

9)Final check, page 26.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to cus- tomer.

This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label) after burning appliance for 15 minutes.

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided. See page 7.

3)Appliance must be anchored to the floor. See page 8.

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer flue.

Extra provision for combustion air is not required.

Minimum ceiling height is 36" / 914 mm from top of unit.

Minimum clearance to vent 1-1/4" (32mm).

6

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater

Image 6
Contents C34 Classic Direct Vent Freestanding Gas Stove Information for MOBILE/MANUFACTURED Homes After First Sale Classic Direct Vent Freestanding Gas Stove To the New OwnerTable of Contents Safety Label General Safety Information InstallationSpecifications Save These InstructionsInstallation Checklist Locating Your Classic GAS StoveCombustion and Ventilation AIR Optional FAN Installation Disconnect power supply Before servicingPedestal Assembly LEG and Bottom Shield AssemblyFan Removal Installation Safety Precautions for the InstallerExterior Vent Terminal Locations Rigid Pipe Venting Components List 4DT-AJBRigid Pipe Venting Systems Alternate Horizontal Termination CapsVenting Arrangements Examples Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT OptionalOut a square that the cap can be mounted on DURA-VENT Venting Components Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DescriptionDura-Vent Basic Horizontal Kit # DURA-VENT Horizontal Installations Below Grade InstallationSnorkel Terminations Vertical Termination Offset Chart Cathedral CeilingsRound Support RDS & Square Support SQS Converting a Factory Built Metal Chimney Support extensions Round Rdse or square SqseGeneral Regency Classic C34-2 Direct Vent Freestanding Gas HeaterConverting a Masonry Chimney GAS Connection GAS Pipe Pressure TestingSystem Data High ElevationLOG Installation FrameOption 3 Wall Thermostat Installation Option 2 Remote Wall SwitchOption 1 Remote Control Installation Door HandleWiring Diagram Operating Instructions Aeration Adjustment Copy of the Lighting Plate InstructionsMaintenance Removing Valve Assembly Glass ReplacementInstalling Valve Assembly GOLD-PLATED DoorsParts List Main AssemblyBurner Assembly & LOG SET Base Options Warranty ConditionsInstaller Please complete the following information

C34-LP2, C34-NG2 specifications

The Regency C34-LP2 and C34-NG2 are two exceptional offerings in the world of gas fireplaces, designed to bring both warmth and style to modern living spaces. These units are perfect for homeowners who appreciate the ambiance of a traditional fireplace but desire the convenience and efficiency of gas heating.

Starting with the design, both the C34-LP2 and C34-NG2 feature a sleek and contemporary aesthetic, easily integrating into various interior styles. The clean lines and large viewing area provide an unobstructed view of the flames, creating a focal point in any room. The glass front complements the modern decor while emphasizing the natural flicker of firelight.

One of the standout features of the C34 series is the dual burner system, which allows for enhanced flame control and efficiency. The design offers an impressive flame pattern that can be adjusted to suit the user's preference, whether they seek a cozy, intimate setting or a more robust fire experience. This versatility is especially appealing for entertaining guests or creating a romantic atmosphere at home.

Technologically, both models are equipped with advanced features to optimize performance. The electronic ignition system ensures reliable lighting, while the precision flame adjustment allows users to easily manipulate heat levels. This adaptability can lead to significant energy savings, making the C34 series not only environmentally conscious but also cost-effective.

In terms of technical specifications, the C34-LP2 is designed for liquid propane, while the C34-NG2 runs on natural gas, providing flexibility depending on the homeowner's fuel availability. Both models possess impressive heating capabilities, with an output sufficient to warm larger spaces, making them ideal for living rooms, dining areas, or open-concept homes.

Safety is also a priority with the C34 series. Equipped with a safety shutoff system and a glass front that remains cool to the touch, these units are designed to provide peace of mind for families. The option for a remote control adds an additional layer of convenience, allowing users to adjust settings from across the room.

Overall, the Regency C34-LP2 and C34-NG2 unite modern innovation with traditional comfort. With their stunning design, advanced technology, and excellent heating efficiency, these gas fireplaces are a valuable addition to any home, enhancing both aesthetic and functional appeal.