SAFETY LABEL
This is a copy of the label that accompanies each Regency Large Freestanding Woodstove (F3100L). It is located in the upper right corner
of the back of the stove. We have printed a copy of the contents here for your review.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
|
|
|
|
|
| LISTED SPACE HEATER, SOLID FUEL TYPE, SUITABLE FOR | DO NOT REMOVE THIS LABEL | |||||||||
|
|
|
|
|
| MOBILE HOME INSTALLATION |
|
|
|
|
| |||||
|
|
|
|
|
|
| 102 |
|
|
| ||||||
|
|
|
|
|
| MODEL: | REGENCY LARGE FREESTANDING STOVE - F3100L |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |||||||
TESTED TO: | CSA B366.2 / ULC S627 / UL 1482 REPORT NO.6623 (MAY 93) |
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERAT- | |||||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| ING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND | |||||
|
|
|
|
|
|
|
|
|
|
| INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR | |||||
|
|
|
|
|
|
|
|
|
|
| 26 MSG BLUED STEEL CONNECTOR WITH LISTED | |||||
|
|
|
|
|
|
|
|
|
|
| SOLID FUELS OR MASONRY CHIMNEY. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED | |||||
|
|
|
|
|
|
|
|
|
|
| ||||||
| F3100L WITH | F3100L WITHOUT | FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY | |||||||||||||
| CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY | |||||||||||||||
AIRMATE SHIELD AIRMATE SHIELD | FLUE SERVING ANOTHER APPLIANCE. |
|
| BACKWALL |
|
F3100L WITH AIRMATE SHIELD |
| F3100L WITHOUT AIRMATE SHIELD |
| SIDEWALL | B | E |
|
| |||||
| MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| A |
|
|
|
MEASURE |
| FLUE |
| MEASURE |
|
| FLUE |
|
| D |
|
|
|
FROM | HEATER |
| FROM | HEATER |
|
|
|
|
|
|
| ||
RESIDENTIAL INSTALLATION USING |
| RESIDENTIAL INSTALLATION USING |
|
| BACKWALL |
|
| ||||||
CORNER | SINGLE WALL CONNECTOR | in | CORNER | SINGLE WALL CONNECTOR | in | SIDEWALL | G | G | SIDEWALL |
| |||
C 215 mm / 8.5in | F 560 mm / 22 | C 265 mm / 10.5in | F 610 mm / 24 |
| |||||||||
SIDEWALL | A 460 mm / 18 in | D 810 mm / 32 | in | SIDEWALL | A 510 mm / 20 | in | D 860 mm / 34 | in |
| H | J |
|
|
BACKWALL | B 305 mm / 12 in | E 470 mm / 18.5in | BACKWALL | B 355 mm / 14 | in | E 520 mm / 20.5 in |
|
|
|
|
| ||
INSTALLATION USING LISTED DOUBLE WALL |
| INSTALLATION USING LISTED DOUBLE WALL |
|
| I |
|
|
| |||||
CONNECTOR - MOBILE HOME |
| CONNECTOR - MOBILE HOME |
|
|
|
|
| ||||||
SIDEWALL | A 460 mm / 18 in | D 810 mm / 32 | in | SIDEWALL | A 510 mm / 20 in | D 860 mm / 34 in |
| ADJACENT WALL |
|
| |||
BACKWALL | B 240 mm / 9.5in | E 405 mm / 16 | in | BACKWALL | B 305 mm / 12 in | E 470 mm / 18.5in |
|
|
| ||||
SIDEWALL | C |
|
|
| |||||||||
CORNER | C 255 mm / 10 in | F 595 mm / 23.5in | CORNER | C 255 mm / 10 in | F 595 mm / 23.5in |
|
|
| |||||
|
|
|
| ||||||||||
INSTALLATION USING LISTED DOUBLE WALL |
| INSTALLATION USING LISTED DOUBLE WALL |
|
|
|
|
| ||||||
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE | CONNECTOR - RESIDENTIAL CLOSE CLEARANCE | F |
|
|
| ||||||||
SIDEWALL | A 405 mm / 16 in | D 760 mm / 30 | in | SIDEWALL | A 510 mm / 20 in | D 860 mm / 34 | in |
|
|
| BACK M | ||
BACKWALL | B 240 mm / 9.5in | E 405 mm / 16 | in | BACKWALL | B 305 mm / 12 in | E 470 mm / 18.5in | FLOOR |
| |||||
CORNER | C 215 mm / 8.5in | F 560 mm / 22 | in | CORNER | C 215 mm / 8.5in | F 560 mm / 22 | in |
|
| L | |||
|
|
|
|
|
|
|
| PROTECTION* |
| SIDE | SIDE | ||
INSTALLATION USING LISTED DOUBLE WALL |
|
|
|
|
| K | 405 mm / 16 in | ||||||
| CONNECTOR - ALCOVE |
|
| ALCOVE INSTALLATION | L | 150 mm / 6 in | K | FRONT | |||||
SIDEWALL | G 405 mm / 16 in | I 760 mm / 30 | in |
| REQUIRES AIRMATE SHIELD | M | 150 mm / 6 in | ||||||
|
|
| |||||||||||
BACKWALL | H 240 mm / 9.5in | J 405 mm / 16 | in |
|
|
|
|
| * In Canada, floor protection must | ||||
|
|
|
|
|
|
|
|
| extend 18" to the front and 8" to | ||||
|
|
|
|
|
|
|
|
| each side of the stove. |
|
MINIMUM CLEARANCE BETWEEN HORIZONTAL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS - 460 MM (18 IN.). CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM GLASS.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD
IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL DVL, GSW SUPER PIPE 6,
MANUFACTURED BY: FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 VENTURE ST.
DELTA, BC V4G 1H4
MADE IN CANADA
UNITED STATES ENVIRONMENTAL | CERTIFIED TO COMPLY WITH JULY 1990, |
PROTECTION AGENCY | PARTICULATE EMISSION STANDARDS. |
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
WD
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
01/03
JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC
MANUFACTURE | 2002 |
| 2003 |
DATE OF | 2001 |
6 | Regency Freestanding Woodstove |