Installation (For Qualified Installers Only)

1 3

Thermostat Installation

!Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater).

A thermostat is included with this heater (part # 99300650). Follow the directions below to install.

1Attach the thermostat wire to the circuit board (see the illustration below). Route the wire through the back of the heater (away from any hot or moving components).

50

60

70

80

90

Pull the cover off the thermostat

50

60

70

80

90

Run the thermostat wires through the wall (cut off excess wire, leaving 6” of slack).

Attach the quick-connects to the two posts near the molex connector on the circuit board (orientation does not mater).

2Determine a location for the thermostat that is within range of the 20' length of thermostat wire. It should be centralized in the room and away from the heater. The wire may be routed externally on the wall or behind the wall (preferred).

3Follow the directions to the right to attach the thermostat and thermostat wires.

Expose 1/2” of wire and attach to these two posts.

Standard

Screwdriver

Attach the thermostat to the wall through these two holes.

Travis Industries

4061016

1 0 0 - 0 1 1 8 4

Image 13
Contents Leyden Introduction 2IntroductionImportant Information Travis IndustriesTable of Contents 4Safety Precautions Mobile Home Safety Precautions6Specifications Planning The Installation Installation OptionsStove Placement Before You BeginInstallation Clearances Straight InstallationClearances Corner Maximum Venting Distance Venting the Pellet StovePellet Vent Type Installing the Pellet VentPellet Vent Termination Outside Air used for combustion Mobile Home RequirementsBaffle Installation Alcove Installation RequirementsRestrictor Adjustment Door Seal VerificationThermostat Installation Installation Example Direct Through-the-wall Installation Min Ceiling Support / Fire Stop Spacer Vent Installation Example Interior Vertical InstallationInstallation Example Class a Chimney Retrofit Installation Example Masonry Fireplace Hearth Stove Vertical Cap Cover Plate non-combustible Storm Collar Vent Flex Section Installation Example Freestanding Masonry Chimney0Operation Safety NoticeLocation of Controls Starting the Heater for the First TimeLoading Pellets Operation2Two Modes of Operation To Adjust the Heat Manual Mode2Operation To StartTo Adjust Room Temperature or Start the Stove Auto Mode4Operation Adjusting the Fan SpeedPower Outages Fault LightStart-Up Sequence Manual Auger Button6Operation Using a Pellet/Corn Mix with This HeaterDaily Maintenance whenever using the stove Maintenance2Inspect the Burn Make Sure Pellets are Not Piling UpCleaning the Firepot 8MaintenanceCheck Firepot for Clinkers Door Opening Bi-Weekly Maintenance or every 10 bags of pellets 2MaintenanceBi-Weekly Maintenance or every 10 bags of pellets Maintenance3Clean the Baffles Sweep Ash Into Ashpan Check Ashpan, Dispose if necessary Clean the GlassYearly Maintenance or every two tons 4MaintenanceClean the Vertical Exhaust Duct Maintenance3 Clean the Exhaust Blower 6MaintenanceClean the Vent Clean the Convection BlowerAdjusting the Door Hinge and Latch Check for Air Leaks Around the Door, Glass, and AshpanDoor Replacement Replacement PartsReplacement Parts Convection Fan Normal Operating SoundsSafety Label Years 1 & 2 Coverage Parts & Labor Limited 7 Year Warranty2Index