Regency C33-LP3 Installation, Before YOU Start, Important Message, General Safety Information

Page 6

INSTALLATION

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALI- FIED SERVICE PERSON. THE APPLIANCE SHOULD BE IN- SPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PRO- FESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EX- CESSIVELINTFROMCARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PAS- SAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY MAY CAUSE A SERIOUS HOUSE FIRE AND WILL VOID YOUR WAR- RANTY.

CHILDRENANDADULTSSHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISEDWHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAM- MABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

IMPORTANT MESSAGE

The CLASSIC Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

4)This appliance is Listed for Alcove instal- lations, maintain minimum Alcove clear- ances as follows, minimum ceiling height of 65-11/16", minimum width of 48" and a maximum depth of 36".

5)This unit is not approved for installation into a mobile home.

6)See general construction and assembly instructions.

7)This appliance must be connected to a vent and terminate to the outside of the building envelope. Never vent to another room or inside a building.

8)Inspect the venting system annually for blockage and any signs of deterioration.

9)Any safety glass removed for servicing must be replaced prior to operating the ap- pliance.

10)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

11)Wear gloves and safety glasses for protec- tion while doing required maintenance.

12)Under no circumstances should this ap- pliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

13)Installation and any repairs to this appliance should be done by a qualifi ed service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

14)Do not strike the glass door.

15)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

16)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

Emissions from burning wood or gas could contain chemicals known to the State of Cali- fornia to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)Locate appliance. Refer to the "Clearance to Combustible" section.

2)Install Optional Fan. Refer to the "Optional Fan Installation" section.

3)Assemble stove base - pedestal or legs. Refer to "Pedestal Assembly" or "Leg and Bottom Shield Assembly" section.

4)If using outside air. Refer to the "Optional Outside Air" section.

5)Install venting. Refer to the "Venting" section.

6)Make gas and electrical connections. Refer to the "Gas Connection" section.

Test the pilot. Must be as per diagram in the "Pilot Adjustment" section.

7)Test gas pressure. Refer to the "Gas Pipe Pres- sure Testing" section.

8)Test for fl ue spillage. Refer to the "Test for Fuel Spillage" section.

9)Install standard and optional features. Refer to the following sections where applicable:

a.Log Set Installation

b.Remote Control

c.Remote Wall Switch

d.Wall Thermostat

11)Final check. Refer to the "Final Check" sec- tion.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring cor- rectly and operation fully explained to customer.

6

Regency® CLASSIC C33-3 Freestanding Gas Stove

Image 6
Contents C33 Classic Freestanding Gas Stove To the New Owner Table of Contents Safety Label Requirements MA Code CO DetectorInstallation Checklist InstallationGeneral Safety Information Before YOU StartClearances to Combustibles Optional FAN InstallationC33-3 Reference Dimensions This includesPedestal Assembly WiringOptional Outside AIR Draft HoodVenting System Data GAS Pipe Pressure TestingGAS Connection High ElevationWith Pedestal Installation DC SparkerValve With Bottom ShieldTest for LOG SET Flue Spillage Installation OperationRemote Wall Switch Safety LatchRemote Control Installation Wall Thermostat InstallationWiring Diagrams Normal Operating Sounds of GAS Appliances Shutdown Procedure Do Not Attempt To Clean The Glass While It is still hotOperating Instructions For Your Safety Read Before Lighting Copy of the Lighting Plate InstructionsAeration Adjustment MaintenanceGeneral Vent Maintenance Pilot AdjustmentClean any fingerprints off before turning the unit on LOG ReplacementGlass Replacement GOLD-PLATED DoorsRemoving Valve Assembly InstallingTo remove valve from valve assembly, continue Parts List Main AssemblyBurner & Logs Base Options Regency Classic C33-3 Freestanding Gas Stove Regency Classic C33-3 Freestanding Gas Stove Regency Classic C33-3 Freestanding Gas Stove Warranty ConditionsInstaller Please complete the following information

C33-NG3, C33-LP3 specifications

The Regency C33-NG3 and C33-LP3 are advanced gas fireplaces that reflect both elegance and functionality, making them ideal choices for those looking to enhance their living spaces. These models stand out in the market due to their exceptional design and innovative technology, catering to both natural gas and propane options.

One of the main features of the Regency C33-NG3 and C33-LP3 is their impressive heating capacity. Both models boast an efficiency rating that competently warms your space while maintaining eco-friendly operations. This makes them an attractive option for homeowners seeking a blend of luxury and sustainable heating solutions.

Both fireplace models are designed with a modern aesthetic, featuring a sleek front and expansive viewing area that allows the warm glow of flames to be the centerpiece of any room. With customizable trim options and the ability to add decorative media such as stones or glass, these fireplaces can be tailored to fit various interior designs. The contemporary linear design not only offers visual appeal but also maximizes the heat output, ensuring a cozy environment.

In terms of technology, the Regency C33-NG3 and C33-LP3 come equipped with an advanced electronic ignition system. This feature allows for easy lighting of the fireplace with the push of a button, eliminating the hassle associated with traditional ignition methods. Additionally, these models include a thermostatic control option, enabling users to maintain their desired temperature effortlessly.

The patented heat exchanger technology enhances the overall efficiency of both models, ensuring that the heat produced is directed into the room rather than being lost through the venting system. This innovative design contributes to a more efficient heating experience, making these fireplaces a cost-effective choice for consumers.

Safety is also a priority with the Regency C33-NG3 and C33-LP3. Both models incorporate safety barriers and advanced flame sensing technology, ensuring peace of mind during operation. The sleek glass front not only adds to the aesthetic but also keeps flames safely contained, making them suitable for families with children or pets.

In conclusion, the Regency C33-NG3 and C33-LP3 combine modern elegance with advanced heating technology. Their efficient heating capabilities, customizable designs, and user-friendly features make them standout choices for anyone looking to elevate their home’s ambiance while ensuring warmth and comfort.