PB Heat WV Series manual Heating, Water Content, Capacity, Input, Net I=B=R Ratings4 Gal Draft

Page 22

BOILER DIMENSIONS & RATINGS

Table 7.1: Boiler Ratings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Series WBV/WV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

Minimum

 

 

 

 

 

5

,

 

 

 

AFUE,

 

Water Content,

 

 

 

 

Capacity

 

 

 

 

Stack

 

 

Input

MBH

 

Net I=B=R Ratings4

 

%

 

 

gal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Draft

 

Model

 

 

 

 

 

 

Steam,

Steam,

Water,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Required,

 

Number

GPH¹

MBH

Water

 

Steam

sqft

MBH³

MBH²

Water

 

Steam

 

Water

 

Steam

in. W.C.

 

WBV-03

0.60✚✪

84

75

 

65

87.5

 

 

11.75

 

-0.03

 

WBV-03

0.85

119

104

 

103

321

77

90

86.2

 

84.8

 

11.75

 

12.00

-0.04

 

WBV-03

1.05

147

126

 

124

388

93

110

85.0

 

83.6

 

11.75

 

12.00

-0.05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WBV-04

0.95

133

117

 

102

87.0

 

 

14.75

 

-0.03

 

WBV-04

1.25

175

151

 

151

471

113

131

85.4

 

85.3

 

14.75

 

14.87

-0.04

 

WBV-04

1.50

210

180

 

179

558

134

156

85.1

 

84.3

 

14.75

 

14.87

-0.05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WV-05

1.75

245

212

 

184

85.5

 

 

17.75

 

-0.05

 

WV-05

1.95

273

235

 

204

85.0

 

 

17.75

 

-0.06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

As an ENERGY STAR® Partner, PB Heat, LLC has determined that these firing rates meet the ENERGY STAR guidelines for energy efficiency. Top venting only.

Nozzles for these firing rates not provided as standard equipment. Consult factory for price and availability. This firing rate can only be achieved with a Riello F-3 burner. See Table 5.3.

1 Burner input based on No. 2 fuel oil with a heating value of 140,000 Btu per gallon.

2 Net I=B=R water ratings based on an allowance of 1.15.

3 Net I=B=R steam ratings based on an allowance of 1.333.

4 Consult factory before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.

5 Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) ratings are based on U.S. Government tests, with 13% CO2 and –0.02" w.c. draft over fire. Before purchasing this appliance, read important information about its estimated annual energy consumptions or energy efficiency rating that is available from your retailer.

6 Chimney Size: 8" x 8" x 15 ft.

20

Image 22
Contents Series WBV/WV Table of Contents Installation Clearance Using this ManualSpecial Attention Boxes AIR for Combustion and Ventilation PreinstallationClearances Required from Jacket Recommended From Jacket forPlanning the Layout Installation SurveyChimney / Vent and Draft Control Old New CommentsConnecting the Flue Outlet Boiler Placement and AssemblySetting the Boiler Jacket Assembly Knockdown BoilersSteam boiler Boiler Return Clearance Pressure Test Block AssemblyPiping and Controls Water Boiler PipingTankless Heater or Coverplate ControlsFloat Low Water Cut-off Electrical Burner WiringGeneral Water Boilers, Knockdown Steam with Float Low Water Cut-Off Zoning with Circulators Burner START-UP and Adjustment Burner Setup & Boiler OperationBurner Installation Check Boiler ControlsClean the Boiler Steam Boilers only Cleaning the boiler requires the useDEL Hago85 x 60 B Hago 65 60 B HagoMaintenance Maintenance of Safety Relief Valve Daily Maintenance with Boiler OperatingWeekly Maintenance with Boiler Operating Monthly Maintenance with Boiler OperatingIf a Long Shutdown is Required Opened to facilitate this operationDepth Boiler Dimensions & RatingsBoiler Jacket Rear of Jacket to Top Boiler Jacket Rear of Jacket toCapacity Water ContentHeating InputRepair Parts Item No Stock Code Description Additional InformationPage Page Series WBV/WV