SAFETY LABEL

This is a copy of the label that accompanies each Regency Small Freestanding Woodstove (F1100S). It is located in the upper right corner

of the back of the stove. We have printed a copy of the contents here for your review.

NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO

DO NOT REMOVE THIS LABEL

SUITABLE FOR MOBILE HOME INSTALLATION

100

MODEL: REGENCY SMALL FREESTANDING STOVE - F1100S

TESTED TO: CSA B366.2 / ULC S627 / UL 1482 REPORT NO.6621 (MAY 1993)

 

 

 

 

 

 

 

 

 

 

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS

 

 

 

 

 

 

 

 

 

 

AND INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG

 

 

 

 

 

 

 

 

 

 

BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED FACTORY-BUILT CHIMNEY SUITABLE FOR

 

 

 

 

 

 

 

 

 

 

USE WITH SOLID FUELS OR MASONRY CHIMNEY.

 

 

 

 

 

 

 

 

 

 

 

 

SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED

 

 

 

 

 

 

 

 

 

 

F1100S WITH

F1100S WITHOUT

FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY

CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A

AIRMATE SHIELD

AIRMATE SHIELD

CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

BACKWALL

 

 

 

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

 

 

 

 

SIDEWALL

B

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F1100S WITH AIRMATE SHIELD

 

F1100S WITHOUT AIRMATE SHIELD

 

 

 

A

 

 

 

 

MEASURE

 

 

 

 

FLUE

 

MEASURE

 

 

 

FLUE

 

 

 

D

 

 

 

 

FROM

HEATER

 

CENTER-LINE

FROM

HEATER

 

CENTER-LINE

 

 

 

 

 

 

RESIDENTIAL INSTALLATION USING

 

RESIDENTIAL INSTALLATION USING

 

 

 

BACKWALL

 

 

 

 

SINGLE WALL CONNECTOR

 

 

SINGLE WALL CONNECTOR

 

 

SIDEWALL

 

SIDEWALL

 

SIDEWALL

A 330 mm / 13 in

D 635 mm / 25

in

SIDEWALL

A 380 mm /15

in

D 685

mm / 27

in

 

G

G

 

 

 

 

H

J

 

 

 

BACKWALL

B 280 mm / 11 in

E 445 mm / 17.5in

BACKWALL

B 265 mm / 10.5in

E 430

mm / 17

in

 

 

 

 

 

 

 

CORNER

C 205 mm / 8

in

F 510 mm / 20

in

CORNER

C 280 mm / 11

in

F 585

mm / 23

in

 

 

 

 

 

 

 

INSTALLATION USING LISTED DOUBLE WALL

INSTALLATION USING LISTED DOUBLE WALL

 

 

 

 

 

 

 

 

 

CONNECTOR - MOBILE HOME

 

CONNECTOR - MOBILE HOME

 

 

 

I

 

 

 

 

SIDEWALL

A 280 mm / 11 in

D 585

mm / 23

in

SIDEWALL

A 330 mm / 13 in

D 635

mm / 25 in

 

 

 

 

 

 

 

 

 

 

 

 

 

BACKWALL

B 150 mm / 6

in

E 320

mm / 12.5in

BACKWALL

B 125 mm / 5

in

E 290

mm / 11.5in

 

 

ADJACENT WALL

 

 

CORNER

C 150 mm / 6

in

F 460

mm / 18

in

CORNER

C 230 mm / 9

in

F 535

mm / 21

in

 

 

 

 

 

SIDEWALL

F

 

 

 

 

SIDEWALL

A 230 mm / 9

in

D 535

mm / 21

in

SIDEWALL

A 345 mm / 13.5in

D 650

mm / 25.5in

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION USING LISTED DOUBLE WALL

 

 

C

 

 

 

 

INSTALLATION USING LISTED DOUBLE WALL

 

 

 

 

 

 

 

 

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

 

 

 

 

 

