Lopi Leyden Pellet Stove manual 4Safety Precautions

Page 4

4Safety Precautions

Do not operate the heater if you smell smoke coming from the heater. Turn the M ODE switch to "OFF", monitor your heater, and call your dealer .

Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or 'freshen up' a fire in this heater. Keep all such liquids well away from the heater while it is in use.

Do not unplug the heater if you suspect a malfunction. Turn the MODE SWITCH to "OFF" and periodically inspect the heater.

Never try to repair or replace any part of the heater unless instructions are given in this manual. All other work should be done by a trained technician.

The viewing door and ashpan must be closed and latched during operation.

Never block free airflow through the open vents of the unit

Do not operate the heater if the flame becomes dark & sooty of if the firepot overfills with pellets. Turn the MODE SWITCH to "OFF" and periodically inspect the heater (see "Running Your Heater").

Ok

Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this heater as well.

The exhaust system must be completely airtight and properly installed. The pellet vent joints must be sealed with RTV 500o F. (260o C.) silicone sealant.

This unit must be properly installed to prevent the possibility of a house fire. The instructions must be strictly adhered to. Do not use makeshift methods or compromise in the installation.

Your heater requires periodic maintenance and cleaning (see "Maintaining Your Heater"). Failure to maintain your heater may lead to smoke spillage in your home.

Allow the heater to cool before carrying out any maintenance or cleaning. Ashes must be disposed in a metal container with a tight lid and placed on a non-combustible surface well away from the home or structure.

This heater is designed and approved for pelletized wood fuel or a mixture up to 50% corn, 50% pellets. See page 26 for details on using a corn pellet mix.

Travis Industries

4061016

1 0 0 - 0 1 1 8 4

Image 4
Contents Leyden 2Introduction IntroductionImportant Information Travis IndustriesTable of Contents 4Safety Precautions Safety Precautions Mobile Home6Specifications Installation Options Planning The InstallationStove Placement Before You BeginInstallation Clearances Straight InstallationClearances Corner Venting the Pellet Stove Maximum Venting DistancePellet Vent Type Installing the Pellet VentPellet Vent Termination Mobile Home Requirements Outside Air used for combustionAlcove Installation Requirements Baffle InstallationRestrictor Adjustment Door Seal VerificationThermostat Installation Installation Example Direct Through-the-wall Installation Installation Example Interior Vertical Installation Min Ceiling Support / Fire Stop Spacer VentInstallation Example Class a Chimney Retrofit Installation Example Masonry Fireplace Hearth Stove Vertical Cap Cover Plate non-combustible Storm Collar Installation Example Freestanding Masonry Chimney Vent Flex SectionSafety Notice 0OperationLocation of Controls Starting the Heater for the First TimeLoading Pellets Operation2Two Modes of Operation Manual Mode To Adjust the Heat2Operation To StartAuto Mode To Adjust Room Temperature or Start the StoveAdjusting the Fan Speed 4OperationFault Light Power OutagesStart-Up Sequence Manual Auger ButtonUsing a Pellet/Corn Mix with This Heater 6OperationMaintenance2 Daily Maintenance whenever using the stoveInspect the Burn Make Sure Pellets are Not Piling UpCleaning the Firepot 8MaintenanceCheck Firepot for Clinkers Door Opening 2Maintenance Bi-Weekly Maintenance or every 10 bags of pelletsBi-Weekly Maintenance or every 10 bags of pellets Maintenance3Clean the Baffles Sweep Ash Into Ashpan Clean the Glass Check Ashpan, Dispose if necessaryYearly Maintenance or every two tons 4MaintenanceClean the Vertical Exhaust Duct Maintenance3 6Maintenance Clean the Exhaust BlowerClean the Convection Blower Clean the VentAdjusting the Door Hinge and Latch Check for Air Leaks Around the Door, Glass, and AshpanDoor Replacement Replacement PartsReplacement Parts Normal Operating Sounds Convection FanSafety Label Limited 7 Year Warranty Years 1 & 2 Coverage Parts & Labor2Index