Regency 946-523/P FPI Direct Vent System Flex, Snorkel Terminations, Horizontal Terminations Only

Page 5

Gas Fireplaces

P33 Gas Fireplace

FPI Direct Vent System (Flex)

Horizontal Terminations Only

This venting system, in combination with the P33 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram, see manual.

FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the P33 using a flexible vent.

FPI Kit #

Length

Contains:

#946-513

2 Feet

1)

6-5/8” flexible liner (Kit length)

 

 

2)

4” flexible liner (Kit length)

 

 

3)

spring spacers (3)

#946-515

4 Feet

4)

thimble (2)

 

 

5)

AstroCap termination cap (1)

Gas Fireplaces

Important

When installing Cabinet Mantels: the wall thimble must be secured first and venting must be attached to unit before sliding into final position.

Snorkel Terminations

Snorkel Terminations:

For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall Snorkel Terminations and the Riser Vents are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down.

 

 

6)

screws (12)

#946-516

10 Feet

7)

tube of Mill Pac (1)

 

 

8)

plated screws (8)

 

 

9)

S.S. screws #8 x 1-1/2” drill point, (4)

Notes:

1)Liner sections should be continuous without any joints or seams.

2)Only Flex pipe purchased from Regency may be used for Flex installations.

3)Horizontal sections must be supported every 3 feet.

Dura-Vent

Snorkel

Min. 12"*

(305mm)

Riser Vent

Termination

Min. 6-1/4"*

(159mm)

 

Wall Thimble (2 pc)

4" (102mm)

AstroCapTM

Termination Cap

dia. flue pipe

(Part# 946-523/P)

spring spacer

6-7/8"

(173mm) dia. Flue pipe

Alternate Horizontal

Termination Caps

If required by the external termination location the listed alternate termination caps may be used.

Below Grade Snorkel Installation (Dura-Vent Only)

If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Rigid Pipe Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure.

Dura-Vent

 

Snorkel

 

Min.12"*

(305mm)

Window

Well

 

Adequate

 

drainage

 

Gravel

 

32

August 2008 Product Specifications Book

Image 5
Contents Approved Venting Systems Model P33-NG4 P33-LP4August 2008 Product Specifications Book Contemporary Faceplate P33-NG4 w P33-LP4 w ModelAugust 2008 Product Specifications Book Clearance Requirements Framing and FinishingCombustible Mantels Mantel Leg ClearancesFlue Clearances to Combustibles Clearance Dimension Measured FromMantel Leg Clearances with Contemporary Faceplate Snorkel Terminations FPI Direct Vent System FlexHorizontal Terminations Only Snorkel TerminationsVenting Arrangements Vertical Terminations Rigid Pipe VentingAlternate Horizontal Termination Caps Horizontal or Vertical TerminationsMinimum of 1 foot between OptionElbows is required Option + H1Vent Termination Locations Venting Arrangements Horizontal TerminationsFoot between MinimumElbows is RequiredAlternate Approved Caps Vertical termination with co-linear flex systemRequired Parts Description