Regency 946-523/P Minimum of 1 foot between, Elbows is required, Option + H1, Is required

Page 7

Gas Fireplaces

P33 Gas Fireplace

Vertical Venting with Two (2) 90° Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V

H

V+ V1

Maximum total pipe: length, of

 

 

 

 

all sections, must not exceed

A)

1’ Min.

4’ Max.

2’ Min.

30 feet.

 

 

 

 

B)

2’ Min.

5’ Max.

3’ Min.

Total horizontal sections must

 

 

 

 

not exceed 8 feet.

C)

3’ Min.

6’ Max.

4’ Min.

Minimum of 1 foot between

 

 

 

 

D)

4’ Min.

7’ Max.

5’ Min.

90° elbows is required.

E)

5’ Min.

8’ Max.

6’ Min.

 

 

 

 

 

 

Vertical Venting with Two (2) 90° Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H + H1

V

Maximum total pipe: length, of

 

 

 

all sections, must not exceed

A)

2’ Max.

2’ Min.

30 feet.

 

 

 

B)

3’ Max.

3’ Min.

Total horizontal sections must

 

 

 

not exceed 6 feet.

C)

4’ Max.

4’ Min.

Minimum of 1 foot between

 

 

 

D)

5’ Max.

5’ Min.

90° elbows is required.

 

 

 

 

E)

6’ Max.

6’ Min.

 

 

 

 

 

34

Gas Fireplaces

Vertical Venting with Three (3) 90° Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V

H + H1

V+ V1

Maximum total pipe: length, of

 

 

 

 

all sections, must not exceed

A)

2’ Min.

3’ Max.

4’ Min.

30 feet.

 

 

 

 

B)

3’ Min.

4’ Max.

6’ Min.

Total horizontal sections must

 

 

 

 

not exceed 8 feet.

C)

4’ Min.

5’ Max.

7’ Min.

Minimum of 1 foot between

 

 

 

 

D)

5’ Min.

6’ Max.

8’ Min.

90° elbows is required.

E)

6’ Min.

7’ Max.

9’ Min.

 

 

 

 

 

 

F)

7’ Min.

8’ Max.

10’ Min.

 

Vertical Venting with Three (3) 90° Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H

V

H + H1

V+ V1

Maximum total pipe:

 

 

 

 

 

length, of all sections,

A)

1’ Max.

1’ Min.

3’ Max.

3’ Min.

must not exceed 30

 

 

 

 

 

feet.

B)

2’ Max.

2’ Min.

4’ Max.

5’ Min.

Total horizontal sections

 

 

 

 

 

must not exceed 7

C)

3’ Max.

3’ Min.

5’ Max.

7’ Min.

feet.

 

 

 

 

 

 

 

 

 

 

Minimum of 1 foot

D)

4’ Max.

4’ Min.

6’ Max.

9’ Min.

between 90° elbows

 

 

 

 

 

E)

5’ Max.

5’ Min.

7’ Max.

11’ Min.

is required.

 

 

 

 

 

 

August 2008 Product Specifications Book

Image 7
Contents August 2008 Product Specifications Book Model P33-NG4 P33-LP4Approved Venting Systems August 2008 Product Specifications Book P33-NG4 w P33-LP4 w ModelContemporary Faceplate Mantel Leg Clearances Framing and FinishingClearance Requirements Combustible MantelsMantel Leg Clearances with Contemporary Faceplate Clearance Dimension Measured FromFlue Clearances to Combustibles Snorkel Terminations FPI Direct Vent System FlexSnorkel Terminations Horizontal Terminations OnlyHorizontal or Vertical Terminations Rigid Pipe VentingVenting Arrangements Vertical Terminations Alternate Horizontal Termination CapsOption + H1 OptionMinimum of 1 foot between Elbows is requiredVent Termination Locations Venting Arrangements Horizontal TerminationsRequired MinimumFoot between Elbows isRequired Parts Description Vertical termination with co-linear flex systemAlternate Approved Caps