Regency Comprehensive Guide to Indoor Fireplace Specifications and Features

Page 1

Gas Fireplaces

Gas Fireplaces

P33 Gas Fireplace

P33 Zero Clearance Direct Vent Gas Fireplace

P33 WITH THE FLUSH OR BAY FRONT

Model

 

 

P33-NG4

 

P33-LP4

 

Fuel Type

 

 

Natural Gas

 

Propane

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Supply Pressure

 

 

5” W.C. (1.25 kPa)

 

12” W.C. (3.00 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

Manifold Pressure - High

 

 

3.8” W.C. (0.95 kPa)

 

11” W.C. (2.74 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

Manifold Pressure - Low

 

 

1.1” W.C. (0.27 kPa)

 

3.3” W.C. (0.82 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

Orifice Size

 

 

#44 DMS - 0-2000ft

 

#54 DMS

 

 

#45 DMS - 2000-4500ft

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Input

 

 

12,500 BTU/h

 

 

 

Altitude 0-2000 ft. (0-610m)

 

 

(3.66 kW)

 

10,500 BTU/h

 

 

 

 

 

 

 

 

 

 

 

Minimum Input

 

 

10,500 BTU/h

 

(3.07 kW)

 

 

 

 

 

 

Altitude 2000-4500 ft. (610-1372m)

 

 

(3.07 kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Input

 

 

22,500 BTU/h

 

 

 

Altitude 0-2000 ft. (0-610m)

 

 

(6.59 kW)

 

21,500 BTU/h

 

 

 

 

 

 

 

 

 

 

 

Maximum Input

 

 

21,000 BTU/h

 

(6.30 kW)

 

 

 

 

 

 

Altitude 2000-4500 ft. (610-1372m)

 

 

(6.15 kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent Sizing

 

4” Inner / 6 5/8” Outer

 

4” Inner / 6 5/8” Outer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approved Venting Systems

 

 

Flex Vent Systems:

 

FPI AstroCap™ Flex Vent

 

 

 

 

 

Rigid Pipe Vent Systems:

 

Simpson Direct Vent Pro®

 

 

 

 

 

 

American Metal Products® Amerivent Direct

 

 

 

 

 

 

Security Secure Vent®

 

 

 

 

 

 

 

Selkirk Direct-Temp™

 

 

 

 

 

 

 

Metal-Fab® Sure Seal

 

 

 

 

 

 

 

B

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

C D

F

 

 

 

 

A

 

E

Unit Dimensions

Description

 

P33

A

Front Face Width

 

33” (838mm)

B

Rear Firebox Width

 

23” (584mm)

C

Front Face Height

 

29” (737mm)

D

Height w/ Standoff

 

31 1/2” (800mm)

H

G

J

Top Header

Drywall (or other facing)

10" (254mm) dia. Hole through

wall Vent.

I

M

Q

R

N

E

Unit Depth

 

12-3/4” (324mm)

F

Firebox Height

28 1/2” (724mm)

 

 

 

 

 

 

 

Framing Dimensions

Description

 

 

P33

 

 

 

 

 

G

Framing Width

33-1/4” (845mm)

H***

Framing Height***

31-3/4” (806mm)***

I

Framing

 

Vertical

19 1/2” (495mm) Vertical Rise

 

 

 

 

 

 

Depth

 

Horizontal

16 1/2” (419mm) Rigid

 

12-3/4” (324mm) Flex

 

 

 

 

 

 

 

J

Corner Wall Length

37 1/2” (953mm)

K

Corner Facing Wall Width

53-1/4” (1353mm)

L

Framed Chase Ceiling

36” (914mm) Rigid

 

32” (813mm) Flex

 

M

Vent Centerline Height

30” (762mm) Rigid

 

26” (660mm) Flex

 

 

 

 

 

 

 

***Important: Framing height requires consideration of the hearth depth. Dimension H = H + the thickness of installed hearth.

 

 

 

K

 

 

O

 

P

 

 

 

 

 

 

Opening for gas

 

 

 

 

 

 

connection

 

 

 

 

Dimension

Description

 

P33

 

 

 

 

N

Gas Connection Height

 

1 1/2” (38mm)

O

Gas Connection Inset

 

4” (102mm)

P

Gas Connection Width

 

3” (76mm)

Q

Minimum Framing Depth

 

16 1/2” (419mm) Rigid

/

12-3/4” (324mm) Flex

R

Maximum Framing Depth

 

40 1/2” (419mm) Rigid

/

36-3/4” (324mm) Flex

(including wall thickness)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please refer to Exterior Vent Terminations for

additional guidelines on vent locations.

28

August 2008 Product Specifications Book

Image 1
Contents August 2008 Product Specifications Book Model P33-NG4 P33-LP4Approved Venting Systems August 2008 Product Specifications Book P33-NG4 w P33-LP4 w ModelContemporary Faceplate Clearance Requirements Framing and FinishingCombustible Mantels Mantel Leg ClearancesMantel Leg Clearances with Contemporary Faceplate Clearance Dimension Measured FromFlue Clearances to Combustibles Snorkel Terminations FPI Direct Vent System FlexHorizontal Terminations Only Snorkel TerminationsVenting Arrangements Vertical Terminations Rigid Pipe VentingAlternate Horizontal Termination Caps Horizontal or Vertical TerminationsMinimum of 1 foot between OptionElbows is required Option + H1Vent Termination Locations Venting Arrangements Horizontal TerminationsFoot between MinimumElbows is RequiredRequired Parts Description Vertical termination with co-linear flex systemAlternate Approved Caps