INSTALLATION
TABLE 1
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
(Measured from the top of the unit)
|
|
| # OF ELBOWS |
|
|
|
| ||
ELEVATION (FT) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
ABOVE SEA LEVEL | 0 | 2 x 15o | 4 x 15o | 2 x 30o | 4 x 30o | 2 x 45o | 4 x 45o |
| |
|
|
|
|
|
|
|
|
|
|
| 12.0 | 13.0 | 14.0 | 15.0 | 18.0 | 16.0 | 20.0 |
| |
| 12.5 | 13.5 | 14.5 | 15.5 | 19.0 | 16.5 | 21.0 |
| |
| 13.0 | 14.0 | 15.0 | 16.0 | 19.5 | 17.0 | 21.5 |
| |
| 13.5 | 14.5 | 15.5 | 17.0 | 20.0 | 18.0 | 22.5 |
| |
| 14.0 | 15.0 | 16.0 | 17.5 | 21.0 | 18.5 | 23.0 |
| |
| 14.5 | 15.5 | 17.0 | 18.0 | 21.5 | 19.0 | 24.0 |
| |
| 15.0 | 16.0 | 17.5 | 18.5 | 22.5 | 20.0 | 25.0 |
| |
| 15.5 | 16.5 | 18.0 | 19.0 | 23.0 | 20.5 | 25.5 |
| |
| 16.0 | 17.0 | 18.5 | 20.0 | 24.0 | 21.0 | 26.5 |
| |
| 16.5 | 17.5 | 19.0 | 20.5 | 24.5 | 22.0 | 27.0 |
| |
|
|
|
|
|
|
|
|
|
|
NOTE: No more than two offsets (four elbows) allowed. Two 45o elbows equal one 90o elbow.
RECOMMENDED
HEIGHTS FOR
WOODSTOVE FLUE
Simple rules on draft. See Table 1.
1)At sea level minimum height is 12' straight.
2)Add the following vertical height to com- pensate for:
45 deg. elbow = 1 ft.
90 deg. elbow = 2 ft.
"T"= 3 ft.
Each foot of horizontal run = 2 ft.
3)Add 4% overall for each 1000' above sea level.
Example: a) |
|
|
= 3 ft. | ||
one "T" |
| = 3 ft. |
Total Addition (at sea level) | = 6 ft. | |
Example: b) |
|
|
One 90 deg. elbow | = 2 ft. | |
2 ft. of horizontal run | = 4 ft. | |
one "T" |
| = 3 ft. |
Total Addition (at sea level) | = 9 ft. | |
Recommended Flue Height | ||
Elevation | Example a) | Example b) |
0' | 18' | 21' |
1000' | 18.72' | 21.84' |
2000' | 19.44' | 22.68' |
5000' | 21.60' | 25.20' |
8000' | 23.76' | 27.72' |
MOBILE HOME INSTALLATION
Once you have properly marked the position of your unit and the floor protection as outlined in the Residential Installation items #1 through #8, a supply of fresh air has to be supplied to your unit. Cut a minimum 4 inch diameter hole through your floor protector and the floor directly under your pedestal base to the outside. Use 4" duct pipe with a mesh grill to pipe fresh air into the pedestal area. Block off the hole in the back of the pedestal with the square plate and the two 1/2" screws provided.
Place your unit in position and secure it to the floor using two lag bolts 3/8" x
For Mobile Home units installed in the U.S. the unit must be grounded using a #8 ground wire with approved termination and star washer.
14 | Regency Freestanding Woodstove |