Weil-McLain EGH-125, EGH-105 manual CSD-1 control panel

Page 17

Part Number 550-110-677/0299

1

CSD-1 control panel

 

 

2

Ignition control

 

 

3

Impulse relay and lighted push-button alarm

silencing switch

 

 

 

4

Terminal strip

 

 

5

Transformer/relay

 

 

6

Junction box

 

 

7

Damper (optional)

 

 

8

Damper connector

 

 

9

Dummy plug

 

 

10

Damper harness

 

 

11

Main gas valve

 

 

12

Manual gas valve

 

 

13

Pilot gas valve

 

 

13a

Pilot gas pressure regulator

 

 

14Pilot shutoff valve

15Leak test valves with plugs

16Gas supply connection

17Burner manifold

18Limit control, automatic reset

19Limit control, manual reset

20Pressure gauge

21Siphons

22Gauge glass & valves

23Probe LWCO, manual reset

24Float LWCO control, automatic reset

25Wire harness

26Pilot spark & sense wires

27Pilot gas tubing

EGH-105 to EGH-125 Control Supplement

CSD-1 control system — Natural gas

17

Image 17
Contents Control Supplement Please read this page first Boiler cartons Carton guideGas train assembly InstallationVent damper assemblies Install optional vent damper if suppliedWater boiler connections III Install boiler controls water boilersII Piping connections Steam boiler connections III Install boiler controls steam boilersIV Optional heaters steam boilers only Gas piping VI WiringCall for heat VI Wiring sequence of operationWater boiler wiring Wiring water boilersSchematic Wiring Diagram Control assembly water boiler VI Wiring water boilersCSD-1 control panel Gravity return VI Wiring steamSchematic Wiring Diagram 13a Control assembly steam, gravity returnCSD-1 control panel Pumped return Schematic Wiring Diagram Control assembly steam, pumped return Terminal strip Before proceeding To place boiler in operation VII Final adjustmentsOperating instructions VII Final adjustments operating instructionsViii Check-out procedure operation Leak test procedure Viii Check-out procedure leak testVerify proper operation after servicing Viii Check-out procedure troubleshootingReplace pilot assembly TS-2 No Spark System boiler with vent damper does not work Not OK TS-3 Pilot lights Main valve will not come on from previous IX Service and maintenance Water boiler assembly Replacement parts water boilersRV20VL Water boiler replacement partsSteam boiler assembly Replacement parts steam boilersRV20VL Steam boiler replacement partsWeil-McLain Blaine Street Michigan City,