Regency L234-NG, L234-LP installation manual Installation

Page 7

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The FPI Direct Vent Gas Insert must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Con- sult the building authority having jurisdiction to determine the need for a permit prior to starting the installation.

NOTE: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or property damage. Failure to follow these instructions may also void your fi re insurance and/or warranty.

FOR YOUR SAFETY

Thisappliancerequiresairforpropercombustion. Always provide adequate combustion and ventilationair. Followinstructionsandinformation in CSA B149.1 (in Canada) or the National Fuel Gas Code ANS Z223.1/NFPA (in the USA), regarding requirements for combustion and ventilation air.

GAS PRESSURE

TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than

1/2 psig. (3.45 kPa).

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit must be disconnected.

Gas Input Capacity:

Natural Gas 23,500 Btu/h

Propane

21,500 Btu/h

Min. Input:

Natural Gas 12,500 Btu/h

Propane

11,000 Btu/h

Fuels: Approved for use with both natural gas, and propane. Approved as is for use at 0' to

4,500' (0-1370m).

Electrical: 120V A.C. system.

Circulation Fan: Variable speed, 127 CFM.

Log Set: Ceramic fi bre, 6 per set.

Vent System: 3" co-linear aluminum fl ex or 2" intake with 3" exhaust.

INSTALLATION INTO A SOLID FUEL BURNING FIREPLACE OR FACTORY BUILT FIREPLACE

The L234 Gas Inserts have been tested and approved to be vented into any masonry fireplace or approved solid fuel burning factory built fi replace that will allow the insert to physically fi t into the fi rebox. Refer to the "Minimum Fireplace Opening" section.

If the factory built fireplace* height is too low for your Insert, you may remove the smoke baffle plate and damper from the factory built fireplace as long as these items are saved and are reinstalled in the event that the Insert is removed. NOTE:Any alterations made to the listed solid fuel burning factory built fireplace may void the listing of the fireplace. Cutting any sheet-metal parts of thefireplace,inwhichthegasfireplaceinsert is to be installed, is prohibited.

If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5" (37.5mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be plugged with non- combustible insulation after the gas supply line has been installed.

The fireplace and fireplace chimney must be clean and in good working order and constructed of non-combustible materials and chimney cleanouts must fit properly. Refractory, glass doors, screen rails, screen mesh, and log grates can be removed from the fireplace before installing the gas fireplace insert. Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners. A tight seal between the gas fireplace insert flue collar and the fireplace chimney must be made to prevent heat loss.

*Check with your local inspector before commencing with this installation.

Installer must mechanically attach the supplied label to the inside of the fi rebox of the fi replace into which the gas fi replace insert is installed.

"WARNING:This fireplace has been converted for use with a gas fi replace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fi replace re-approved by the authority having jurisdiction."

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

General Safety Information

1)The appliance installation must conform with local codes or in the absence of local codes, with CAN/CSA B149.1 (in Canada) or the National Fuel Gas CodeANSI Z223.1 NFPA54 in the U.S.A.This appliance should beinstalledbyaqualifiedgasfittertechnician only.

2)Installation and repair should be done by a qualified service person.

3)The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, animal hair, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

4)See general construction and assembly

instructions. This appliance may only be installed in a vented, noncombustible

replace.

5)This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

6)Always connect this appliance to a vent system vent that is run (or routed) to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is properly sized and is of adequate height to provide the proper draft.

7)Inspect the venting system annually for blockage and any signs of deterioration.

8)Any glass removed for servicing must be replaced prior to operating the appliance.

9)WARNING: Failure to position the parts in accordance with the diagrams in this manual or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

10)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the

replace.

INSTALLATION

Regency® L234 Direct Vent Gas Insert

7

Image 7
Contents L234 Gas Insert Regency GAS Fireplace Insert Table of Contents Safety Label MA Code CO Detector RequirementsUnit & Faceplate Dimensions Installation Materials Required Installation ChecklistMinimum Fireplace Opening Minimum Clearances to Combustible Mantel Combustibles Venting Installation with 3 & 3 LinersConverting from 3 & 3 Venting to 3 Vent Restrictor PositionGAS Insert Aeration System Flue Liner GAS Connection InstallationSIT Valve Description GAS Pipe Pressure TestingSpring Hook Conversion KIT #536-969 from NG to LPTop Mounting Bracket Burner RemovedRemove burner orifice with a 1/2 wrench Optional Brick Panel Installation Contour or Contemporary Faceplate Faceplate Contents ListRemote Receiver Bracket DC SparkerCompleted Faceplate Installation Attach Top Backing Plate to Faceplate Optional Backing PlateAttach Faceplate & Top Backing Plate to Unit Attach Left & Right Backing Plate to Faceplate Attach Left & Right Corner Backing PlateCustomize Hearth Trim Optional Hearth Trim711 713 7152-716 712 714 LOG SET InstallationTab NotchRight side of Burner Completed Log Set Installation Wiring Diagrams Optional Wall Thermostat Optional Remote ControlFinal Check First Fire Lighting ProcedureShutdown Procedure Operating InstructionsFAN Operation Copy of Lighting Instruction PlateMaintenance FAN Replacement Connector Clips DC Sparker Wires Valve ReplacementValve Removed Main Assembly Parts ListFaceplate Assembly Backing Plate & Hearth Trim Assembly Conditions WarrantyInstaller Please complete the following information

L234-NG, L234-LP specifications

The Regency L234-LP and L234-NG are elegant and efficient gas fireplaces that exemplify modern design and advanced technology. These models are ideal for homeowners looking to enhance their living spaces with warmth and aesthetics. With a variety of features, the Regency L234 fireplace series stands out in both functionality and style.

One of the key characteristics of the L234 series is its choice between liquid propane (LP) and natural gas (NG) configurations, providing flexibility for various installation needs. This adaptability allows homeowners to select the fuel type that best suits their preferences and available resources.

In terms of design, the L234 fireplaces feature a contemporary clean face style, which emphasizes the stunning flames while minimizing distractions. The large viewing area is framed by a sleek, minimalist design that fits effortlessly into modern interiors. With customizable options, including different decorative media such as glass and stones, consumers can personalize the appearance of their fireplace to match their home decor.

Efficiency is another hallmark of the Regency L234 series. With its high-efficiency rating, this fireplace not only produces warmth but does so while minimizing fuel consumption. The incorporation of advanced technology such as a direct vent system allows for safe and efficient combustion, drawing in outdoor air for combustion and venting exhaust gases outside. This feature enhances the overall efficiency of the unit, ensuring the living space remains warm and comfortable.

The L234 also comes equipped with a user-friendly remote control, simplifying the operation and allowing users to adjust flame height and heat output from a distance. This remote capability enhances convenience and allows for immediate adjustments based on comfort levels.

Safety features are paramount in the design of the Regency L234 fireplaces. The units are equipped with automatic shut-off systems and advanced safety screens to prevent accidents, providing peace of mind to homeowners.

Overall, the Regency L234-LP and L234-NG gas fireplaces are exemplary choices for those seeking a blend of modern design, efficiency, and safety. With their customizable features and advanced technologies, they provide not only heating solutions but also a stylish focal point for any room. As homeowners seek eco-friendly alternatives that do not compromise on style, the Regency L234 series stands out as a top contender in the market.