Regency C34-LP2, C34-NG2 Installation, Save These Instructions, Specifications, Before YOU Start

Page 5

INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The CLASSIC Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the in- structions in this manual first. Consult the building authority having jurisdiction to deter- mine the need for a permit prior to starting the installation.

- WARNING -

Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

Note: These instructions take prece- dence over Simpson Dura-Vent instructions

SPECIFICATIONS

Fuels: C34-NG is approved for use with natural gas. C34-LP is approved for use with liquefied petroleum gases (propane).

Electrical: 120V. A.C. system.

Optional circulation fan: Two speed, 125/

75 CFM.

Log Sets: Ceramic fibre, 4 per set.

Vent System: Coaxial (6 5/8" outer/ 4" inner liner) rigid flue and termination cap.

SHOULD OVERHEATING OCCUR, OR THE GAS SUPPLY FAIL TO SHUT OFF, SHUT OFF THE MANU- AL GAS VALVE TO THE APPLI- ANCE BEFORE SHUTTING OFF THE ELECTRICAL SUPPLY.

- WARNING -

Risk of fire or electric shock. Only qualified service personnel shall be used to install and provide main- tenance of this appliance.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

THIS APPLIANCE SHOULD BE IN- STALLED, REPAIRED, INSPECT- ED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERV- ICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CAR- PETING, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPART- MENT, BURNER AND CIRCULAT- ING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LO- CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY MAY CAUSE A SERIOUS HOUSE FIRE AND WILL VOID YOUR WAR- RANTY.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE.

1)Provide adequate clearances for servic- ing, proper operation and around the air openings into the combustion chamber.

2)The appliance may be installed on a flat, solid, continuous surface (e.g. wood, met- al, concrete). This may be the floor, or it can

be raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, see clearances to combustibles on page 6.

The CLASSIC Direct Vent Freestanding Gas Stove can be installed in a wide variety of ways and will fit nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner. This appliance is Listed for Alcove installations, maintain minimum Alcove clear- ances as follows, minimum ceiling height of 65-11/16", minimum width of 48" and a maximum depth of 36".

3)TheCLASSICDirectVentFreestandingGas Stove is approved for alcove installations, which meet the clearances listed on page6. This unit can be installed in a bedroom, when installed with a millivolt thermostat. This unit is approved for manufactured home instal- lations, see page 13 for the required vent arrangements. If installed into a manufac- tured or mobile home the unit must be bolted down to the floor.

4)We recommend that you plan your installa- tion on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have a qualified building inspector review your plans before installation.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or Na- tional Electrical Codes,CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Cana- dian Electrical Code.

3)The appliance should be inspected for shipping damage before use and serviced annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bed- ding material, etc. It is imperative that control compartments, and circulating air passage- ways of the appliance be kept clean.

4)See general construction and assembly instructions. The appliance and vent should be enclosed when installed in or passing through a living area.

5)This appliance must be connected to the specified vent and termination cap to the outside of the building envelope.

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater

5

Image 5
Contents C34 Classic Direct Vent Freestanding Gas Stove Classic Direct Vent Freestanding Gas Stove To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Specifications InstallationGeneral Safety Information Save These InstructionsCombustion and Ventilation AIR Installation ChecklistLocating Your Classic GAS Stove Disconnect power supply Before servicing Optional FAN InstallationFan Removal Pedestal AssemblyLEG and Bottom Shield Assembly Safety Precautions for the Installer InstallationExterior Vent Terminal Locations 4DT-AJB Rigid Pipe Venting Components ListAlternate Horizontal Termination Caps Rigid Pipe Venting SystemsVenting Arrangements Examples Vertical Venting with Two 2 90o Elbows Horizontal Venting with Two 2 90o ElbowsOptional DV Stove Horizontal Vent KITOut a square that the cap can be mounted on DURA-VENT Termination KIT Planning Your Dura-Vent InstallationDURA-VENT Venting Components DescriptionDura-Vent Basic Horizontal Kit # Snorkel Terminations DURA-VENT Horizontal InstallationsBelow Grade Installation Vertical Termination Round Support RDS & Square Support SQS Offset ChartCathedral Ceilings General Support extensions Round Rdse or square SqseConverting a Factory Built Metal Chimney Regency Classic C34-2 Direct Vent Freestanding Gas HeaterConverting a Masonry Chimney System Data GAS Pipe Pressure TestingGAS Connection High ElevationFrame LOG InstallationOption 1 Remote Control Installation Option 2 Remote Wall SwitchOption 3 Wall Thermostat Installation Door HandleWiring Diagram Operating Instructions Copy of the Lighting Plate Instructions Aeration AdjustmentMaintenance Installing Valve Assembly Glass ReplacementRemoving Valve Assembly GOLD-PLATED DoorsMain Assembly Parts ListBurner Assembly & LOG SET Base Options Conditions WarrantyInstaller Please complete the following information

C34-LP2, C34-NG2 specifications

The Regency C34-LP2 and C34-NG2 are two exceptional offerings in the world of gas fireplaces, designed to bring both warmth and style to modern living spaces. These units are perfect for homeowners who appreciate the ambiance of a traditional fireplace but desire the convenience and efficiency of gas heating.

Starting with the design, both the C34-LP2 and C34-NG2 feature a sleek and contemporary aesthetic, easily integrating into various interior styles. The clean lines and large viewing area provide an unobstructed view of the flames, creating a focal point in any room. The glass front complements the modern decor while emphasizing the natural flicker of firelight.

One of the standout features of the C34 series is the dual burner system, which allows for enhanced flame control and efficiency. The design offers an impressive flame pattern that can be adjusted to suit the user's preference, whether they seek a cozy, intimate setting or a more robust fire experience. This versatility is especially appealing for entertaining guests or creating a romantic atmosphere at home.

Technologically, both models are equipped with advanced features to optimize performance. The electronic ignition system ensures reliable lighting, while the precision flame adjustment allows users to easily manipulate heat levels. This adaptability can lead to significant energy savings, making the C34 series not only environmentally conscious but also cost-effective.

In terms of technical specifications, the C34-LP2 is designed for liquid propane, while the C34-NG2 runs on natural gas, providing flexibility depending on the homeowner's fuel availability. Both models possess impressive heating capabilities, with an output sufficient to warm larger spaces, making them ideal for living rooms, dining areas, or open-concept homes.

Safety is also a priority with the C34 series. Equipped with a safety shutoff system and a glass front that remains cool to the touch, these units are designed to provide peace of mind for families. The option for a remote control adds an additional layer of convenience, allowing users to adjust settings from across the room.

Overall, the Regency C34-LP2 and C34-NG2 unite modern innovation with traditional comfort. With their stunning design, advanced technology, and excellent heating efficiency, these gas fireplaces are a valuable addition to any home, enhancing both aesthetic and functional appeal.