Nilfisk-ALTO ATTIX 965-2H/M SD XC, ATTIX 965-0H/M SD XC manual Transport, Storage

Page 4

ATTIX 9 H/M

Dust Class M (medium). The dusts which belong to this class are: dusts with OEL values1) > 0.1 mg/m³ as well as saw dust. The machine is tested in its entirety by vacuums for this dust

class. The maximum degree of permeability is 0.1% and the dis-

 

posal must be low dust.

 

 

 

 

 

 

 

 

 

Dust Class H (high). The dusts which belong to this class are:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dusts with OEL values1), all carcinogenic dusts and dusts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

which are mixed with pathogenic agents. Vacuums for Dust

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Class H are tested in their entirety and have a maximum degree of

 

permeability of 0.005%. The disposal must be dust free.

 

The air flow in Safety Vacuum systems has to be strictly controlled to

 

achieve a minimum flow rate of Vmin = 20 m/s in the suction hose.

 

The vacuum cleaners ATTIX 965-0H/M SD XC and ATTIX 965-2H/

 

M SD XC are suitable to pick up

 

• dry, nonflammable dust, non flammable liquids, sawdust and haz-

 

 

 

ardous dusts with OEL values1), carcinogenic dusts, dusts contain-

 

 

 

ing germs

 

When dust removers are used, the rate at which air is exchanged

 

in the room must be adequate if the exhaust air from the vacuum

 

cleaner is blown into the room (please observe regulations valid in

 

your country).

 

The vacuum cleaner is suitable for commercial use, such as e.g. in

 

• Hotels, Schools, Hospitals, Factories, Shops, Offices, Hire shops

 

Any other use is considered as improper use. The manufacturer ac-

 

cepts no liability for any damage resulting from such use. The risk for

 

such use is borne solely by the user.

 

Proper use also includes proper operation, servicing and repairs as

 

specified by the manufacturer.

Transport

1. Before transporting the dirt tank, close all the locks.

 

2. Make sure that both plugs are inserted in fittings.

 

3. Do not tilt the cleaner if there is liquid in the dirt tank.

 

4. Do not use a crane hook to lift the cleaner.

Storage

1. Store the appliance in a dry place, protected from frost.

1) OEL = Occupational Exposure Limit

3

Original Instructions

 

Image 4
Contents Operating Instructions Contents Important safety instructions Symbols used to markTransport StorageMaintenance, cleaning Electrical connectionExtension lead Cable length Cross section 16 a 25 aOEL = Occupational Exposure Limit Original Instructions Risks Electrical components Picking up liquidsAttix 9 H/M Description Operating elementsOperating panel Before starting the cleaner Before starting the cleaner Inserting the safety filter bagOptional accessories / Option depending on model Inserting the disposal bag Optional accessories / Option depending on model Control / Operation Auto-On/Off-Operation auto switch position Check volume flow monitor Acoustic warning Cleaning the filter elementTechniques Applications and methodsPicking up dry Substances After using the cleaner Switching the vacuum cleaner off and storageMaintenance Maintenance plan After finishing work When requiredRemoving the dirt tank Maintenance work 7.2.1 Emptying the dirt tankInserting the dirt tank Replacing the disposal bag Removing the disposal bagReplacing the safety filter bag Removing the safety filter bagReplacing filter element H Remove the filter elementInserting the filter element Troubleshooting Fault Cause RemedyFurther information GuaranteeEC declaration of conformity Technical data Optional accessoriesHead Quarter