Installation (For Qualified Installers Only)

Pellet Vent Type

Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc… ) must be sealed with 500° F. RTV silicone.

Installing the Pellet Vent

.RTV °F 500Silicone

Seal each vent section (including adapters, elbows, etc...) by

injecting a liberal amount of 500° F. RTV silicone into the gap between sections.

Horizontal sections must have a 1/4" rise every 12" of travel.

Pellet vent connections must be sealed airtight with 500° F. RTV silicone and screwed together with at least three sheet metal screws.

Pellet Vent Termination (See the illustration below)

Must have an approved cap (to prevent water from entering) or a 45° downturn.

If the termination is located on a windy side of the house, an approved house shield is recommended to prevent soot from building up on the side of the house.

Must not be located where it will become plugged by snow or other material.

Horizontal terminations must protrude 12" from the wall, verticall terminations require 24".

C

X

A

B

H F A

E

G

F

D

NOTE: Measure clearances to the nearest edge of the exhaust hood.

AMinimum 4' clearance below or beside any door or window that opens Minimum 1’ clearance below or beside any window that does not open.

BMinimum 1' clearance above any door or window that opens

CMinimum 2' clearance from any adjacent building

DMinimum 7' clearance above any grade when adjacent to public walkways NOTE: Vent may not terminate in covered walkway or breezeway.

EMinimum 2' clearance above any grass, plants, or other combustible materials

FMinimum 3' clearance from any forced air intake of any other appliance

GMinimum 2' clearance below eaves or overhangs

HMinimum 1' clearance horizontally from combustible wall

X

Must be a minimum of 2' above the roof

Travis Industries

4050418

1 0 0 - 0 1 1 5 6

Image 10
Contents Yankee Travis Industries 2IntroductionIntroduction Important Information 0 0 1 1 5Table of Contents 4Safety Precautions Mobile Home Specifications Stove Placement Installation OptionsPlanning The Installation Before You BeginClearances Straight Installation Clearances Corner InstallationVenting the Pellet Stove Maximum Venting DistancePellet Vent Type Installing the Pellet VentPellet Vent Termination See the illustration below Mobile Home Requirements Outside Air used for combustionRestrictor Adjustment Alcove Installation RequirementsBaffle Installation Door Seal VerificationInstallation Example Direct Through-the-wall Installation Installation Example Interior Vertical Installation Installation Example Class a Chimney Retrofit Installation Example Masonry Fireplace Hearth Stove Vent Flex SectionVertical Cap Cover Plate non-combustible Storm Collar Installation Example Freestanding Masonry Chimney Storm CollarLocation of Controls Safety NoticeOperation1 Starting the Heater for the First TimeLoading Pellets 0Operatio nTwo Modes of Operation Operation2 Manual ModeTo Adjust the Heat To StartTo Adjust Room Temperature or Start the Stove Auto Mode2Operation Adjusting the Fan Speed 4Operation Inspect the Burn Maintenance2Daily Maintenance whenever using the stove Make Sure Pellets are Not Piling UpCleaning the Firepot 6MaintenanceCheck Firepot for Clinkers Door Opening Door Frame Lock NutClean the Heat Exchange Tubes 8MaintenanceBi-Weekly Maintenance or every 10 bags of pellets Cleaning the Optional Gold Surfaces Door and optional GrillClean the Baffles Cleaning the Baffles0Maintenance Sweep Ash Into AshpanClean the Glass Maintenance3Check Ashpan, Dispose if necessary Clean the Exhaust Duct 2MaintenanceYearly Maintenance or every two tons Clean the Convection BlowerClean the Vent make sure the stove and vent is cool Door Seal 4MaintenanceDoor Alignment Adjusting the Door Hinge and Latch Latch AdjustmentReplacement Parts Check for Air Leaks Around the Door, Glass, and AshpanNormal Operating Sounds Exhaust BlowerSafety Label Serial NoLimited 7 Year Warranty Years 1 & 2 Coverage Parts & Labor0Optional Equipment ThermostatRemote Thermostat Using the Remote ThermostatOptional Equipment Pellet Log2Index