Regency C34-LP2, C34-NG2 installation manual Table of Contents

Page 3

TABLE OF CONTENTS

 

Page

Safety Label

 

Safety Label

4

Installation

 

Specifications

5

Before You Start

5

General Safety Information

5

Installation Checklist

6

Locating Your Classic Gas Stove

6

Manufactured Mobile Home Requirements

6

Combustion and Ventilation Air

6

Clearances to Combustibles

6

Optional Fan Installation

7

Pedestal Assembly

8

Leg and Bottom Shield Assembly

8

Venting

9

Installation Precautions

9

Safety Precautions for the Installer

9

Vent Restrictor Position

9

Exterior Vent Terminal Locations

10

Rigid Pipe Venting Components List

11

Rigid Pipe Venting Systems

 

Horizontal and Vertical Terminations

12

Venting Arrangements

 

Horizontal Terminations (all Systems)

13

Vertical Terminations (Dura-Vent)

13

Horizontal and Vertical Venting With Two Elbows

14

DV Stove Horizontal Vent Kit 945-216

15

DV Stove Horizontal Vent Kit 945-216 Installation

15

Dura-Vent Termination Systems

17

Planning Your Dura-Vent Installation

17

Dura-Vent Venting Components

17

Dura-Vent Horizontal Installations

19

Dura-Vent Vertical Termination

20

Offset Chart

21

Cathedral Ceiling Installations

21

Converting a Class-A Metal Chimney or Masonry

 

Chimney to a Direct Vent System

22

- Instructions for Converting a Factory Built

 

Metal Chimney

22

- Instructions for Converting a Masonry Chimney ..

23

System Data Table

24

 

Page

Gas Connection

24

High Elevation

24

Gas Pressure Test

24

Valve Description

24

Log Set Installation

25

Door and Glass Frame

25

Door Handle

26

Optional Remote Control Installation

26

Remote Wall Switch

26

Optional Wall Thermostat

26

Thermostat Wire Table

26

Final Check

26

Wiring Diagram

27

Operating Instructions

 

Operating Instructions

28

Lighting Procedure

28

Shutdown Procedure

28

First Fire

28

Pilot Adjustment

28

Aeration Adjustment

29

Copy of Lighting Plate Instructions

29

Normal Operating Sounds of Gas Appliances

30

Thermopile/Thermocouple

30

Maintenance

 

Maintenance Instructions

30

General Vent Maintenance

30

Log Replacement

30

Gold Plated Doors

31

Glass Gasket

31

Glass Replacement

31

Removing Valve Assembly

31

Installing Valve Assembly

31

Parts List

 

Replacement/Spare Parts list

32

Warranty

 

Warranty

35

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater

3

Image 3
Contents C34 Classic Direct Vent Freestanding Gas Stove Classic Direct Vent Freestanding Gas Stove To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Save These Instructions InstallationSpecifications General Safety InformationInstallation Checklist Locating Your Classic GAS StoveCombustion and Ventilation AIR Disconnect power supply Before servicing Optional FAN InstallationPedestal Assembly LEG and Bottom Shield AssemblyFan Removal Safety Precautions for the Installer InstallationExterior Vent Terminal Locations 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsVenting Arrangements Examples Vertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsOptional DV Stove Horizontal Vent KITOut a square that the cap can be mounted on Description Planning Your Dura-Vent InstallationDURA-VENT Termination KIT DURA-VENT Venting ComponentsDura-Vent Basic Horizontal Kit # DURA-VENT Horizontal Installations Below Grade InstallationSnorkel Terminations Vertical Termination Offset Chart Cathedral CeilingsRound Support RDS & Square Support SQS Regency Classic C34-2 Direct Vent Freestanding Gas Heater Support extensions Round Rdse or square SqseGeneral Converting a Factory Built Metal ChimneyConverting a Masonry Chimney High Elevation GAS Pipe Pressure TestingSystem Data GAS ConnectionFrame LOG InstallationDoor Handle Option 2 Remote Wall SwitchOption 1 Remote Control Installation Option 3 Wall Thermostat InstallationWiring Diagram Operating Instructions Copy of the Lighting Plate Instructions Aeration AdjustmentMaintenance GOLD-PLATED Doors Glass ReplacementInstalling Valve Assembly Removing Valve AssemblyMain Assembly Parts ListBurner Assembly & LOG SET Base Options Conditions WarrantyInstaller Please complete the following information

C34-LP2, C34-NG2 specifications

The Regency C34-LP2 and C34-NG2 are two exceptional offerings in the world of gas fireplaces, designed to bring both warmth and style to modern living spaces. These units are perfect for homeowners who appreciate the ambiance of a traditional fireplace but desire the convenience and efficiency of gas heating.

Starting with the design, both the C34-LP2 and C34-NG2 feature a sleek and contemporary aesthetic, easily integrating into various interior styles. The clean lines and large viewing area provide an unobstructed view of the flames, creating a focal point in any room. The glass front complements the modern decor while emphasizing the natural flicker of firelight.

One of the standout features of the C34 series is the dual burner system, which allows for enhanced flame control and efficiency. The design offers an impressive flame pattern that can be adjusted to suit the user's preference, whether they seek a cozy, intimate setting or a more robust fire experience. This versatility is especially appealing for entertaining guests or creating a romantic atmosphere at home.

Technologically, both models are equipped with advanced features to optimize performance. The electronic ignition system ensures reliable lighting, while the precision flame adjustment allows users to easily manipulate heat levels. This adaptability can lead to significant energy savings, making the C34 series not only environmentally conscious but also cost-effective.

In terms of technical specifications, the C34-LP2 is designed for liquid propane, while the C34-NG2 runs on natural gas, providing flexibility depending on the homeowner's fuel availability. Both models possess impressive heating capabilities, with an output sufficient to warm larger spaces, making them ideal for living rooms, dining areas, or open-concept homes.

Safety is also a priority with the C34 series. Equipped with a safety shutoff system and a glass front that remains cool to the touch, these units are designed to provide peace of mind for families. The option for a remote control adds an additional layer of convenience, allowing users to adjust settings from across the room.

Overall, the Regency C34-LP2 and C34-NG2 unite modern innovation with traditional comfort. With their stunning design, advanced technology, and excellent heating efficiency, these gas fireplaces are a valuable addition to any home, enhancing both aesthetic and functional appeal.