ATTIX 9 H/M
8 Troubleshooting
| Fault |
|
| Cause |
|
| Remedy |
|
‡ Motor does not start | > | Fuse of the mains socket has | • | Connect mains fuse. |
| |||
|
|
|
| blown. |
|
|
|
|
|
|
| > | Overload protection switch | • | Switch off the vacuum cleaner | ||
|
|
|
| has tripped. |
| and allow it to cool for approx. | ||
|
|
|
|
|
| 5 minutes. If the cleaner |
| |
|
|
|
|
|
| cannot be started again, |
| |
|
|
|
|
|
| contact the | ||
|
|
|
|
|
| department. |
| |
|
|
| > | Motor is faulty. | • | Have motor changed by |
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
| |||
‡ Motor does not run in | > | Power tool/pneumatic tool is | • | Check that the power tool |
| |||
| automatic mode 1) |
|
| defective or not connected |
| works or that the plug is |
| |
|
|
|
| properly. |
| inserted correctly. |
| |
|
|
| > The power rating of the | • | Note that minimum power |
| ||
|
|
|
| electrical tool is too low. |
| rating is P>40W |
| |
|
|
|
|
|
|
|
| |
‡ | The acoustic | warning | > | Suction power selected with | • | Set suction power in |
| |
| sounds. (Reduced | suction |
| suction power control is too |
| accordance with section |
| |
| power) |
|
| low. |
| „Setting suction power“. |
| |
|
|
| > | Hose diameter does not cor- | • | Set correct switch position for | ||
|
|
|
| respond with switch position. |
| hose diameter. |
| |
|
|
| > | Clogged suction hose/nozzle. | • | Clean suction hose/nozzle |
| |
|
|
| > The safety filter bag is full. | • | See section „Replacing the fil- | |||
|
|
|
|
|
| ter bag“. |
|
|
|
|
| > Filter element is clogged. | • | See section „Cleaning filter | |||
|
|
|
|
|
| element“ and „Replacing filter | ||
|
|
|
|
|
| element“. |
| |
|
|
| > | Cleaning mechanism is | • | Contact | ||
|
|
|
| defective. |
|
|
|
|
|
|
|
|
| ||||
‡ No suction power during | > | Tank is full. | • | Switch off the cleaner. Empty | ||||
| wet cleaning |
|
|
|
| the tank. |
|
|
|
|
|
|
|
| |||
‡ | Voltage fluctuations | > | Impedance of power supply is | • | Connect the cleaner to another | |||
|
|
|
| too high. |
| socket closer to the fuse box. | ||
|
|
|
|
|
| Voltage | fluctuations | over |
|
|
|
|
|
| 7% should not occur if the | ||
|
|
|
|
|
| impedance at the transfer point | ||
|
|
|
|
|
| is ≤ 0.15 Ω . |
| |
|
|
|
|
|
|
|
|
|
26 | 1) Optional accessories / Option depending on model |
| Original Instructions |