Gas Fireplaces
Venting Arrangements - Horizontal
Terminations
This lightly shaded area of the diagram shows allowable combinations of vertical runs with horizontal terminations, using one 45° and one 90° elbow (two 45º elbows equal one 90° elbow).
Note: Must use optional rigid pipe adapter (Part #
P33 Gas Fireplace
•Maintain clearances to combustibles.
•Horizontal vent must be supported every 3 feet.
•Firestops are required at each floor level and whenever passing through a wall.
A vent guard may be required as per local codes, refer to Exterior
Vent Termination Locations.
Note: FPI Direct Vent System (Flex) is only approved for horizontal terminations.
*Unit must be raised by 1” when using Contemporary Faceplate
Please refer to Exterior Vent Terminations for
additional guidelines on vent locations.
Gas Fireplaces
August 2008 Product Specifications Book | 35 |