This is a copy of the label that accompanies each Regency Small Freestanding Woodstove (F1100S). It is located in the upper right corner
of the back of the stove. We have printed a copy of the contents here for your review.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO | DO NOT REMOVE THIS LABEL |
SUITABLE FOR MOBILE HOME INSTALLATION | 100 |
MODEL: REGENCY SMALL FREESTANDING STOVE - F1100S |
TESTED TO: CSA B366.2 / ULC S627 / UL 1482 REPORT NO.6621 (MAY 1993)
|
|
|
|
|
|
|
|
|
| INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND | |||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS | |||
|
|
|
|
|
|
|
|
|
| AND INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG | |||
|
|
|
|
|
|
|
|
|
| BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED | |||
|
|
|
|
|
|
|
|
|
| USE WITH SOLID FUELS OR MASONRY CHIMNEY. |
|
| |
|
|
|
|
|
|
|
|
|
| SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED | |||
|
|
|
|
|
|
|
|
|
| ||||
F1100S WITH | F1100S WITHOUT | FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY | |||||||||||
CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A | |||||||||||||
AIRMATE SHIELD | AIRMATE SHIELD | ||||||||||||
CHIMNEY FLUE SERVING ANOTHER APPLIANCE. | BACKWALL |
|
|
| MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS |
|
|
|
| SIDEWALL | B | E |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
F1100S WITH AIRMATE SHIELD |
| F1100S WITHOUT AIRMATE SHIELD |
|
|
| A |
|
|
|
| |||||||||
MEASURE |
|
|
|
| FLUE |
| MEASURE |
|
|
| FLUE |
|
|
| D |
|
|
|
|
FROM | HEATER |
| FROM | HEATER |
|
|
|
|
|
|
| ||||||||
RESIDENTIAL INSTALLATION USING |
| RESIDENTIAL INSTALLATION USING |
|
|
| BACKWALL |
|
|
| ||||||||||
| SINGLE WALL CONNECTOR |
|
| SINGLE WALL CONNECTOR |
|
| SIDEWALL |
| SIDEWALL |
| |||||||||
SIDEWALL | A 330 mm / 13 in | D 635 mm / 25 | in | SIDEWALL | A 380 mm /15 | in | D 685 | mm / 27 | in |
| G | G |
|
| |||||
|
| H | J |
|
|
| |||||||||||||
BACKWALL | B 280 mm / 11 in | E 445 mm / 17.5in | BACKWALL | B 265 mm / 10.5in | E 430 | mm / 17 | in |
|
|
|
|
|
|
| |||||
CORNER | C 205 mm / 8 | in | F 510 mm / 20 | in | CORNER | C 280 mm / 11 | in | F 585 | mm / 23 | in |
|
|
|
|
|
|
| ||
INSTALLATION USING LISTED DOUBLE WALL | INSTALLATION USING LISTED DOUBLE WALL |
|
|
|
|
|
|
|
| ||||||||||
| CONNECTOR - MOBILE HOME |
| CONNECTOR - MOBILE HOME |
|
|
| I |
|
|
|
| ||||||||
SIDEWALL | A 280 mm / 11 in | D 585 | mm / 23 | in | SIDEWALL | A 330 mm / 13 in | D 635 | mm / 25 in |
|
|
|
|
|
| |||||
|
|
|
|
|
|
| |||||||||||||
BACKWALL | B 150 mm / 6 | in | E 320 | mm / 12.5in | BACKWALL | B 125 mm / 5 | in | E 290 | mm / 11.5in |
|
| ADJACENT WALL |
|
| |||||
CORNER | C 150 mm / 6 | in | F 460 | mm / 18 | in | CORNER | C 230 mm / 9 | in | F 535 | mm / 21 | in |
|
|
|
| ||||
| SIDEWALL | F |
|
|
|
| |||||||||||||
SIDEWALL | A 230 mm / 9 | in | D 535 | mm / 21 | in | SIDEWALL | A 345 mm / 13.5in | D 650 | mm / 25.5in |
|
|
|
|
| |||||
|
|
|
|
|
|
| INSTALLATION USING LISTED DOUBLE WALL |
|
| C |
|
|
|
| |||||
INSTALLATION USING LISTED DOUBLE WALL |
|
|
|
|
|
|
|
| |||||||||||
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE | CONNECTOR - RESIDENTIAL CLOSE CLEARANCE |
|
|
|
|
|
|
| |||||||||||
BACKWALL | B 125 mm / 5 | in | E 290 | mm / 11.5in | BACKWALL | B 125 mm / 5 | in | E 290 | mm / 11.5in |
|
|
|
|
|
|
| |||
CORNER | C 75 | mm / 3 | in | F 380 | mm / 15 | in | CORNER | C 125 mm / 5 | in | F 430 | mm / 17 | in |
|
|
|
| BACK M | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FLOOR |
| |||
INSTALLATION USING LISTED DOUBLE WALL | INSTALLATION USING LISTED DOUBLE WALL |
|
|
|
|
|
| L | |||||||||||
|
| PROTECTION* |
|
|
| ||||||||||||||
| CONNECTOR - ALCOVE |
|
|
| CONNECTOR - ALCOVE |
|
|
|
| SIDE |
| SIDE | |||||||
SIDEWALL | mm / 23 | in | SIDEWALL | mm / 25 | in | K 405 mm / 16 in |
| ||||||||||||
G 280 mm / 11 in | I 585 | G 330 mm / 13 in | I 635 |
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
BACKWALL | H 180 mm / 7 | in | J 345 | mm / 13.5in | BACKWALL | H 125 mm / 5 | in | J 290 | mm / 11.5in | L 150 mm / 6 in |
|
|
| ||||||
M | 150 mm / 6 in |
| K | FRONT | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT | MAXIMUM ALCOVE DEPTH 915 MM / 36 IN. | * In Canada, floor protection must | |
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18" | extend 18" to the front and 8" to | ||
each side of the stove. | |||
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE. |
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD
IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL DVL, GSW SUPER PIPE 6,
| MANUFACTURED BY: FIREPLACE PRODUCTS INTERNATIONAL LTD. |
| 6988 VENTURE ST. |
| DELTA, BC V4G 1H4 |
| MADE IN CANADA |
|
|
UNITED STATES ENVIRONMENTAL | CERTIFIED TO COMPLY WITH JULY 1990, |
PROTECTION AGENCY | PARTICULATE EMISSION STANDARDS. |
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, |
|
|
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
| CLOTHING AND FURNITUREAWAY. CONTACT MAY CAUSE |
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
| SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS. | WD | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 01/03 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC
MANUFACTURE | 2002 |
| 2003 |
DATE OF | 2001 |
4 | Regency Freestanding Woodstove |