8 – Arranque, Apagado y Derivación

1

8-1 Diagramas del Panel de Control e Interruptor de Circuitos

A

LED “NORMAL” [En Línea]

 

LED “BATTERY” [Batería]

B

 

LED “BYPASS” [Derivación]

C

 

LED “FAULT” [Falla]

D

 

Pantalla LCD de Estado

E

 

Botón “ESC” (Escape)

F

 

Botones de Recorrido ( y )

G

 

Botón Entrar ( )

H

 

Botón de Encendido

I

 

Botón de Apagado

J

 

Botón “EPO” (Apagado de Emergencia)

K

 

Interruptor de Circuitos de Salida

L

 

Interruptor de Circuitos de Derivación Manual

M

 

Interruptor de Circuitos de Entrada de Derivación

N

 

Interruptor de Circuitos de la Entrada Principal

O

 

E

F

I

K

2

 

A

 

 

 

 

B

G

 

 

 

 

C

 

 

 

 

 

 

 

 

 

D

 

 

 

3

 

 

 

 

 

 

 

H

J

 

 

 

O

O

 

O

4

 

OFF

OFF

 

OFF

 

O

 

 

 

 

 

OFF

 

 

 

 

 

Main

 

 

 

 

 

Input

 

 

 

 

 

Entrada

Entrada de

Derivación

Salida

5

Principal

Derivción

Manual

 

O

N

M

 

L

 

Panel Frontal

Panel Trasero

 

Interruptores de los Interruptores de Circuito

6

8-2 Lista de Control Preliminar (Un Solo UPS)

Todos los interruptores de los interruptores de circuito deben estar apagados, incluyendo el interruptor de circuitos del gabinete de baterías externas (si lo hubiera).

Confirme que no existen voltajes potenciales entre el Neutro y la Tierra.

Confirme que la fuente de energía de entrada tenga los mismos valores (voltaje, frecuencia y fase) que los del sistema UPS.

Nota: Después del arranque, el sistema UPS efectuará una breve auto prueba y mostrará los resultados en la pantalla LCD. Después de una auto prueba exitosa, el sistema UPS suministrará energía CA a la carga de los equipos conectados.

7

8

8-3 Procedimiento de Arranque Normal (Un Solo UPS)

1 Si hay un gabinete de baterías externas conectado, encienda el interruptor de circuitos A del gabinete de baterías externas.

2 Confirme que el interruptor de circuitos de derivación manual A está apagado.

 

 

 

9

 

A

 

 

 

 

 

10

1

 

 

11

 

 

 

 

O

O

O

 

OFF

OFF

OFF

O

 

 

 

OFF

 

 

 

Main

 

 

12

Input

 

 

 

Entrada

Entrada de

Derivación

Salida

Principal

Derivción

Manual

 

 

 

A

13

 

 

 

2

Panel Frontal

Panel Trasero

67

200803004 93-2793 SU80k manual 4C.indd S67

6/16/2008 1:44:21 PM

Page 67
Image 67
Tripp Lite SU80K owner manual Arranque, Apagado y Derivación, Diagramas del Panel de Control e Interruptor de Circuitos

SU80K specifications

The Tripp Lite SU80K is a robust and reliable uninterruptible power supply (UPS) solution, designed to provide essential backup power to critical equipment in various environments such as data centers, telecommunications, and industrial settings. This high-capacity UPS offers 80 kVA of power, ensuring optimal protection for vital systems against power interruptions and fluctuations.

One of the main features of the SU80K is its advanced double-conversion technology, which provides clean and consistent power by converting incoming AC power to DC and then back to AC. This process not only isolates connected equipment from raw utility power, but it also ensures that sensitive electronic devices maintain a steady voltage and frequency, ultimately enhancing their performance and lifespan.

In terms of efficiency, the SU80K is equipped with an energy-efficient design that maximizes operation while minimizing energy consumption. The unit operates with an efficiency rating of up to 97% in online mode, which contributes to reduced operational costs over time and is especially beneficial for large-scale deployments.

Another notable characteristic of the SU80K is its modular design, which allows for flexibility and scalability. Users can add additional battery packs to extend runtime, enabling the UPS to adapt to changing power needs without requiring complete system replacement. This feature is particularly advantageous for growing businesses that need to expand their backup power capabilities progressively.

The SU80K also includes advanced monitoring and management options, with an optional network management card that enables remote monitoring via a web interface. This capability provides real-time data on the UPS’s status, battery health, and load levels, allowing IT administrators to make informed decisions to maintain system availability.

Additionally, the UPS features multiple communication ports, including RS-232 and USB interfaces, ensuring compatibility with various devices and ease of integration into existing systems. It also supports SNMP protocols, allowing for seamless integration with network management systems.

Overall, the Tripp Lite SU80K combines high performance, advanced features, and user-friendly management options to create an ideal solution for businesses that require reliable and efficient power protection for their critical equipment. With its strong build quality and commitment to performance, the SU80K stands out as a versatile choice for ensuring business continuity in the face of power disturbances.