Lopi Leyden Pellet Stove manual 6Maintenance, Clean the Exhaust Blower

Page 36

3 6Maintenance

Yearly Maintenance (or every two tons) - continued

Clean the Exhaust Blower

The exhaust blower cover is held in place with 4 screws.

Remove the side cover.

Remove the cover plate on the exhaust blower. Clean the area inside the blower, removing all flyash.

Remove these 3 nuts to expose the exhaust blower.

Flow Switch Tube

Use the bottle brush to disoldge any flyash near the exahust blower and in the horizontal exhaust channel. Take care to not damage the impeller on the exhaust blower.

Nipple (attached to exhaust channel)

Check the nipple and flow switch tube. Insert a pipe cleaner through the nipple to dislodge any flyash. NOTE: The flow switch will shut off the auger if the tube becomes clogged or dislodged. Make sure it is cleaned out and correctly attached.

Travis Industries

4061016

1 0 0 - 0 1 1 8 4

Image 36
Contents Leyden 2Introduction IntroductionImportant Information Travis IndustriesTable of Contents 4Safety Precautions Safety Precautions Mobile Home6Specifications Installation Options Planning The InstallationStove Placement Before You BeginClearances Straight Installation InstallationClearances Corner Venting the Pellet Stove Maximum Venting DistanceInstalling the Pellet Vent Pellet Vent TypePellet Vent Termination Mobile Home Requirements Outside Air used for combustionAlcove Installation Requirements Baffle InstallationRestrictor Adjustment Door Seal VerificationThermostat Installation Installation Example Direct Through-the-wall Installation Installation Example Interior Vertical Installation Min Ceiling Support / Fire Stop Spacer VentInstallation Example Class a Chimney Retrofit Installation Example Masonry Fireplace Hearth Stove Vertical Cap Cover Plate non-combustible Storm Collar Installation Example Freestanding Masonry Chimney Vent Flex SectionSafety Notice 0OperationLocation of Controls Starting the Heater for the First TimeOperation2 Loading PelletsTwo Modes of Operation Manual Mode To Adjust the Heat2Operation To StartAuto Mode To Adjust Room Temperature or Start the StoveAdjusting the Fan Speed 4OperationFault Light Power OutagesStart-Up Sequence Manual Auger ButtonUsing a Pellet/Corn Mix with This Heater 6OperationMaintenance2 Daily Maintenance whenever using the stoveInspect the Burn Make Sure Pellets are Not Piling Up8Maintenance Cleaning the FirepotCheck Firepot for Clinkers Door Opening 2Maintenance Bi-Weekly Maintenance or every 10 bags of pelletsMaintenance3 Bi-Weekly Maintenance or every 10 bags of pelletsClean the Baffles Sweep Ash Into Ashpan Clean the Glass Check Ashpan, Dispose if necessary4Maintenance Yearly Maintenance or every two tonsClean the Vertical Exhaust Duct Maintenance3 6Maintenance Clean the Exhaust BlowerClean the Convection Blower Clean the VentAdjusting the Door Hinge and Latch Check for Air Leaks Around the Door, Glass, and AshpanReplacement Parts Door ReplacementReplacement Parts Normal Operating Sounds Convection FanSafety Label Limited 7 Year Warranty Years 1 & 2 Coverage Parts & Labor2Index