 

 

BACKWALL

B 125 mm / 5

in

E 290

mm / 11.5in

BACKWALL

B 125 mm / 5

in

E 290

mm / 11.5in

 

 

 

 

 

 

 

CORNER

C 75

mm / 3

in

F 380

mm / 15

in

CORNER

C 125 mm / 5

in

F 430

mm / 17

in

 

 

 

 

BACK M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLOOR

 

INSTALLATION USING LISTED DOUBLE WALL

INSTALLATION USING LISTED DOUBLE WALL

 

 

 

 

 

 

L

 

 

PROTECTION*

 

 

 

 

CONNECTOR - ALCOVE

 

 

 

CONNECTOR - ALCOVE

 

 

 

 

SIDE

 

SIDE

SIDEWALL

mm / 23

in

SIDEWALL

mm / 25

in

K 405 mm / 16 in

 

G 280 mm / 11 in

I 585

G 330 mm / 13 in

I 635

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BACKWALL

H 180 mm / 7

in

J 345

mm / 13.5in

BACKWALL

H 125 mm / 5

in

J 290

mm / 11.5in

L 150 mm / 6 in

 

 

 

M

150 mm / 6 in

 

K

FRONT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT

MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.

* In Canada, floor protection must

MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"

extend 18" to the front and 8" to

each side of the stove.

THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.

FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.

OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS

COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR

IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM: SECURITY MODEL S2100, ICC EXCEL 2100 .

IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL- FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.

 

MANUFACTURED BY: FIREPLACE PRODUCTS INTERNATIONAL LTD.

 

6988 VENTURE ST.

 

DELTA, BC V4G 1H4

 

MADE IN CANADA

 

 

UNITED STATES ENVIRONMENTAL

CERTIFIED TO COMPLY WITH JULY 1990,

PROTECTION AGENCY

PARTICULATE EMISSION STANDARDS.

CAUTION

HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,

 

 

 

 

 

 

 

CLOTHING AND FURNITUREAWAY. CONTACT MAY CAUSE

 

 

 

 

 

 

 

 

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

WD

908-281

 

01/03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC

MANUFACTURE

2002

 

2003

DATE OF

2001

4

Regency Freestanding Woodstove

Image 4
Contents Freestanding Woodstoves Regencyfireplaceproduct Modular PartsTable of Contents 2002 Safety Label2001 101 APR MAY JUN JUL AUG Sept102 Model Regency Large Freestanding Stove F3100L Tested toDo not Remove this Label DEC NOVSept MARSafety Label Installation Residential InstallationModular Installation Options Room AIRResidential Installation C Vent Single Wall Minimum Clearance to Combustible MaterialsMinimum Alcove Clearance to Combustible Materials Floor ProtectionStove Assembly Prior to Installation Airmate Assembly for F1100 F2100, and F3100S2100M & S3100L Side Shield Adjustment Small & Medium 850-105 Large 850-305Step by Step Chimney Connector Installation Leg and Bottom Shield AssemblyMobile Home Installation Recommended Heights for Woodstove FlueListed Components For Mobile Home Installation Brick Flue Baffle & Secondary AIR Tube InstallationInstallation Canadian InstallationsMedium Stoves F2100M and S2100M Small Stoves F1100SBrick Installation Door Handle Glass InstallationOptional Accessories Pedestal Ash Drawer KitBlower/Fan Wiring Diagram Operating Instructions Operating InstructionsDraft Control First FireSafety Guidelines MaintenanceSafety Precautions ASH DisposalMaintenance Creosote Latch Adjustment Glass MaintenanceMaintenance GOLD-PLATED Doors Door GasketF1100 & F3100 Stove Main Assembly Parts ListDescription F2100 Stove Main Assembly S2100 & S3100 Step Stove Main Assembly PEDESTAL, Bottom Shield & LEG Options Firebrick Warranty Warranty LifetimeInstaller Please complete the following information