Regency L234-NG, L234-LP installation manual Maintenance

Page 31

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1) Always turn the gas valve to the off position

before cleaning. For relighting, refer to

lighting instructions. Keep the burner and

control compartment clean by brushing and

vacuuming at least once a year.

When cleaning the logs, use a clean soft

paint brush as the logs are fragile and easily

damaged.

2) Clean (never when unit is hot) appliance,

door and louvers with a damp cloth. Never

use an abrasive cleaner. The fi nishes on

louvers and doors may be scratched if

abrasives are used to clean them. The

heater is fi nished in a heat resistant paint

and should only be refi nished with heat

resistant paint (not with wall paint). FPI uses

Never operate the appliance without the glass properly secured in place or with the door open.

7)Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water.

8)Periodically check the pilot fl ames. Correct

ame pattern has three strong blue fl ames: 1

owing around the thermopile and 1 around the thermocouple, and 1 fl owing across the front of the burner.

Note: If you have an incorrect flame pattern, contact your FPI dealer for further instructions.

2)Remove the Termination Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive condensation,suchaswaterdropletsforming in the inner liner, and subsequently dripping out the joints. Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints to verify that no pipe sections or fi ttings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

StoveBrite Paint - Metallic Black #6309.

3) Make a periodic check of the burner for

proper position and condition. Visually

check the fl ame of the burner periodically,

making sure the fl ames are steady: not

lifting or fl oating. If there is a problem, call

a qualifi ed service person.

4) The appliance and venting system must be

inspected before use, and at least annually,

by a qualifi ed fi eld service person, to ensure

that the fl ow of combustion and ventilation

air is not obstructed.

During the annual service call, the burners

should be removed and cleaned from the

burner tray.

Front Burner Tube

Top view of pilot flame

Incorrect fl ame pattern will have small, probably yellowflames,notcomingintopropercontactwith the rear of the burner or thermopile.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty.

5) Keep the area near the appliance clear and

free from combustible materials, gasoline

and other fl ammable vapours and liquids.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAYTOAVOIDBURNSORCLOTHING IGNITION. YOUNGCHILDRENSHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

6)Each time the appliance is lit, it may cause condensation and fog the glass. This condensation and fog is normal and will disappear in a few minutes as the glass heats up.

Front Burner Tube

Top View of pilot flame

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. Thesewillappearasrustspotsorstreaks,and in extreme cases, holes. These components should be replaced immediately.

GLASS GASKET

If the glass gasket requires replacement use a tadpole gasket for the Flush Front (Part # 936-155).

DOOR GLASS

Your FPI insert is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. Do not abuse the glass by striking the surface or by slamming the door shut.

If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized FPI dealer only, do not use substitute materials. Follow our step-by-step instructions for replacement. Warning: Wear gloves when removing damaged or broken glass.

Caution: Do not operate appliance with glass panels removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

MAINTENANCE

Regency® L234 Direct Vent Gas Insert

31

Image 31
Contents L234 Gas Insert Regency GAS Fireplace Insert Table of Contents Safety Label MA Code CO Detector RequirementsUnit & Faceplate Dimensions Installation Materials Required Installation ChecklistMinimum Fireplace Opening Minimum Clearances to Combustible Mantel Combustibles Venting Installation with 3 & 3 LinersConverting from 3 & 3 Venting to 3 Vent Restrictor PositionGAS Insert Aeration System Flue Liner GAS Connection InstallationSIT Valve Description GAS Pipe Pressure TestingSpring Hook Conversion KIT #536-969 from NG to LPTop Mounting Bracket Burner RemovedRemove burner orifice with a 1/2 wrench Optional Brick Panel Installation Contour or Contemporary Faceplate Faceplate Contents ListRemote Receiver Bracket DC SparkerCompleted Faceplate Installation Attach Top Backing Plate to Faceplate Optional Backing PlateAttach Faceplate & Top Backing Plate to Unit Attach Left & Right Backing Plate to Faceplate Attach Left & Right Corner Backing PlateCustomize Hearth Trim Optional Hearth Trim711 713 7152-716 712 714 LOG SET InstallationTab NotchRight side of Burner Completed Log Set Installation Wiring Diagrams Optional Wall Thermostat Optional Remote ControlFinal Check First Fire Lighting ProcedureShutdown Procedure Operating InstructionsFAN Operation Copy of Lighting Instruction PlateMaintenance FAN Replacement Connector Clips DC Sparker Wires Valve ReplacementValve Removed Main Assembly Parts ListFaceplate Assembly Backing Plate & Hearth Trim Assembly Conditions WarrantyInstaller Please complete the following information

L234-NG, L234-LP specifications

The Regency L234-LP and L234-NG are elegant and efficient gas fireplaces that exemplify modern design and advanced technology. These models are ideal for homeowners looking to enhance their living spaces with warmth and aesthetics. With a variety of features, the Regency L234 fireplace series stands out in both functionality and style.

One of the key characteristics of the L234 series is its choice between liquid propane (LP) and natural gas (NG) configurations, providing flexibility for various installation needs. This adaptability allows homeowners to select the fuel type that best suits their preferences and available resources.

In terms of design, the L234 fireplaces feature a contemporary clean face style, which emphasizes the stunning flames while minimizing distractions. The large viewing area is framed by a sleek, minimalist design that fits effortlessly into modern interiors. With customizable options, including different decorative media such as glass and stones, consumers can personalize the appearance of their fireplace to match their home decor.

Efficiency is another hallmark of the Regency L234 series. With its high-efficiency rating, this fireplace not only produces warmth but does so while minimizing fuel consumption. The incorporation of advanced technology such as a direct vent system allows for safe and efficient combustion, drawing in outdoor air for combustion and venting exhaust gases outside. This feature enhances the overall efficiency of the unit, ensuring the living space remains warm and comfortable.

The L234 also comes equipped with a user-friendly remote control, simplifying the operation and allowing users to adjust flame height and heat output from a distance. This remote capability enhances convenience and allows for immediate adjustments based on comfort levels.

Safety features are paramount in the design of the Regency L234 fireplaces. The units are equipped with automatic shut-off systems and advanced safety screens to prevent accidents, providing peace of mind to homeowners.

Overall, the Regency L234-LP and L234-NG gas fireplaces are exemplary choices for those seeking a blend of modern design, efficiency, and safety. With their customizable features and advanced technologies, they provide not only heating solutions but also a stylish focal point for any room. As homeowners seek eco-friendly alternatives that do not compromise on style, the Regency L234 series stands out as a top contender in the market.