Regency C34-NG2 Door Handle, Option 2 Remote Wall Switch, Option 1 Remote Control Installation

Page 26

INSTALLATION

DOOR HANDLE

Attach spring handle by rotating counter clock- wise onto rod. Ensure that the spring fits into the entire length of the rod.

CAUTION

Do not wire millivolt remote

control wires to the 120V AC wires

3)Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

CAUTION

Do not wire millivolt wall thermo- stat wires to the 120V AC wires

Note: Preferable if the thermostat is installed on an interior wall.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

DO NOT TRY TO TURN

DOOR HANDLE!

IT IS NOT DESIGNED

OPTION 2: REMOTE

WALL SWITCH

1)Run the wire through the opening in the rear of the unit. Be careful not to damage any wires.

Wire Size

Max. Length

 

14 GA.

50

Ft.

 

16 GA.

32

Ft.

 

18 GA.

20

Ft.

 

20 GA.

12

Ft.

 

22 GA.

9

Ft.

 

 

 

 

 

TO BE MOVED.

OPTION 1: REMOTE

CONTROL

INSTALLATION

Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver (protection from extreme heat is very important). Run wires from the fireplace to that location. Use the Thermostat Wire Table.

2)Connect the two wires to the gas valve. See diagram below.

Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run use the Thermostat Wire Table.

2)Connect the wire to the wall switch and install into receptacle box.

CAUTION

Do not wire millivolt wall switch for gas appliance to the 120V AC wires

OPTION 3: WALL

THERMOSTAT

INSTALLATION

Regency offers an optional programmable ther- mostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

Connect the wires as per the wiring diagram. Use the Thermostat Wire Table to determine the maximum wire length.

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label) at 15 minutes.

2)If required, adjusting the primary air to en- sure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION

Any alteration to the product that caus- es sooting or carboning that results in damage to the unit is not the re- sponsibility of the manufacturer and will not be covered by the warranty.

26

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater

Image 26
Contents C34 Classic Direct Vent Freestanding Gas Stove Information for MOBILE/MANUFACTURED Homes After First Sale Classic Direct Vent Freestanding Gas Stove To the New OwnerTable of Contents Safety Label General Safety Information InstallationSpecifications Save These InstructionsCombustion and Ventilation AIR Installation ChecklistLocating Your Classic GAS Stove Optional FAN Installation Disconnect power supply Before servicingFan Removal Pedestal AssemblyLEG and Bottom Shield Assembly Installation Safety Precautions for the InstallerExterior Vent Terminal Locations Rigid Pipe Venting Components List 4DT-AJBRigid Pipe Venting Systems Alternate Horizontal Termination CapsVenting Arrangements Examples Horizontal Venting with Two 2 90o Elbows Vertical Venting with Two 2 90o ElbowsDV Stove Horizontal Vent KIT OptionalOut a square that the cap can be mounted on DURA-VENT Venting Components Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DescriptionDura-Vent Basic Horizontal Kit # Snorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Installation Vertical Termination Round Support RDS & Square Support SQS Offset ChartCathedral Ceilings Converting a Factory Built Metal Chimney Support extensions Round Rdse or square SqseGeneral Regency Classic C34-2 Direct Vent Freestanding Gas HeaterConverting a Masonry Chimney GAS Connection GAS Pipe Pressure TestingSystem Data High ElevationLOG Installation FrameOption 3 Wall Thermostat Installation Option 2 Remote Wall SwitchOption 1 Remote Control Installation Door HandleWiring Diagram Operating Instructions Aeration Adjustment Copy of the Lighting Plate InstructionsMaintenance Removing Valve Assembly Glass ReplacementInstalling Valve Assembly GOLD-PLATED DoorsParts List Main AssemblyBurner Assembly & LOG SET Base Options Warranty ConditionsInstaller Please complete the following information

C34-LP2, C34-NG2 specifications

The Regency C34-LP2 and C34-NG2 are two exceptional offerings in the world of gas fireplaces, designed to bring both warmth and style to modern living spaces. These units are perfect for homeowners who appreciate the ambiance of a traditional fireplace but desire the convenience and efficiency of gas heating.

Starting with the design, both the C34-LP2 and C34-NG2 feature a sleek and contemporary aesthetic, easily integrating into various interior styles. The clean lines and large viewing area provide an unobstructed view of the flames, creating a focal point in any room. The glass front complements the modern decor while emphasizing the natural flicker of firelight.

One of the standout features of the C34 series is the dual burner system, which allows for enhanced flame control and efficiency. The design offers an impressive flame pattern that can be adjusted to suit the user's preference, whether they seek a cozy, intimate setting or a more robust fire experience. This versatility is especially appealing for entertaining guests or creating a romantic atmosphere at home.

Technologically, both models are equipped with advanced features to optimize performance. The electronic ignition system ensures reliable lighting, while the precision flame adjustment allows users to easily manipulate heat levels. This adaptability can lead to significant energy savings, making the C34 series not only environmentally conscious but also cost-effective.

In terms of technical specifications, the C34-LP2 is designed for liquid propane, while the C34-NG2 runs on natural gas, providing flexibility depending on the homeowner's fuel availability. Both models possess impressive heating capabilities, with an output sufficient to warm larger spaces, making them ideal for living rooms, dining areas, or open-concept homes.

Safety is also a priority with the C34 series. Equipped with a safety shutoff system and a glass front that remains cool to the touch, these units are designed to provide peace of mind for families. The option for a remote control adds an additional layer of convenience, allowing users to adjust settings from across the room.

Overall, the Regency C34-LP2 and C34-NG2 unite modern innovation with traditional comfort. With their stunning design, advanced technology, and excellent heating efficiency, these gas fireplaces are a valuable addition to any home, enhancing both aesthetic and functional appeal.