Regency C34-LP2, C34-NG2 installation manual Installation, Safety Precautions for the Installer

Page 9

 

 

INSTALLATION

VENTING

INSTALLATION

VENT RESTRICTOR

INTRODUCTION

PRECAUTIONS

POSITION

The DV Stove Horizontal Vent Kit and the Simpson Dura-Vent Direct Vent System Model DV-GS venting systems, in combination with the Classic Direct Vent Freestanding Gas Stove, C34B-NG/C34G-NG and C34B-LP/C34G-LP, have been tested and listed as direct vent heater systems by Warnock Hersey.

If converting a Class-A Metal Chimney or Ma- sonry Chimney to a Direct Vent system, see instructions on pages 22 and 23.

The C34 uses the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be con- nected to any other appliance.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent sys- tems are prohibited.

IMPORTANT

Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fire or other safety hazard, and will void the warranty. Be sure to check the venting and clearance to combustible require- ments. Consult your local building codes before beginning installation.

The location of the termination cap must con- form to the requirements in the Exterior Vent Terminal Locations diagram on page 10.

These venting systems are engineered prod- ucts that have been designed and tested for use with the C34B-NG/C34G-NG and the C34B- LP/C34G-LP. The warranty will be voided and serious fire, health or other safety hazards may result from any of the following actions:

1)Installation of any damaged Direct Vent component

2)UnauthorizedmodificationoftheDirectVent System

3)Installation of any component part not man- ufactured or approved by Simpson Dura- Vent or Fireplace Products International Ltd.

4)Installation other than as instructed by Simp- son Dura-Vent and Fireplace Products In- ternational Ltd.

Warning: Always maintain required clearances (air spaces) to nearby com- bustibles to prevent a fire hazard. Do not fill air spaces with insulation.

Be sure to check the vent termination clearance requirements from decks, windows, soffits, gas regulators, air supply inlets and public walkways as specified in the Exterior Vent Terminal Locations on page 10 and in your local building codes.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chim- ney serving a separate solid fuel or gas- burning appliance. Each direct vent gas

appliance must use it's own separate vent system. Common vent systems are prohibited.

SAFETY

PRECAUTIONS FOR THE INSTALLER

1)Wear gloves and safety glasses for pro- tection.

2)Exercise extreme caution when using lad- ders or on roof tops.

3)Be aware of electrical wiring locations in walls and ceilings.

Vent restriction is required for certain venting installations, see the diagrams on page 13 to determine if they are required for your instal- lation.

The vent restrictor has three settings: "C" Center (factory setting), "L" Left, and "R" Right. Simply loosen the screws and push the vent restrictor plate to the correct position. Tighten the screws.

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater

9

Image 9
Contents C34 Classic Direct Vent Freestanding Gas Stove Classic Direct Vent Freestanding Gas Stove To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Specifications InstallationGeneral Safety Information Save These InstructionsInstallation Checklist Locating Your Classic GAS StoveCombustion and Ventilation AIR Disconnect power supply Before servicing Optional FAN InstallationPedestal Assembly LEG and Bottom Shield AssemblyFan Removal Safety Precautions for the Installer InstallationExterior Vent Terminal Locations 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsVenting Arrangements Examples Vertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsOptional DV Stove Horizontal Vent KITOut a square that the cap can be mounted on DURA-VENT Termination KIT Planning Your Dura-Vent InstallationDURA-VENT Venting Components DescriptionDura-Vent Basic Horizontal Kit # DURA-VENT Horizontal Installations Below Grade InstallationSnorkel Terminations Vertical Termination Offset Chart Cathedral CeilingsRound Support RDS & Square Support SQS General Support extensions Round Rdse or square SqseConverting a Factory Built Metal Chimney Regency Classic C34-2 Direct Vent Freestanding Gas HeaterConverting a Masonry Chimney System Data GAS Pipe Pressure TestingGAS Connection High ElevationFrame LOG InstallationOption 1 Remote Control Installation Option 2 Remote Wall SwitchOption 3 Wall Thermostat Installation Door HandleWiring Diagram Operating Instructions Copy of the Lighting Plate Instructions Aeration AdjustmentMaintenance Installing Valve Assembly Glass ReplacementRemoving Valve Assembly GOLD-PLATED DoorsMain Assembly Parts ListBurner Assembly & LOG SET Base Options Conditions WarrantyInstaller Please complete the following information

C34-LP2, C34-NG2 specifications

The Regency C34-LP2 and C34-NG2 are two exceptional offerings in the world of gas fireplaces, designed to bring both warmth and style to modern living spaces. These units are perfect for homeowners who appreciate the ambiance of a traditional fireplace but desire the convenience and efficiency of gas heating.

Starting with the design, both the C34-LP2 and C34-NG2 feature a sleek and contemporary aesthetic, easily integrating into various interior styles. The clean lines and large viewing area provide an unobstructed view of the flames, creating a focal point in any room. The glass front complements the modern decor while emphasizing the natural flicker of firelight.

One of the standout features of the C34 series is the dual burner system, which allows for enhanced flame control and efficiency. The design offers an impressive flame pattern that can be adjusted to suit the user's preference, whether they seek a cozy, intimate setting or a more robust fire experience. This versatility is especially appealing for entertaining guests or creating a romantic atmosphere at home.

Technologically, both models are equipped with advanced features to optimize performance. The electronic ignition system ensures reliable lighting, while the precision flame adjustment allows users to easily manipulate heat levels. This adaptability can lead to significant energy savings, making the C34 series not only environmentally conscious but also cost-effective.

In terms of technical specifications, the C34-LP2 is designed for liquid propane, while the C34-NG2 runs on natural gas, providing flexibility depending on the homeowner's fuel availability. Both models possess impressive heating capabilities, with an output sufficient to warm larger spaces, making them ideal for living rooms, dining areas, or open-concept homes.

Safety is also a priority with the C34 series. Equipped with a safety shutoff system and a glass front that remains cool to the touch, these units are designed to provide peace of mind for families. The option for a remote control adds an additional layer of convenience, allowing users to adjust settings from across the room.