Regency L234-NG, L234-LP installation manual GAS Pipe Pressure Testing, SIT Valve Description

Page 13

INSTALLATION

GAS PIPE

PRESSURE TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.

The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.

NOTE: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1)Make sure the valve is in the "OFF" position.

2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide fl at screwdriver.

3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.

4)Light the pilot and turn the valve to "ON" position.

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.

6)When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver.

Note: Screw should be snug, but do not over tighten.

SIT VALVE DESCRIPTION

1)Gas on/off knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection - option

5)Manifold (Outlet) Pressure Tap

6)Inlet Pressure Tap

7)Pilot Outlet

8)Main Gas Outlet

9)Alternative TC Connection Point

1

2

3

4

IN OUT

6 5

INSTALLATION

Regency® L234 Direct Vent Gas Insert

13

Image 13
Contents L234 Gas Insert Regency GAS Fireplace Insert Table of Contents Safety Label MA Code CO Detector RequirementsUnit & Faceplate Dimensions Installation Materials Required Installation ChecklistMinimum Fireplace Opening Minimum Clearances to Combustible Mantel Combustibles Venting Installation with 3 & 3 LinersConverting from 3 & 3 Venting to 3 Vent Restrictor PositionGAS Insert Aeration System Flue Liner GAS Connection InstallationSIT Valve Description GAS Pipe Pressure TestingTop Mounting Bracket Conversion KIT #536-969 from NG to LPBurner Removed Spring HookRemove burner orifice with a 1/2 wrench Optional Brick Panel Installation Contour or Contemporary Faceplate Faceplate Contents ListRemote Receiver Bracket DC SparkerCompleted Faceplate Installation Attach Top Backing Plate to Faceplate Optional Backing PlateAttach Faceplate & Top Backing Plate to Unit Attach Left & Right Backing Plate to Faceplate Attach Left & Right Corner Backing PlateCustomize Hearth Trim Optional Hearth Trim711 713 7152-716 712 714 LOG SET InstallationTab NotchRight side of Burner Completed Log Set Installation Wiring Diagrams Optional Wall Thermostat Optional Remote ControlFinal Check Shutdown Procedure Lighting ProcedureOperating Instructions First FireFAN Operation Copy of Lighting Instruction PlateMaintenance FAN Replacement Connector Clips DC Sparker Wires Valve ReplacementValve Removed Main Assembly Parts ListFaceplate Assembly Backing Plate & Hearth Trim Assembly Conditions WarrantyInstaller Please complete the following information