Regency 510-994, 946-523/P P33-NG4 w P33-LP4 w Model, August 2008 Product Specifications Book

Page 2

Gas Fireplaces

 

 

 

 

P33-NG4 w/

 

P33-LP4 w/

Model

 

Contemporary

 

Contemporary

 

 

 

 

Faceplate

 

Faceplate

Fuel Type

 

Natural Gas

 

Propane

 

 

 

 

 

 

 

 

 

Minimum Supply Pressure

 

5” W.C. (1.25 kPa)

 

12” W.C. (3.00 kPa)

 

 

 

 

 

 

 

 

 

Manifold Pressure - High

 

3.8” W.C. (0.95 kPa)

 

11” W.C. (2.74 kPa)

 

 

 

 

 

 

 

 

 

Manifold Pressure - Low

 

1.1” W.C. (0.27 kPa)

 

3.3” W.C. (0.82 kPa)

 

 

 

 

 

 

 

 

 

Orifice Size

 

#47 DMS

 

#56 DMS

 

 

 

 

 

 

 

 

 

Minimum Input

 

9,800 BTU/h

 

9,000 BTU/h

Altitude 0-4500 ft. (0-1372m)

 

(2.87 kW)

 

(2.64 kW)

 

 

 

 

 

 

 

 

 

Maximum Input

 

17,500 BTU/h

 

15,500 BTU/h

Altitude 0-4500 ft. (0-1372m)

 

(5.13 kW)

 

(4.54 kW)

 

 

 

 

 

 

 

 

 

Vent Sizing

4” Inner / 6 5/8” Outer

 

4” Inner / 6 5/8” Outer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approved Venting Systems

 

Flex Vent Systems:

 

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

 

Simpson Direct Vent Pro®

 

 

 

 

American Metal Products® Amerivent Direct

 

 

 

 

Security Secure Vent®

 

 

 

 

 

Selkirk Direct-Temp™

 

 

 

 

 

Metal-Fab® Sure Seal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P33 Gas Fireplace

Gas Fireplaces

Unit Dimensions

Description

P33 with Contemporary Faceplate

A

Front Face Width

33” (838mm)

B

Rear Firebox Width

23” (584mm)

C

Front Face Height

29” (737mm)

D

Height w/ Standoff

31 1/2” (800mm)

E

Unit Depth

 

12-3/4” (324mm)

F

Firebox Height

29” (737mm)

 

 

 

 

 

 

Framing Dimensions

Description

 

P33 with Contemporary Faceplate

 

 

 

 

 

G

Framing Width

33-1/4” (845mm)

H**

Framing Height**

31-3/4” (806mm)**

I*

Framing Rise from Floor

1” (25mm) minimum*

J

Framing

 

Vertical

19 1/2” (495mm) Vertical Rise

 

 

 

 

 

 

Depth

 

Horizontal

16 1/2” (419mm) Rigid

 

12-3/4” (324mm) Flex

 

 

 

 

 

 

 

K

Corner Wall Length

37 1/2” (953mm)

L

Corner Facing Wall Width

53-1/4” (1353mm)

M***

Framed Chase Ceiling***

36” (914mm) Rigid***

 

32” (813mm) Flex***

 

N

Vent Centerline Height

30” (762mm) Rigid

 

26” (660mm) Flex

 

 

 

 

 

 

 

*The unit must be raised a minimum of 1” above the finished floor.

**Dimension H = H + I (minimum)

***Dimension M = M + I (minimum)

Dimension

Description

P33S

 

 

 

O

Gas Connection Height

1 1/2” (38mm)

P

Gas Connection Inset

4” (102mm)

Q

Gas Connection Width

3” (76mm)

R

Minimum Framing Depth

16 1/2” (419mm) Rigid

/

12-3/4” (324mm) Flex

S

Maximum Framing Depth

40 1/2” (1028mm) Rigid

/

36-3/4” (933mm) Flex

(including wall thickness)

 

 

 

 

 

 

 

 

 

Important:

If the Contemporary Faceplate is used on the P33-NG4/P33- LP4 Gas Fireplace, the burner orifice (Both NG/LP supplied in package) must be replaced and an overlay decal (also supplied with kit) must be affixed to the current serial number decal supplied with unit.

Note: Also see framing dimensions for this optional front if installed on the P33-4 unit.

Note: Unit must be raised up by 1' to allow for faceplate installation.

 

NG

LP

Current P33-4 orifice size: #44

#54

Must replace with:

#47

#56

Warning: Fire hazard is an extreme risk if these changes are not adhered to.

August 2008 Product Specifications Book

29

Image 2
Contents Approved Venting Systems Model P33-NG4 P33-LP4August 2008 Product Specifications Book Contemporary Faceplate P33-NG4 w P33-LP4 w ModelAugust 2008 Product Specifications Book Combustible Mantels Framing and FinishingClearance Requirements Mantel Leg ClearancesFlue Clearances to Combustibles Clearance Dimension Measured FromMantel Leg Clearances with Contemporary Faceplate Horizontal Terminations Only FPI Direct Vent System FlexSnorkel Terminations Snorkel TerminationsAlternate Horizontal Termination Caps Rigid Pipe VentingVenting Arrangements Vertical Terminations Horizontal or Vertical TerminationsElbows is required OptionMinimum of 1 foot between Option + H1Venting Arrangements Horizontal Terminations Vent Termination LocationsElbows is MinimumFoot between RequiredAlternate Approved Caps Vertical termination with co-linear flex systemRequired Parts Description