Daily Maintenance (whenever using the stove) - Continued

Check Firepot for

Clinkers

If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers (ashes that solidify into a clump).

The most likely causes are:

• Restrictor needs adjustment (see “Restrictor Adjustment” in the installation section of this manual)

• Poor pellet quality

The door or glass has an air leak

The exhaust system requires cleaning

Cleaning the Firepot

WARNING:

Make sure the heater has fully cooled (approximately 25 minutes) before opening the door and conducting service.

To clean the firepot, open the door (see page 27) and knock away any debris on the firepot with a screwdriver. If severely clogged, remove the firepot to gain better access.

Travis Industries

4061016

1 0 0 - 0 1 1 8 4

Image 28
Contents Leyden 2Introduction IntroductionImportant Information Travis IndustriesTable of Contents 4Safety Precautions Safety Precautions Mobile Home6Specifications Installation Options Planning The InstallationStove Placement Before You BeginInstallation Clearances Straight InstallationClearances Corner Venting the Pellet Stove Maximum Venting DistancePellet Vent Type Installing the Pellet VentPellet Vent Termination Mobile Home Requirements Outside Air used for combustionAlcove Installation Requirements Baffle InstallationRestrictor Adjustment Door Seal VerificationThermostat Installation Installation Example Direct Through-the-wall Installation Installation Example Interior Vertical Installation Min Ceiling Support / Fire Stop Spacer VentInstallation Example Class a Chimney Retrofit Installation Example Masonry Fireplace Hearth Stove Vertical Cap Cover Plate non-combustible Storm Collar Installation Example Freestanding Masonry Chimney Vent Flex SectionSafety Notice 0OperationLocation of Controls Starting the Heater for the First TimeLoading Pellets Operation2Two Modes of Operation Manual Mode To Adjust the Heat2Operation To StartAuto Mode To Adjust Room Temperature or Start the StoveAdjusting the Fan Speed 4OperationFault Light Power OutagesStart-Up Sequence Manual Auger ButtonUsing a Pellet/Corn Mix with This Heater 6OperationMaintenance2 Daily Maintenance whenever using the stoveInspect the Burn Make Sure Pellets are Not Piling UpCleaning the Firepot 8MaintenanceCheck Firepot for Clinkers Door Opening 2Maintenance Bi-Weekly Maintenance or every 10 bags of pelletsBi-Weekly Maintenance or every 10 bags of pellets Maintenance3Clean the Baffles Sweep Ash Into Ashpan Clean the Glass Check Ashpan, Dispose if necessaryYearly Maintenance or every two tons 4MaintenanceClean the Vertical Exhaust Duct Maintenance3 6Maintenance Clean the Exhaust BlowerClean the Convection Blower Clean the VentAdjusting the Door Hinge and Latch Check for Air Leaks Around the Door, Glass, and AshpanDoor Replacement Replacement PartsReplacement Parts Normal Operating Sounds Convection FanSafety Label Limited 7 Year Warranty Years 1 & 2 Coverage Parts & Labor2Index