SAFETY LABEL
This is a copy of the label that accompanies each Regency Medium Freestanding Wood- stove (F2100M). It is located in the upper right
corner of the back of the stove. We have printed a copy of the contents here for your review.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
|
|
|
|
|
|
|
| LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO | DO NOT REMOVE THIS LABEL | ||||
|
|
|
|
|
|
|
| SUITABLE FOR MOBILE HOME INSTALLATION | 101 |
| |||
MODEL: REGENCY MEDIUM FREESTANDING STOVE - F2100M |
|
| |||||||||||
|
| ||||||||||||
TESTED TO: | CSA B366.2 / ULC S627 / UL 1482 REPORT NO.6622 (FEB.1993) | ||||||||||||
|
|
|
|
|
|
|
|
|
|
| INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING | ||
|
|
|
|
|
|
|
|
|
|
| INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND | ||
|
|
|
|
|
|
|
|
|
|
| INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR | ||
|
|
|
|
|
|
|
|
|
|
| 26 MSG BLUED STEEL CONNECTOR WITH LISTED | ||
|
|
|
|
|
|
|
|
|
|
| SOLID FUELS OR MASONRY CHIMNEY. |
|
|
|
|
|
|
|
|
|
|
|
|
| SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED | ||
| F2100M WITH | F2100M WITHOUT | FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY | ||||||||||
AIRMATE SHIELD AIRMATE SHIELD | CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY | ||||||||||||
FLUE SERVING ANOTHER APPLIANCE. | BACKWALL | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
OCT NOV DEC
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
| F2100M WITH AIRMATE SHIELD | F2100M WITHOUT AIRMATE SHIELD |
|
| |||||||||||
| MEASURE |
|
|
|
|
| FLUE | MEASURE |
|
|
|
| FLUE |
|
|
| FROM |
|
| HEATER |
| FROM |
| HEATER |
| ||||||
| RESIDENTIAL INSTALLATION USING | RESIDENTIAL INSTALLATION USING |
|
| |||||||||||
|
|
| SINGLE WALL CONNECTOR |
|
| SINGLE WALL CONNECTOR |
|
| |||||||
| SIDEWALL |
| A 355 mm / 14 in |
| D 660 | mm / 26 in | SIDEWALL |
| A 430 mm / 17 in |
| D 735mm / 29in |
|
| ||
|
|
| BACKWALL |
| B 280 mm / 11 in |
| E 445mm / 17.5in | ||||||||
| BACKWALL |
| B 255 mm / 10 in |
| E 420 | mm / 16.5 in |
|
| |||||||
| CORNER |
| C 190 mm / 7.5 in |
| F 510 | mm / 20 in | CORNER |
| C 230 mm / 9 in |
| F 535 mm / 21 in | ||||
|
|
|
|
|
|
|
|
|
|
| |||||
| INSTALLATION USING LISTED DOUBLE WALL | INSTALLATION USING LISTED DOUBLE WALL |
|
| |||||||||||
|
| CONNECTOR - MOBILE HOME | CONNECTOR - MOBILE HOME |
|
| ||||||||||
| SIDEWALL |
| A 405 mm / 16 in |
| D 725 | mm / 28.5in | SIDEWALL |
| A 460 mm / 18 in |
| D 775 | mm / 30.5 in | |||
|
|
|
|
| |||||||||||
| BACKWALL |
| B 215 mm / 8.5in |
| E 395 | mm / 15.5in | BACKWALL |
| B 215 mm / 8.5in |
| E 395 | mm / 15.5in | |||
| CORNER |
| C 190 mm / 7.5in |
| F 510 mm / 20 in | CORNER |
| C 215 mm / 8.5in |
| F 535 | mm / 21 | in | |||
|
|
|
|
|
|
|
|
|
|
|
| ||||
| INSTALLATION USING LISTED DOUBLE WALL | INSTALLATION USING LISTED DOUBLE WALL |
|
| |||||||||||
| CONNECTOR - RESIDENTIAL CLOSE CLEARANCE | CONNECTOR - RESIDENTIAL CLOSE CLEARANCE | |||||||||||||
| SIDEWALL |
| A 255 | mm / 10 in |
| D 550 | mm / 22.5 in | SIDEWALL |
| A 355 mm / 14 in |
| D 675 | mm / 26.5in | ||
| BACKWALL |
| B 115 | mm / 4.5 in |
| E 290 | mm / 11.5 in | BACKWALL |
| B 180 mm / 7 in |
| E 355 | mm / 14 | in | |
| CORNER |
| C 150 mm / 6 in |
| F 445 mm / 17.5 in | CORNER |
| C 215 mm / 8.5in |
| F 535 | mm / 21 | in | |||
|
|
|
|
|
|
|
|
| |||||||
| INSTALLATION USING LISTED DOUBLE WALL | INSTALLATION USING LISTED DOUBLE WALL |
|
| |||||||||||
|
|
| CONNECTOR - ALCOVE |
|
|
| CONNECTOR - ALCOVE |
|
|
| |||||
| SIDEWALL |
| G 255 mm / 10 in |
| I 570 | mm / 22.5in | SIDEWALL |
| G 355 mm / 14 in |
| I 675 | mm / 26.5in | |||
| BACKWALL |
| H 115 mm / 4.5in |
| J 290 | mm / 11.5in | BACKWALL |
| H 180 mm / 7 in |
| J 355 | mm / 14 | in | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SIDEWALL |
| B |
| E |
|
|
| |
|
|
|
|
|
| |||
| A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| D |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| BACKWALL |
|
| |||||
SIDEWALL | G | J | G |
| SIDEWALL | |||
|
| H |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
I
ADJACENT WALL
SIDEWALL | C |
F |
| FLOOR |
| BACK M | |||
| PROTECTION* |
|
|
| L | |
| SIDE |
|
| SIDE | ||
K | 405 mm / | 16 in |
|
| ||
|
| |||||
L | 150 mm / | 6 in | K | FRONT | ||
M 150 mm / | 6 in |
APR MAY JUN JUL AUG SEPT
MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT | MAXIMUM ALCOVE DEPTH 915 MM / 36 IN. | * In Canada, floor protection must | |
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18" | |||
extend 18" to the front and 8" to | |||
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE. | each side of the stove. |
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD
IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL DVL, GSW SUPER PIPE 6,
JAN FEB MAR
| MANUFACTURED BY: FIREPLACE PRODUCTS INTERNATIONAL LTD. |
| 6988 VENTURE ST. |
| DELTA, BC V4G 1H4 |
| MADE IN CANADA |
|
|
UNITED STATES ENVIRONMENTAL | CERTIFIED TO COMPLY WITH JULY 1990, |
PROTECTION AGENCY | PARTICULATE EMISSION STANDARDS. |
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITUREAWAY. CONTACT MAY CAUSE
WD
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
rev. 01/03
MANUFACTURE | 2002 2003 |
DATE OF | 2001 |
Regency Freestanding Woodstove | 5 |