INSTALLATION
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Please read the section below carefully as clearances depend on whether the airmate or the rear heat deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.
Residential Installation “C” Vent | (Single Wall) |
|
|
|
| ||||
Unit |
|
|
| From Unit | From Corner | From Flue | |||
|
|
| A |
| B | C | D | E | F |
Small F1100S | with | Airmate | 13" |
| 11" | 8" | 25" | 17.5" | 20" |
| with | Rear Deflector | 15" |
| 10.5" | 11" | 27" | 17" | 23" |
Medium F2100M | with Airmate | 14" |
| 10" | 6" | 26" | 16.5" | 17.5" | |
| with | Rear Deflector | 17" |
| 11" | 9" | 29" | 17.5" | 21" |
Medium S2100M Step Stove | 14" |
| 10" | 6" | 26" | 16.5" | 17.5" | ||
Large F3100L | with | Airmate | 18" |
| 12" | 8.5" | 32" | 18.5" | 22" |
| with | Rear Deflector | 20" |
| 14" | 10.5" | 34" | 20.5" | 24" |
Large S3100L Step Stove | 18" |
| 12" | 8.5" | 32" | 18.5" | 22" | ||
|
|
|
|
|
|
|
|
|
|
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.
Unit |
|
|
|
| From Unit |
| From Corner | From Flue |
| |||
|
|
|
| A |
| B | C |
| D | E | F | |
Small F1100S | with | Airmate | 9" |
| 5" | 3" |
| 21" | 11.5" | 15" |
| |
| with | Rear | Deflector | 13.5" |
| 5" | 5" |
| 25.5" | 11.5" | 17" |
|
Medium F2100M | with Airmate | 10" |
| 4.5" | 7.5" |
| 22.5" | 11.5" | 20" |
| ||
| with | Rear | Deflector | 14" |
| 7" | 8.5" |
| 26.5" | 14" | 21" |
|
Medium S2100M Step Stove |
| 10" |
| 4.5" | 7.5" |
| 22.5" | 11.5" | 20" |
| ||
Large F3100L | with | Airmate | 16" |
| 9.5" | 8.5" |
| 30" | 16" | 22" |
| |
| with | Rear | Deflector | 20" |
| 12" | 8.5" |
| 34" | 18.5" | 22" |
|
Large S3100L Step Stove |
| 16" |
| 9.5" | 8.5" |
| 30" | 16" | 22" |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)
|
| Unit |
|
| From Unit |
| From Corner |
| From Flue |
| |||
|
|
|
|
|
|
| |||||||
|
|
|
| A |
| B | C |
| D |
| E | F |
|
|
| Small F1100S | with Airmate | 11" |
| 6" | 6" |
| 23" |
| 12.5" | 18" |
|
|
| with Rear | Deflector | 13" |
| 5" | 9" |
| 25" |
| 11.5" | 21" |
|
|
| Medium F2100M with Airmate | 16" |
| 8.5" | 7.5" |
| 28.5" |
| 15.5" | 20" |
| |
|
| with Rear | Deflector | 18" |
| 8.5" | 8.5" |
| 30.5" |
| 15.5" | 21" |
|
|
| Medium S2100M Step Stove | 16" |
| 8.5" | 7.5" |
| 28.5" |
| 15.5" | 20" |
| |
|
| Large F3100L | with Airmate | 18" |
| 9.5" | 10" |
| 32" |
| 16" | 23.5" |
|
|
| with Rear | Deflector | 20" |
| 12" | 10" |
| 34" |
| 18.5" | 23.5" |
|
|
| Large S3100L Step Stove | 18" |
| 9.5" | 10" |
| 32" |
| 16" | 23.5" |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|